journal article·2018-04

Biological connective tissues exhibit viscoelastic and poroelastic behavior at different frequency regimes: Application to tendon and skin biophysics

Ramin Oftadeh, Brianne K. Connizzo, Hadi Tavakoli Nia, Christine Ortiz, Alan J. Grodzinsky

Acta Biomaterialia· Volume 70
Publisher page

Abstract

In this study, a poroviscoelastic finite element model (FEM) was developed and used in conjunction with an AFM-based wide-bandwidth nanorheology system to predict the frequency-dependent mechanical behavior of tendon and dermis subjected to compression via nanoindentation. The aim was to distinguish between loading rates that are dominated by either poroelasticity, viscoelasticity, or the superposition of these processes. Using spherical probe tips having different radii, the force and tip displacement were measured and the magnitude, E∗, and phase angle, ϕ, of the dynamic complex modulus were evaluated for mouse supraspinatus tendon and mouse dermis. The peak frequencies of the phase angle were associated with the characteristic time constants of poroelastic and viscoelastic material behavior. The developed FE model could predict the separate poroelastic and viscoelastic responses of these soft tissues over a 4 decade frequency range, showing good agreement with experimental results. We observed that poroelasticity was the dominant energy dissipation mechanism for mouse dermis and supraspinatus tendon at higher indentation frequencies (102 to 104 Hz) whereas viscoelasticity was typically dominant at lower frequencies (<102 Hz). These findings show the underlying mechanical behavior of biological connective tissues and give insight into the role played by these different energy dissipation mechanisms in governing the function of these tissues at nanoscale. Statement of significance Soft biological tissues exhibit complex, load- and time-dependent mechanical behavior. Evaluating their mechanical behavior requires sophisticated experimental tools and numerical models that can capture the fundamental mechanisms governing tissue function. Using an Atomic-force-microscopy-based rheology system and finite element models, the roles of the two most dominant time-dependent mechanisms (poroelasticity and viscoelasticity) that govern the dynamic loading behavior of mouse skin and tendon have been investigated. FE models were able to predict and quantify the contribution of each mechanism to the overall dynamic response and confirming the presence of these two distinct mechanisms in the mechanical response. Overall, these results provide novel insight into the viscoelastic and poroelastic properties of mouse skin and tendon and promote better understanding of the underlying origins of each mechanism.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Tendon Structure and Treatment · Cellular Mechanics and Interactions · Force Microscopy Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (65)

Show source-provided references
1. Grodzinsky · 2011
2. Fluid transport and mechanical properties of articular cartilage: a review10.1016/0021-9290(84)90031-9 ↗
3. Oscillatory compressional behavior of articular cartilage and its associated electromechanical properties10.1115/1.3138294 ↗
4. Tribology of skin: review and analysis of experimental results for the friction coefficient of human skin10.1007/s11249-011-9854-y ↗
5. Structure and function of the epidermal barrier10.1016/j.ajic.2006.05.295 ↗
6. Structure-function relationships in tendons: a review10.1111/j.1469-7580.2008.00864.x ↗
7. Function and biomechanics of tendons10.1111/j.1600-0838.1997.tb00120.x ↗
8. Poroelasticity of cartilage at the nanoscale10.1016/j.bpj.2011.09.011 ↗
9. High-bandwidth AFM-based rheology reveals that cartilage is most sensitive to high loading rates at early stages of impairment10.1016/j.bpj.2013.02.048 ↗
10. Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology10.1016/j.jbiomech.2017.01.029 ↗
11. Equivalent stiffness after glycosaminoglycan depletion in tendon—an ultra-structural finite element model and corresponding experiments10.1016/j.jtbi.2010.10.007 ↗
12. Curved beam computed tomography based structural rigidity analysis of bones with simulated lytic defect: a comparative study with finite element analysis10.1038/srep32397 ↗
13. Hierarchical analysis and multi-scale modelling of rat cortical and trabecular bone10.1098/rsif.2015.0070 ↗
14. The hyperelastic and failure behaviors of skin in relation to the dynamic application of microscopic penetrators in a murine model10.1016/j.actbio.2016.10.021 ↗
15. Simulating plastic surgery: from human skin tensile tests, through hyperelastic finite element models to real-time haptics10.1016/j.pbiomolbio.2010.09.013 ↗
16. An anisotropic, hyperelastic model for skin: experimental measurements, finite element modelling and identification of parameters for human and murine skin10.1016/j.jmbbm.2012.10.021 ↗
17. Compressive viscoelasticity of freshly excised mouse skin is dependent on specimen thickness, strain level and rate10.1371/journal.pone.0120897 ↗
18. Elastic modulus and viscoelastic properties of full thickness skin characterised at micro scales10.1016/j.biomaterials.2012.11.035 ↗
19. Effect of age and exercise on the viscoelastic properties of rat tail tendon10.1007/s10439-013-0796-4 ↗
20. A poroelastic model that predicts some phenomenological responses of ligaments and tendons10.1115/1.2798285 ↗
21. A fibril-network-reinforced biphasic IVIodel of cartilage in unconfined compression10.1115/1.2798330 ↗
22. Biphasic finite element modeling reconciles mechanical properties of tissue-engineered cartilage constructs across testing platforms10.1089/ten.tea.2016.0191 ↗
23. Unconfined compression of hydrated viscoelastic tissues: a biphasic poroviscoelastic analysis
24. A fibril-reinforced poroviscoelastic swelling model for articular cartilage10.1016/j.jbiomech.2004.07.003 ↗
25. A fibre-reinforced poroviscoelastic model accurately describes the biomechanical behaviour of the rat achilles tendon10.1371/journal.pone.0126869 ↗
26. Poroviscoelastic finite element model including continuous fiber distribution for the simulation of nanoindentation tests on articular cartilage10.1016/j.jmbbm.2013.12.003 ↗
27. High-bandwidth AFM-based rheology is a sensitive indicator of early cartilage aggrecan degradation relevant to mouse models of osteoarthritis10.1016/j.jbiomech.2014.11.012 ↗
28. Time-dependent nanomechanics of cartilage10.1016/j.bpj.2011.02.031 ↗
29. Nonlinear analysis of cartilage in unconfined ramp compression using a fibril reinforced poroelastic model10.1016/S0268-0033(99)00013-3 ↗
30. Tensile properties and fiber alignment of human supraspinatus tendon in the transverse direction demonstrate inhomogeneity, nonlinearity, and regional isotropy10.1016/j.jbiomech.2009.10.017 ↗
31. Effects of stress shielding on the transverse mechanical properties of rabbit patellar tendons10.1115/1.1319660 ↗
32. Effect of fiber orientation and strain rate on the nonlinear uniaxial tensile material properties of tendon10.1115/1.1614819 ↗
33. Stresses in the local collagen network of articular cartilage: a poroviscoelastic fibril-reinforced finite element study10.1016/S0021-9290(03)00267-7 ↗
34. In situ multi-level analysis of viscoelastic deformation mechanisms in tendon collagen10.1016/j.jsb.2009.10.002 ↗
35. Investigating load relaxation mechanics in tendon10.1016/j.jmbbm.2007.03.002 ↗
36. Viscoelastic behavior of human connective tissues: relative contribution of viscous and elastic components10.3109/03008208309005612 ↗
37. Viscoelastic properties of self-assembled type I collagen fibers: molecular basis of elastic and viscous behaviors10.1080/03008200290001302 ↗
38. Role of copper in collagen cross-linking and its influence on selected mechanical properties of chick bone and tendon10.1093/jn/112.4.708 ↗
39. Marques · 2012
40. The apparent viscoelastic behavior of articular cartilage—the contributions from the intrinsic matrix viscoelasticity and interstitial fluid flows10.1115/1.3138591 ↗
41. Anisotropic strain-dependent material properties of bovine articular cartilage in the transitional range from tension to compression10.1016/j.jbiomech.2003.12.008 ↗
42. Collagen V-heterozygous and-null supraspinatus tendons exhibit altered dynamic mechanical behaviour at multiple hierarchical scales10.1098/rsfs.2015.0043 ↗
43. Impaired biomechanical properties of diabetic skin: implications in pathogenesis of diabetic wound complications10.1016/j.ajpath.2011.01.015 ↗
44. Flurkey · 2007 · 637
45. Aggrecan nanoscale solid–fluid interactions are a primary determinant of cartilage dynamic mechanical properties10.1021/nn5062707 ↗
46. Calibration of atomic-force microscope tips10.1063/1.1143970 ↗
47. Biphasic indentation of articular cartilage—I. heoretical analysis10.1016/0021-9290(87)90036-4 ↗
48. The influence of coracoacromial arch anatomy on rotator cuff tears10.1016/S1058-2746(09)80010-4 ↗
49. The influence of variations of the coracoacromial arch on the development of rotator cuff tears10.1007/BF00440591 ↗
50. Differences in collagen architecture between keloid, hypertrophic scar, normotrophic scar, and normal skin: an objective histopathological analysis10.1111/j.1524-475X.2009.00533.x ↗
51. Static and dynamic nanomechanical properties of human skin tissue using atomic force microscopy: effect of scarring in the upper dermis10.1016/j.actbio.2012.06.042 ↗
52. Comparison of structural anisotropic soft tissue models for simulating Achilles tendon tensile behaviour10.1016/j.jmbbm.2016.04.007 ↗
53. The viscoelastic, hyperelastic and scale dependent behaviour of freshly excised individual skin layers10.1016/j.biomaterials.2011.03.012 ↗
54. Relationship between phase shift and energy dissipation in tapping-mode scanning force microscopy10.1063/1.122632 ↗
55. Micromechanical poroelastic finite element and shear-lag models of tendon predict large strain dependent Poisson’s ratios and fluid expulsion under tensile loading10.1016/j.actbio.2015.04.035 ↗
56. A fiber matrix model for interstitial fluid flow and permeability in ligaments and tendons
57. Micromechanical models of helical superstructures in ligament and tendon fibers predict large Poisson's ratios10.1016/j.jbiomech.2010.01.004 ↗
58. A finite element model predicts the mechanotransduction response of tendon cells to cyclic tensile loading10.1007/s10237-007-0104-z ↗
59. A mixture approach to the mechanics of skin10.1016/0021-9290(87)90147-3 ↗
60. In vitro compression of a soft tissue layer on a rigid foundation10.1016/0021-9290(87)90321-6 ↗
61. Material characterization of human medial collateral ligament10.1115/1.2834890 ↗
62. Multiscale strain analysis of tendon subjected to shear and compression demonstrates strain attenuation, fiber sliding, and reorganization10.1002/jor.22955 ↗
63. Different regions of bovine deep digital flexor tendon exhibit distinct elastic, but not viscous, mechanical properties under both compression and shear loading10.1016/j.jbiomech.2014.07.026 ↗
64. Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons10.1016/j.actbio.2016.06.012 ↗
65. The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons10.1016/j.jmbbm.2015.04.009 ↗