Bone response to a novel Ti–Ta–Nb–Zr alloy
Source abstract
Abstract
Commercially pure titanium (cp-Ti) is regarded as the state-of-the-art material for bone-anchored dental devices, whereas the mechanically stronger alloy (Ti-6Al-4V), made of titanium, aluminum (Al) and vanadium (V), is regarded as the material of choice for high-load applications. There is a call for the development of new alloys, not only to eliminate the potential toxic effect of Al and V but also to meet the challenges imposed on dental and maxillofacial reconstructive devices, for example. The present work evaluates a novel, dual-stage, acid-etched, Ti-Ta-Nb-Zr alloy implant, consisting of elements that create low toxicity, with the potential to promote osseointegration in vivo. The alloy implants (denoted Ti-Ta-Nb-Zr) were evaluated after 7 days and 28 days in a rat tibia model, with reference to commercially pure titanium grade 4 (denoted Ti). Analyses were performed with respect to removal torque, histomorphometry and gene expression. The Ti-Ta-Nb-Zr showed a significant increase in implant stability over time in contrast to the Ti. Further, the histological and gene expression analyses suggested faster healing around the Ti-Ta-Nb-Zr, as judged by the enhanced remodeling, and mineralization, of the early-formed woven bone and the multiple positive correlations between genes denoting inflammation, bone formation and remodeling. Based on the present experiments, it is concluded that the Ti-Ta-Nb-Zr alloy becomes osseointegrated to at least a similar degree to that of pure titanium implants. This alloy is therefore emerging as a novel implant material for clinical evaluation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (54)
Show source-provided references
1. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period
2. Osseointegration in maxillofacial prosthetics. 1. Intraoral applications10.1016/0022-3913(86)90184-8 ↗
3. Osseointegration in maxillofacial prosthetics. 2. Extraoral applications10.1016/0022-3913(86)90040-5 ↗
4. Biomedical applications of titanium and its alloys10.1007/s11837-008-0031-1 ↗
5. Titanium alloy mini-implants for orthodontic anchorage: immediate loading and metal ion release10.1016/j.actbio.2006.10.010 ↗
6. The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study10.1111/j.1600-0501.2007.01395.x ↗
7. Morphological studies on machined implants of commercially pure titanium and titanium alloy (Ti6Al4V) in the rabbit10.1002/jbm.b.31404 ↗
8. The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt–chromium-alloy wear particles10.2106/00004623-199306000-00004 ↗
9. Reduced toxicity and superior cellular response of preosteoblasts to Ti–6Al–7Nb alloy and comparison with Ti–6Al–4V10.1002/jbm.a.34492 ↗
10. In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium10.1302/0301-620X.79B2.0790311 ↗
11. Inhibition of apatite formation by titanium and vanadium ions10.1002/jbm.820231305 ↗
12. Evaluations of bone tissue integration to pure and alloyed titanium implants10.1111/j.1708-8208.2007.00077.x ↗
13. Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants10.1034/j.1600-0501.1998.090101.x ↗
14. Ultrastructural differences of the interface zone between bone and Ti 6Al 4V or commercially pure titanium10.1016/0141-5425(89)90158-1 ↗
15. Interface between titanium 6,4 alloy implants and bone10.1016/S0901-5027(87)80087-5 ↗
16. Mechanical biocompatibilities of titanium alloys for biomedical applications10.1016/j.jmbbm.2007.07.001 ↗
17. Titanium alloys for biomedical applications10.1016/j.msec.2005.08.032 ↗
18. Biocompatibility of β-stabilizing elements of titanium alloys10.1016/j.biomaterials.2004.01.021 ↗
19. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium10.1016/S0142-9612(00)00275-1 ↗
20. Bone apposition to a titanium-zirconium alloy implant, as compared to two other titanium-containing implants10.22203/eCM.v023a21 ↗
21. A review of titanium zirconium (TiZr) alloys for use in endosseous dental implants10.3390/ma5081348 ↗
22. Thermocalc Software. https://www.thermocalc.se.
23. Ansara I, Dinsdale AT, Rand MH, editors. Thermochemical database for light metal alloys, vol. 2. July 1998, EUR18499, Final report: EU-COST507.
24. Thermodynamic analysis of the stable phases in the Zr–Nb system and calculation of the phase-diagram
25. Norgren S. Titanium-based alloy, US Patent US8492002 B2, 2013.
26. Hedlund A. The effect of heat treatments on titanium grade 23 and novel titanium alloys for medical applications [M.Sc. thesis]. Stockholm: Royal Institute of Technology, KTH; 2011.
27. Olsson N. Mechanical properties, phases and structures of titanium alloys [M.Sc. thesis]. Stockholm: Royal Institute of Technology, KTH; 2008.
28. Brunette · 2001
29. 3D SEM for surface topography quantification – a case study on dental surfaces10.1088/1742-6596/483/1/012026 ↗
30. Critical factors in SEM 3D stereo microscopy10.1088/0957-0233/19/6/065705 ↗
31. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat10.1016/S0142-9612(97)00018-5 ↗
32. An in-vivo method for biomechanical characterization of bone-anchored implants10.1016/S1350-4533(98)00023-X ↗
33. In vivo gene expression in response to anodically oxidized versus machined titanium implants10.1002/jbm.a.32475 ↗
34. Primer3 on the WWW for general users and for biologist programmers
35. A new mathematical model for relative quantification in real-time RT-PCR10.1093/nar/29.9.e45 ↗
36. Surface spectroscopic characterization of titanium implant materials10.1016/0368-2048(95)02530-8 ↗
37. A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: a prospective study of 51 patients10.1302/0301-620X.96B1.31905 ↗
38. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces10.1002/jbm.a.30518 ↗
39. Oxidized titanium implants enhance osseointegration via mechanisms involving RANK/RANKL/OPG regulation
40. Implant surface roughness and bone healing: a systematic review10.1177/154405910608500603 ↗
41. Biomechanical characterization of osseointegration during healing: an experimental in vivo study in the rat10.1016/S0142-9612(97)00018-5 ↗
42. The correlation between gene expression of proinflammatory markers and bone formation during osseointegration with titanium implants10.1016/j.biomaterials.2010.09.011 ↗
43. Bone response to laser-induced micro- and nano-size titanium surface features10.1016/j.nano.2010.10.006 ↗
44. A histomorphometric and removal torque study of screw-shaped titanium implants with three different surface topographies10.1034/j.1600-0501.1995.060103.x ↗
45. Molecular and structural patterns of bone regeneration in surgically created defects containing bone substitutes10.1016/j.biomaterials.2013.12.084 ↗
46. Global biomechanical model for dental implants10.1016/j.jbiomech.2011.02.002 ↗
47. A 1-year follow-up of implants of differing surface roughness placed in rabbit bone
48. Understanding mechanisms and factors related to implant fixation; a model study of removal torque10.1016/j.jmbbm.2014.02.006 ↗
49. A comparative study of zirconium and titanium implants in rat: osseointegration and bone material quality
50. The osseointegration behavior of titanium-zirconium implants in ovariectomized rabbits10.1111/clr.12141 ↗
51. Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium10.1023/A:1018579605426 ↗
52. In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy
53. Comparison of metal release from various metallic biomaterials in vitro10.1016/j.biomaterials.2004.02.005 ↗
54. Comparison of metal concentrations in rat tibia tissues with various metallic implants10.1016/j.biomaterials.2004.01.064 ↗