Blood clot fracture properties are dependent on red blood cell and fibrin content
Source abstract
Abstract
Thrombus fragmentation during endovascular stroke treatment, such as mechanical thrombectomy, leads to downstream emboli, resulting in poor clinical outcomes. Clinical studies suggest that fragmentation risk is dependent on clot composition. This current study presents the first experimental characterization of the composition-dependent fracture properties of blood clots, in addition to the development of a predictive model for blood clot fragmentation. A bespoke experimental test-rig and compact tension specimen fabrication has been developed to measure fracture toughness of thrombus material. Fracture tests are performed on three physiologically relevant clot compositions: a high-fibrin clot made from a 5% haematocrit (H) blood mixture, a medium-fibrin clot made form a 20% H blood mixture, a low-fibrin clot made from a 40% H blood mixture. Fracture toughness is observed to significantly increase with increasing fibrin content, i.e. red blood cell-rich clots are more prone to tear during loading compared to the fibrin-rich clots. Results also reveal that the mechanical behaviour of clot analogues is significantly different in compression and tension. Finite element cohesive zone modelling of clot fracture experiments show that fibrin fibres become highly aligned in the direction perpendicular to crack propagation, providing a significant toughening mechanism. The results presented in this study provide the first characterization of the composition-dependent fracture behaviour of blood clots and are of key importance for development of next-generation thrombectomy devices and clinical strategies. STATEMENT OF SIGNIFICANCE: This study provides a characterisation of the composition-dependent fracture toughness of blood clots. This entails the development of novel experimental techniques for fabrication and testing of blood clot compact tension fracture specimens. The study also develops cohesive zone models of fracture initiation and propagation in blood clots. Results reveal that the fracture resistance of fibrin-rich clots is significantly higher than red blood cell rich clots. Simulations also reveal that stretching and realignment of the fibrin network should be included in blood clot material models in order to accurately replicate compression-tension asymmetry and fibrin enhanced fracture toughness. The results of this study have potentially important clinical implications in terms of clot fracture risk and secondary embolization during mechanical thrombectomy procedures.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Acute Ischemic Stroke Management · Venous Thromboembolism Diagnosis and Management · Blood Coagulation and Thrombosis Mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (79)
Show source-provided references
1. 2016
2. Mechanical behavior of in vitro blood clots and the implications for acute ischemic stroke treatment
3. Stent-retriever thrombectomy after intravenous t-PA vs. t-PA alone in stroke10.1056/NEJMoa1415061 ↗
4. Trevo versus Merci retrievers for thrombectomy revascularisation of large vessel occlusions in acute ischaemic stroke (TREVO 2): A randomised trial10.1016/S0140-6736(12)61299-9 ↗
5. Single-center experience with a novel mechanical thrombectomy device10.1111/j.1552-6569.2011.00666.x ↗
6. Endovascular therapy for ischemic stroke with perfusion-imaging selection10.1056/NEJMoa1414792 ↗
7. Safety and efficacy of a 3-dimensional stent retriever with aspiration-based thrombectomy vs aspiration-based thrombectomy alone in acute ischemic stroke intervention: a randomized clinical trial10.1001/jamaneurol.2017.3967 ↗
8. A randomized trial of intraarterial treatment for acute ischemic stroke10.1056/NEJMoa1411587 ↗
9. Thrombectomy 6 to 24 hours after stroke with a mismatch between deficit and infarct10.1056/NEJMoa1706442 ↗
10. Solitaire flow restoration device versus the Merci Retriever in patients with acute ischaemic stroke (SWIFT): a randomised, parallel-group, non-inferiority trial10.1016/S0140-6736(12)61384-1 ↗
11. Endovascular therapy for acute ischaemic stroke: the pragmatic ischaemic stroke thrombectomy evaluation (PISTE) randomised, controlled trial10.1136/jnnp-2016-314117 ↗
12. Thrombectomy for stroke at 6 to 16 hours with selection by perfusion imaging10.1056/NEJMoa1713973 ↗
13. Mechanical thrombectomy after intravenous alteplase versus alteplase alone after stroke (THRACE): a randomised controlled trial10.1016/S1474-4422(16)30177-6 ↗
14. Endovascular thrombectomy after large-vessel ischaemic stroke: a meta-analysis of individual patient data from five randomised trials10.1016/S0140-6736(16)00163-X ↗
15. REVASCAT: a randomized trial of revascularization with SOLITAIRE FR® device vs. best medical therapy in the treatment of acute stroke due to anterior circulation large vessel occlusion presenting within eight-hours of symptom onset10.1111/ijs.12157 ↗
16. Effect of endovascular contact aspiration vs stent retriever on revascularization in patients with acute ischemic stroke and large vessel occlusion: the ASTER randomized clinical trial10.1001/jama.2017.9644 ↗
17. Maximizing first-pass complete reperfusion with SAVE10.1007/s00062-017-0566-z ↗
18. Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs10.3174/ajnr.A2485 ↗
19. Thrombectomy in acute ischemic stroke: challenges to procedural success10.5853/jos.2017.00752 ↗
20. Risk of thrombus fragmentation during endovascular stroke treatment10.3174/ajnr.A5105 ↗
21. The penumbra pivotal stroke trial: Safety and effectiveness of a new generation of mechanical devices for clot removal in intracranial large vessel occlusive disease10.1161/STROKEAHA.108.544957 ↗
22. A dedicated animal model for mechanical thrombectomy in acute stroke
23. Mechanical thrombectomy for acute ischemic stroke: thrombus-device interaction, efficiency, and complications in vivo10.1161/01.STR.0000248457.55493.85 ↗
24. G. Ye, R. Cao, J. Lu, P. Qi, J. Chen, D. Wang, CT-based higher thrombus density is associated with secondary embolism during mechanical thrombectomy: a preliminary observation, (2019). https://doi.org/10.1016/j.jstrokecerebrovasdis.2019.104311.10.1016/j.jstrokecerebrovasdis.2019.104311 ↗
25. Ischemic stroke: histological thrombus composition and pre-interventional CT attenuation are associated with intervention time and rate of secondary embolism10.1159/000481578 ↗
26. Per-pass analysis of thrombus composition in patients with acute ischemic stroke undergoing mechanical thrombectomy10.1161/STROKEAHA.118.023419 ↗
27. Investigating the mechanical behaviour of clot analogues through experimental and computational analysis
28. A new compressible hyperelastic model for the multi-axial deformation of blood clots occlusion in vessels10.1007/s10237-021-01446-4 ↗
29. The mechanical characterisation of bovine embolus analogues under various loading conditions10.1007/s13239-018-0352-3 ↗
30. Compressive mechanical properties of the intraluminal thrombus in abdominal aortic aneurysms and fibrin-based thrombus mimics10.1016/j.jbiomech.2008.10.024 ↗
31. Failure properties of intraluminal thrombus in abdominal aortic aneurysm under static and pulsating mechanical loads10.1016/j.jvs.2008.01.036 ↗
32. Tensile destruction test as an estimation of partial proteolysis in fibrin clots10.1002/ajh.10199 ↗
33. A planar biaxial constitutive relation for the luminal layer of intra-luminal thrombus in abdominal aortic aneurysms10.1016/j.jbiomech.2006.05.011 ↗
34. Biomechanics of abdominal aortic aneurysm in the! presence of endoluminal thrombus: Experimental characterisation and structural static computational analysis10.1016/S1078-5884(98)80031-2 ↗
35. CT and MRI early vessel signs reflect clot composition in acute stroke10.1161/STROKEAHA.110.605576 ↗
36. Analysis of thrombi retrieved from cerebral arteries of patients with acute ischemic stroke10.1161/01.STR.0000230307.03438.94 ↗
37. Histologic analysis of retrieved clots in acute ischemic stroke: correlation with stroke etiology and gradient-echo MRI10.3174/ajnr.A4402 ↗
38. Histopathologic composition of cerebral thrombi of acute stroke patients is correlated with stroke subtype and thrombus attenuation10.1371/journal.pone.0088882 ↗
39. Thrombus composition in acute ischemic stroke: a histopathological study of thrombus extracted by endovascular retrieval10.1016/j.neurad.2014.01.124 ↗
40. S. Duffy, M. Farrell, K. Mcardle, J. Thornton, D. Vale, E. Rainsford, L. Morris, D.S. Liebeskind, E. Maccarthy, M. Gilvarry, Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke, (n.d.). https://doi.org/10.1136/neurintsurg-2016-012308.10.1136/neurintsurg-2016-012308 ↗
41. Mechanical characterization of thromboemboli in acute ischemic stroke and laboratory embolus analogs10.3174/ajnr.A2485 ↗
42. Development of an in vitro model of calcified cerebral emboli in acute ischemic stroke for mechanical thrombectomy evaluation
43. Novel methodology to replicate clot analogs with diverse composition in acute ischemic stroke10.1136/neurintsurg-2016-012308 ↗
44. Thrombus composition and efficacy of thrombolysis and thrombectomy in acute ischemic stroke10.1161/STROKEAHA.120.032810 ↗
45. Per-pass analysis of thrombus composition in patients with acute ischemic stroke undergoing mechanical thrombectomy10.1161/STROKEAHA.118.023419 ↗
46. CT and MRI early vessel signs reflect clot composition in acute stroke10.1161/STROKEAHA.110.605576 ↗
47. O-027 Pathological analysis of extracted clots in embolectomy patients with acute ischaemic stroke
48. The impact of histological clot composition in embolic stroke10.1007/s00062-014-0347-x ↗
49. Investigation of fracture resistance of natural rubber/clay nanocomposites by J-testing10.1016/j.engfracmech.2010.04.021 ↗
50. (ASTM D 5054) - standard test methods for plane-strain fracture toughness and strain energy release rate of plastic materials
51. Measuring fracture toughness in biological materials10.1016/j.jmbbm.2017.07.007 ↗
52. Review of fracture toughness (G, K, J, CTOD, CTOA) testing and standardization10.1016/j.engfracmech.2012.02.001 ↗
53. The fracture toughness of soft tissues10.1016/j.jmbbm.2011.09.018 ↗
54. Mechanical properties of blood clots - a new test method10.1002/mawe.201000703 ↗
55. A new anisotropic soft tissue model for elimination of unphysical auxetic behaviour10.1016/j.jbiomech.2020.110006 ↗
56. Novel hyperelastic models for large volumetric deformations10.1016/j.ijsolstr.2020.01.019 ↗
57. A path independent integral and the approximate analysis of strain concentration by notches and cracks10.1115/1.3601206 ↗
58. Development of a test method to investigate mode II fracture and dissection of arteries10.1016/j.actbio.2020.11.023 ↗
59. B. FitzGibbon, B. Fereidoonnezhad, J. Concannon, N. Hynes, S. Sultan, K.M. Moerman, P. McGarry, A numerical investigation of the initiation of aortic dissection, (2021). https://doi.org/10.31224/OSF.IO/G4Z72.10.31224/osf.io/g4z72 ↗
60. Thrombus histology suggests cardioembolic cause in cryptogenic stroke10.1161/STROKEAHA.116.013105 ↗
61. Stroke etiology and thrombus computed tomography characteristics in patients with acute ischemic stroke: A MR CLEAN registry substudy10.1161/STROKEAHA.119.027749 ↗
62. Ischemic stroke: what does the histological composition tell us about the origin of the thrombus?10.1161/STROKEAHA.117.016590 ↗
63. Per-pass analysis of acute ischemic stroke clots: Impact of stroke etiology on extracted clot area and histological composition
64. Fibrinogen and fibrin in hemostasis and thrombosis10.1161/ATVBAHA.117.308564 ↗
65. High dose factor VIIa improves clot structure and stability in a model of haemophilia B10.1111/j.1365-2141.2005.05820.x ↗
66. Structural origins of fibrin clot rheology10.1016/S0006-3495(99)77113-4 ↗
67. Kane · 1988 · 71
68. Cellular procoagulant activity dictates clot structure and stability as a function of distance from the cell surface10.1161/ATVBAHA.108.176008 ↗
69. Transport physics and biorheology in the setting of hemostasis and thrombosis10.1111/jth.13280 ↗
70. The effect of red blood cells on thrombin generation10.1111/j.1365-2141.2006.06047.x ↗
71. Prothrombin activation in blood coagulation: the erythrocyte contribution to thrombin generation10.1182/blood-2012-05-427856 ↗
72. Fibrinogen and red blood cells in venous thrombosis10.1016/j.thromres.2014.03.017 ↗
73. Red blood cells: the forgotten player in hemostasis and thrombosis10.1111/jth.14360 ↗
74. Interplay of platelet contractility and elasticity of fibrin/erythrocytes in blood clot retraction10.1016/j.bpj.2017.01.005 ↗
75. Applicability assessment of a stent-retriever thrombectomy finite-element model10.1098/rsfs.2019.0123 ↗
76. Elasticity and fracture strain of whole blood clots
77. Fibrin mechanical properties and their structural origins10.1016/j.matbio.2016.08.003 ↗
78. Tear resistance of soft collagenous tissues
79. Measuring the effect of thrombosis, thrombus maturation and thrombolysis on clot mechanical properties in an in-vitro model10.1016/j.jbiomech.2021.110731 ↗