Cytocompatibility and early inflammatory response of human endothelial cells in direct culture with Mg-Zn-Sr alloys
Source abstract
Abstract
Crystalline Mg-Zinc (Zn)-Strontium (Sr) ternary alloys consist of elements naturally present in the human body and provide attractive mechanical and biodegradable properties for a variety of biomedical applications. The first objective of this study was to investigate the degradation and cytocompatibility of four Mg-4Zn-xSr alloys (x=0.15, 0.5, 1.0, 1.5wt%; designated as ZSr41A, B, C, and D respectively) in the direct culture with human umbilical vein endothelial cells (HUVEC) in vitro. The second objective was to investigate, for the first time, the early-stage inflammatory response in cultured HUVECs as indicated by the induction of vascular cellular adhesion molecule-1 (VCAM-1). The results showed that the 24-h in vitro degradation of the ZSr41 alloys containing a β-phase with a Zn/Sr at% ratio ∼1.5 was significantly faster than the ZSr41 alloys with Zn/Sr at% ∼1. Additionally, the adhesion density of HUVECs in the direct culture but not in direct contact with the ZSr41 alloys for up to 24h was not adversely affected by the degradation of the alloys. Importantly, neither culture media supplemented with up to 27.6mM Mg2+ ions nor media intentionally adjusted up to alkaline pH 9 induced any detectable adverse effects on HUVEC responses. In contrast, the significantly higher, yet non-cytotoxic, Zn2+ ion concentration from the degradation of ZSr41D alloy was likely the cause for the initially higher VCAM-1 expression on cultured HUVECs. Lastly, analysis of the HUVEC-ZSr41 interface showed near-complete absence of cell adhesion directly on the sample surface, most likely caused by either a high local alkalinity, change in surface topography, and/or surface composition. The direct culture method used in this study was proposed as a valuable tool for studying the design aspects of Zn-containing Mg-based biomaterials in vitro, in order to engineer solutions to address current shortcomings of Mg alloys for vascular device applications. Statement of significance Magnesium (Mg) alloys specifically designed for biodegradable implant applications have been the focus of biomedical research since the early 2000s. Physicochemical properties of Mg alloys make these metallic biomaterials excellent candidates for temporary biodegradable implants in orthopedic and cardiovascular applications. As Mg alloys continue to be investigated for biomedical applications, it is necessary to understand whether Mg-based materials or the alloying elements have the intrinsic ability to direct an immune response to improve implant integration while avoiding cell-biomaterial interactions leading to chronic inflammation and/or foreign body reactions. The present study utilized the direct culture method to investigate for the first time the in vitro transient inflammatory activation of endothelial cells induced by the degradation products of Zn-containing Mg alloys.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Magnesium Alloys: Properties and Applications · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
2. Degradable biomaterials based on magnesium corrosion10.1016/j.cossms.2009.04.001 ↗
3. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
4. Developments in metallic biodegradable stents10.1016/j.actbio.2009.10.006 ↗
5. Short-term and long-term effects of orthopedic biodegradable implants10.1615/JLongTermEffMedImplants.v21.i2.10 ↗
6. Current research in the pathogenesis of aseptic implant loosening associated with particulate wear debris
7. Tissue response and biomaterial integration: the efficacy of in vitro methods10.1016/S1389-0344(02)00019-9 ↗
8. Immune responses to implants – a review of the implications for the design of immunomodulatory biomaterials10.1016/j.biomaterials.2011.05.078 ↗
9. Infection of orthopedic implants and the use of antibiotic-loaded bone cements: a review10.1080/000164701317268978 ↗
10. Chapter 4 Mechanisms of inflammation and infection with implanted devices10.1016/1054-8807(93)90045-4 ↗
11. Foreign body reaction to biomaterials10.1016/j.smim.2007.11.004 ↗
12. Evolving functions of endothelial cells in inflammation10.1038/nri2171 ↗
13. Vascular cell adhesion molecule-1 expression and signaling during disease: regulation by reactive oxygen species and antioxidants10.1089/ars.2010.3522 ↗
14. Chapter 12 Immunological response of electrostatic charge at the surface of biomaterials
15. Increased expression of ICAM-1, E-selectin, and VCAM-1 by cultured human endothelial cells upon exposure to haptens10.1111/j.1600-0625.1992.tb00188.x ↗
16. Goebeler · J. Invest. Dermatol. · 1993 · 100 · 75910.1111/1523-1747.ep12476328 ↗
17. The role of metal corrosion in inflammatory processes: induction of adhesion molecules by heavy metal ions10.1007/BF00213138 ↗
18. Activation of nuclear factor-kappa B and gene expression in human endothelial cells by the common haptens nickel and cobalt10.4049/jimmunol.155.5.2459 ↗
19. Heavy metal ion induction of adhesion molecules and cytokines in human endothelial cells: the role of NF-κB, lκB-α and AP-110.1159/000164135 ↗
20. Mechanisms of cell activation by heavy metal ions10.1002/(SICI)1097-4636(19981205)42:3<443::AID-JBM14>3.0.CO;2-H ↗
21. Effect of vascular stent alloys on expression of cellular adhesion molecules by endothelial cells10.1615/JLongTermEffMedImplants.v15.i1.50 ↗
22. In vitro interaction between surface-treated Ti-6Al-4V titanium alloy and human peripheral blood mononuclear cells10.1002/jbm.a.30366 ↗
23. Analysis of the effects of surface treatments on nickel release from nitinol wires and their impact on candidate gene expression in endothelial cells10.1007/s10856-006-0087-9 ↗
24. A major role for VCAM-1, but not ICAM-1, in early atherosclerosis10.1172/JCI11871 ↗
25. An important role for VCAM-1, but not for ICAM-1 in restenosis following coronary implantation10.5152/akd.2010.137 ↗
26. Development and evaluation of a magnesium-zinc-strontium alloy for biomedical applications – alloy processing10.1016/j.msec.2013.04.054 ↗
27. In vitro degradation of four magnesium–zinc–strontium alloys and their cytocompatibility with human embryonic stem cells10.1007/s10856-013-4853-1 ↗
28. In vitro interactions of blood, platelet, and fibroblast with biodegradable Magnesium-Zinc-Strontium alloys10.1002/jbm.a.35429 ↗
29. Investigation of magnesium–zinc–calcium alloys and bone marrow derived mesenchymal stem cell response in direct culture10.1016/j.actbio.2014.10.018 ↗
30. Reprint of: Improved cytotoxicity testing of magnesium materials10.1016/j.mseb.2011.06.002 ↗
31. Recommendation for modifying current cytotoxicity testing standards for biodegradable magnesium-based materials10.1016/j.actbio.2015.04.011 ↗
32. Optimized in vitro procedure for assessing the cytocompatibility of magnesium-based biomaterials10.1016/j.actbio.2015.06.005 ↗
33. Biodegradable magnesium scaffolds: Part 1: appropriate inflammatory response10.1002/jbm.a.31170 ↗
34. Corrosion of magnesium alloy AZ31 screws is dependent on the implantation site10.1016/j.mseb.2011.02.010 ↗
35. Comparison of morphological changes in efferent lymph nodes after implantation of resorbable and non-resorbable implants in rabbits
36. Magnesium alloys for temporary implants in osteosynthesis: in vivo studies of their degradation and interaction with bone10.1016/j.actbio.2011.11.008 ↗
37. The formation of an organic coat and the release of corrosion microparticles from metallic magnesium implants10.1016/j.actbio.2013.03.012 ↗
38. Magnesium corrosion particles do not interfere with the immune function of primary human and murine macrophages
39. Effects of degradable Mg-Ca alloys on dendritic cell function10.1177/0885328209360424 ↗
40. In vivo corrosion of four magnesium alloys and the associated bone response10.1016/j.biomaterials.2004.09.049 ↗
41. Influence of artificial biological fluid composition on the biocorrosion of potential orthopedic Mg-Ca, AZ31, AZ91 alloys10.1088/1748-6041/4/6/065011 ↗
42. Biocorrosion properties of as-extruded Mg–Nd–Zn–Zr alloy compared with commercial AZ31 and WE43 alloys10.1016/j.matlet.2011.08.079 ↗
43. Coronary stents: a materials perspective10.1016/j.biomaterials.2006.11.042 ↗
44. Biodegradable metals for cardiovascular stent application: interests and new opportunities10.3390/ijms12074250 ↗
45. The effects of nanostructured hydroxyapatite coating on the biodegradation and cytocompatibility of magnesium implants10.1002/jbm.a.34530 ↗
46. Mitotic progression becomes irreversible in prometaphase and collapses when Wee1 and Cdc25 are inhibited10.1091/mbc.e10-07-0599 ↗
47. An in vitro mechanism study on the proliferation and pluripotency of human embryonic stems cells in response to magnesium degradation10.1371/journal.pone.0076547 ↗
48. Assessing the corrosion of biodegradable magnesium implants: a critical review of current methodologies and their limitations10.1016/j.actbio.2011.11.014 ↗
49. Kelly · 2002
50. Nanometer analysis of cell spreading on matrix-coated surfaces reveals two distinct cell states and STEPs10.1016/S0006-3495(04)74246-0 ↗
51. Optimized medium for clonal growth of human microvascular endothelial cells with minimal serum10.1007/BF02628418 ↗
52. Investigation of the mechanical and degradation properties of Mg–Sr and Mg–Zn–Sr alloys for use as potential biodegradable implant materials10.1016/j.jmbbm.2011.07.018 ↗
53. Microstructures, mechanical and cytocompatibility of degradable Mg–Zn based orthopedic biomaterials10.1016/j.matdes.2014.01.031 ↗
54. Thermodynamic assessment of the Mg–Zn–Sr system10.1016/j.intermet.2006.03.011 ↗
55. The microstructure and the degradation behaviour of a novel biomaterial Mg-Zn-Sr alloy sheet in simulated body fluid (SBF)10.1166/asl.2013.4442 ↗
56. Influence of composition and processing on the corrosion of magnesium alloys containing binary and ternary additions of zinc and strontium10.5006/1417 ↗
57. Recent metallic materials for biomedical applications10.1007/s11661-002-0109-2 ↗
58. Corrosion behaviour of AZ31 magnesium alloy with different grain sizes in simulated biological fluids10.1016/j.actbio.2009.04.041 ↗
59. The degradation performance of AZ31 bioabsorbable magnesium alloy stent implanted in the abdominal aorta of rabbits
60. Research on Mg-Zn-Ca alloy as degradable biomaterial
61. Biodegradability engineering of biodegradable Mg alloys: tailoring the electrochemical properties and microstructure of constituent phases10.1038/srep02367 ↗
62. On the in vitro and in vivo degradation performance and biological response of new biodegradable Mg–Y–Zn alloys10.1016/j.actbio.2009.10.008 ↗
63. In vitro degradation behavior and cytocompatibility of Mg–Zn–Zr alloys10.1007/s10856-010-4111-8 ↗
64. Microstructure, mechanical and corrosion properties and biocompatibility of Mg–Zn–Mn alloys for biomedical application10.1016/j.msec.2008.08.024 ↗
65. Bio-corrosion characterization of Mg–Zn–X (X=Ca, Mn, Si) alloys for biomedical applications10.1007/s10856-009-3956-1 ↗
66. In vitro degradation behavior of ternary Mg-Zn-Se and Mg-Zn-Cu alloys as biomaterials
67. The in vitro biological properties of Mg-Zn-Sr alloy and superiority for preparation of biodegradable intestinal anastomosis rings10.12659/MSM.890638 ↗
68. The effects of surface and biomolecules on magnesium degradation and mesenchymal stem cell adhesion10.1002/jbm.a.33188 ↗
69. In vitro evaluation of the surface effects on magnesium-yttrium alloy degradation and mesenchymal stem cell adhesion10.1002/jbm.a.33290 ↗
70. The physiology of urinary concentration: an update10.1016/j.semnephrol.2009.03.008 ↗
71. Endothelial responses of magnesium and other alloying elements in magnesium-based stent materials10.1039/C4MT00244J ↗
72. Ph drift of “physiological buffers” and culture media used for cell incubation during in vitro studies10.1016/S1056-8719(98)00019-7 ↗
73. Regulation of magnesium homeostasis and transport in mammalian cells10.1016/j.abb.2006.07.012 ↗
74. High concentrations of magnesium modulate vascular endothelial cell behaviour in vitro10.1016/j.bbadis.2004.02.004 ↗
75. Low magnesium promotes endothelial cell dysfunction: implications for atherosclerosis, inflammation and thrombosis10.1016/j.bbadis.2004.01.002 ↗
76. Effects of magnesium alloys extracts on adult human bone marrow-derived stromal cell viability and osteogenic differentiation10.1088/1748-6041/5/4/045005 ↗
77. Lorenzo de Mele, biological effects of magnesium particles degradation on UMR-106 cell line: influence of fluoride treatments10.1016/j.colsurfb.2011.07.035 ↗
78. Two distinct monokines, interleukin 1 and tumor necrosis factor, each independently induce biosynthesis and transient expression of the same antigen on the surface of cultured human vascular endothelial cells10.4049/jimmunol.136.5.1680 ↗
79. Overlapping patterns of activation of human endothelial cells by interleukin 1, tumor necrosis factor, and immune interferon10.4049/jimmunol.137.6.1893 ↗
80. E-selectin and intercellular adhesion molecule-1 are released by activated human endothelial cells in vitro
81. Direct expression cloning of vascular cell adhesion molecule 1, a cytokine-induced endothelial protein that binds to lymphocytes10.1016/0092-8674(89)90775-7 ↗
82. Intracellular metal ion chelators inhibit TNFα-induced SP-1 activation and adhesion molecule expression in human aortic endothelial cells10.1016/S0891-5849(02)01375-8 ↗
83. Magnesium sulfate suppresses inflammatory responses by human umbilical vein endothelial cells (HuVECs) through the NFκB pathway10.1016/j.jri.2006.06.004 ↗
84. The effect of metallic magnesium degradation products on osteoclast-induced osteolysis and attenuation of NF-κB and NFATc1 signaling10.1016/j.biomaterials.2014.04.044 ↗
85. Zinc activates NF-κB in HUT-78 cells10.1067/mlc.2001.118108 ↗
86. Zinc up-regulates NF-κB activation via phosphorylation of IκB in HUT-78 (Th0) cells10.1016/j.febslet.2007.08.030 ↗
87. A comparative study of several transition metals in Fenton-like reaction systems at circum-neutral pH
88. Wilham · 2007 · 190
89. Zinc regulates iNOS-derived nitric oxide formation in endothelial cells10.1016/j.redox.2014.06.011 ↗
90. Superoxide dismutase activity and zinc and copper concentrations in growth retardation10.1385/BTER:102:1-3:051 ↗
91. Nitric oxide regulates vascular cell adhesion molecule 1 gene expression and redox-sensitive transcriptional events in human vascular endothelial cells10.1073/pnas.93.17.9114 ↗
92. Superoxide dismutase inhibits the expression of vascular cell adhesion molecule-1 and intracellular cell adhesion molecule-1 induced by tumor necrosis factor-α in human endothelial cells through the JNK/p38 pathways10.1161/01.ATV.0000152114.00114.d8 ↗
93. Clinical, immunological, anti-inflammatory and antioxidant roles of zinc10.1016/j.exger.2007.10.013 ↗
94. Zinc: role in immunity, oxidative stress and chronic inflammation
95. Zinc: an antioxidant and anti-inflammatory agent: role of zinc in degenerative disorders of aging10.1016/j.jtemb.2014.07.019 ↗
96. In vivo corrosion behavior of Mg-Mn-Zn alloy for bone implant application10.1002/jbm.a.31273 ↗
97. In vivo evaluation of biodegradable magnesium alloy bone implant in the first 6 months implantation10.1002/jbm.a.32132 ↗
98. In vitro and in vivo evaluation of the surface bioactivity of a calcium phosphate coated magnesium alloy10.1016/j.biomaterials.2008.12.001 ↗
99. Increased adhesion and activation of polymorphonuclear neutrophil granulocytes to endothelial cells under heavy metal exposure in vitro10.1159/000163883 ↗
100. Nickel hydroxy carbonate increases tumour necrosis factor alpha and interleukin 6 secretion by alveolar macrophages10.1002/jat.2550140510 ↗