journal article·2015-02

Electrical behavior of ZnO-valinomycin coated Ag electrode for the detection of K+ in blood

Priyabrata Pattanaik, D. K. Mishra, Jyoshnarani Mohapatra, E. Subudhi, Debi Prasad Das, Sushanta Kumar Kamilla

Publisher page

Abstract

ZnO and ZnO-valinomycin coated over Ag substrates were prepared by chemical wet and dry technique. ZnO film was grown along (101) direction due to the implication of valinomycin with it. Fibre type of micrographs of ZnO-valinomycin having length 8–10 µm and average diameters of 0.5 µm have been observed under scanning electron microscope. A comparative electrical studies have been carried out in between ZnO coated Ag substrate and ZnO-valinomycin coated Ag substrate to identify the suitability of the electrode. ZnO-valinomycin coated film on Ag substrate shows a very good response for K+ sensing in comparison to the ZnO coated film on Ag substrate. The increased surface area of the ZnO due to the presence of valinomycin is the prime reason for the good sensing response. This is the reason why ZnO-valinomycin coated over Ag substrate is considered for the detection of K+ in animal blood. The electrical studies clearly establish that ZnO-valinomycin coated Ag substrate is suitable to detect a small percentage of K+ ions in the blood.
Source: openaire · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical sensors and biosensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. K.V. Kong, C.J.H. Ho, T. Gong, W.K.O. Lau, M. Olivo, Sensitive SERS glucose sensing in biological media using alkyne functionalized boronic acid on planar substrates. Biosens. Bioelectron 56, 186–191 (2014)10.1016/j.bios.2013.12.062 ↗
2. Z. Chen, J. Guo, S. Zhang, L. Chen, A one-step electrochemical sensor for rapid detection of potassium ion based on structure-switching aptamer. Sens. Actuators B 188, 1155–1157 (2013)10.1016/j.snb.2013.08.039 ↗
3. L. Fang, B. Liang, G. Yang, Y. Hu, Q. Zhu, X. Ye, Study of glucose biosensor lifetime improvement in 37 C serum based on PANI enzyme immobilization and PLGA biodegradable membrane. Biosens. Bioelectron 56, 91–96 (2014)10.1016/j.bios.2014.01.017 ↗
4. P.C. Pandey, R. Prakash, Polyindole modified potassium ion-sensor using dibenzo-18-crown-6 mediated PVC matrix membrane. Sens Actuators B 46, 61–65 (1998)10.1016/S0925-4005(97)00332-8 ↗
5. J. Yim, H. Kim, S. Ryu, S. Song, H.O. Kim, K.A. Hyun, H. Jung, C. Joo, Photothermal spectral-domain optical coherence reflectometry for direct measurement of hemoglobin concentration of erythrocytes. Biosens. Bioelectron 57, 59–64 (2014)10.1016/j.bios.2014.01.052 ↗
6. Q.Q. Ren, X.J. Yuan, X.R. Huang, W. Wen, Y.D. Zhao, W. Chen, In vivo monitoring of oxidative burst on aloe under salinity stress using hemoglobin and single-walled carbon nanotubes modified carbon fiber ultramicroelectrode. Biosens. Bioelectron 50, 318–324 (2013)10.1016/j.bios.2013.07.001 ↗
7. Z. Chen, L. Chen, H. Ma, T. Zhou, X. Li, Aptamer biosensor for label-free impedance spectroscopy detection of potassium ion based on DNA G-quadruplex conformation. Biosens. Bioelectron 48, 108–112 (2013)10.1016/j.bios.2013.04.007 ↗
8. P. Bühlmann, E. Pretsch, E. Bakker, Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 98, 1593–1688 (1998)10.1021/cr970113+ ↗
9. B.T.T. Nguyen, J.Q. Ang, C.S. Toh, Sensitive detection of potassium ion using Prussian blue nanotube sensor. Electrochem. Commun. 11, 1861–1864 (2009)10.1016/j.elecom.2009.08.003 ↗
10. J.Q. Ang, S.F.Y. Li, Novel sensor for simultaneous determination of K+ and Na+ using Prussian blue pencil graphite electrode. Sens Actuators B 173, 914–918 (2012)10.1016/j.snb.2012.07.119 ↗
11. S.M. Usman Ali, H.A. Muhammad, F. Alimujiang, N. Omer, W. Magnus, B. Cecilia, S. Peter, H.E. Ulrika, E. Fredrik, D. Bengt, Intracellular K determination with a potentiometric microelectrode based on ZnO nanowires. Nanotechnol. IEEE Trans. 10, 913–919 (2011)10.1109/TNANO.2010.2089696 ↗
12. P. Pattanaik, S.K. Kamilla, J. Mohapatra, B.K. Jena, D.P. Das, D.K. Mishra, Deposition of ZnO-Valinomycin Film on Al Substrate for the Detection of K+ in KOH Solution. Nanosci. Nanotechnol. Lett. 6, 216–220 (2014)10.1166/nnl.2014.1740 ↗
13. M. Cardona, K.L. Shaklee, F.H. Pollak, Electroreflectance at a Semiconductor-Electrolyte Interface. Phys. Rev. 154, 696–720 (1967)10.1103/PhysRev.154.696 ↗
14. J. Newman, K.E. Thomas-Alyea, Electrochemical systems, vol. 3 (Wiley, New York, 2004)
15. P. Pattanaik, S.K. Kamilla, D.P. Das, D.K. Mishra, Experimental and simulated study of electrical behaviour of ZnO film deposited on Al substrate for device applications. J. Mater. Sci. Mater. Electron. 25, 3062–3068 (2014)10.1007/s10854-014-1984-1 ↗
16. Z.H. Ibupoto, S.M.U.A. Shah, K. Khun, M. Willander, Electrochemical l-lactic acid sensor based on immobilized ZnO nanorods with lactate oxidase. Sensors 12, 2456–2466 (2012)10.3390/s120302456 ↗