journal article·2020-09Open access

Microstructure, mechanical properties, degradation behavior, and biocompatibility of porous Fe-Mn alloys fabricated by sponge impregnation and sintering techniques

Peifeng Liu, Dechuang Zhang, Yilong Dai, Jianguo Lin, Yuncang Li, Cuie Wen

Acta Biomaterialia· Volume 114

Abstract

In this study, porous iron (Fe)-manganese (Mn) alloys with high porosity were successfully prepared by sponge impregnation and sintering (SIS). The compositions of the porous Fe-Mn alloys were strongly dependent on the sintering temperature, and the Mn content was ~44, 30, and 12 wt.% for alloys sintered at 1100, 1150, and 1200 °C, respectively. The porous Fe-Mn alloys exhibited a well-interconnected porous structure with ~85% porosity and average pore size ranging from 375 to 500 um. The porous Fe-44Mn and Fe-30Mn alloys were mainly composed of a γ-austenite phase, while the porous Fe-12Mn was composed of an α-ferrite phase. The yield strength and elastic modulus of the porous Fe-Mn alloys ranged from 6 to 10 MPa and from 0.12 to 0.37 GPa, respectively, similar to those of cancellous bone. The degradation rate of the porous Fe-Mn alloys decreased over time during immersion in simulated body fluid (SBF), and was 1.0 mm/year for Fe-44Mn, 0.81 mm/year for Fe-30Mn, 0.41 mm/year for Fe-12Mn, and 0.33 mm/year for pure Fe after 14 d SBF immersion. Moreover, the porous Fe-Mn alloys exhibited good biocompatibility with clearly enhanced cell proliferation after direct culturing of osteoblastic MC3T3-E1 cells for 7 d. Thus, these porous Fe-Mn alloys can be anticipated to be promising biodegradable implant materials. STATEMENT OF SIGNIFICANCE: This work reports on porous Fe-Mn alloys with high porosity, suitable mechanical properties and degradation rate, and good biocompatibility. The porous alloys prepared by sponge impregnation and sintering exhibited a well-interconnected porous structure with ~85% porosity and average pore size ranging from 375 to 500 um. The yield strength and elastic modulus of the porous alloys ranged from 6 to 10 MPa and from 0.12 to 0.37 GPa, respectively, similar to those of cancellous bone. The degradation rates in simulated body fluid (SBF) were ~1.0 mm/year for Fe-44Mn, 0.81 mm/year for Fe-30Mn, and 0.41 mm/year for Fe-12Mn, respectively. Moreover, the porous Fe-Mn alloys exhibited good biocompatibility with enhanced cell proliferation after direct culturing of osteoblastic MC3T3-E1 cells.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Magnesium Alloys: Properties and Applications · Aluminum Alloys Composites Properties · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (63)

Show source-provided references
1. Ti based biomaterials, the ultimate choice for orthopaedic implants, a review10.1016/j.pmatsci.2008.06.004 ↗
2. Titanium alloys for biomedical applications
3. Biodegradable stents as a platform to drug loading10.1080/14628840304609 ↗
4. Iron and iron-based alloys for temporary cardiovascular applications10.1007/s10856-015-5473-8 ↗
5. The road to bioabsorbable stents: reaching clinical reality?10.1007/s00270-004-0341-9 ↗
6. Magnesium and its alloys as orthopedic biomaterials: a review10.1016/j.biomaterials.2005.10.003 ↗
7. The role of iron on the degradation and mineralization of organic compounds using conventional Fenton and photo-Fenton processes10.1016/j.cej.2009.08.020 ↗
8. Assessing the biocompatibility of degradable metallic materials: state-of-the-art and focus on the potential of genetic regulation10.1016/j.actbio.2010.02.027 ↗
9. Revolutionizing biodegradable metals10.1016/S1369-7021(09)70273-1 ↗
10. Long-term in vivo corrosion behavior, biocompatibility and bioresorption mechanism of a bioresorbable nitrided iron scaffold10.1016/j.actbio.2017.03.020 ↗
11. Are resorbable implants about to become a reality?10.1017/S1047951106000011 ↗
12. Long-term biocompatibility of a corrodible peripheral iron stent in the porcine descending aorta10.1016/j.biomaterials.2006.05.029 ↗
13. In vitro corrosion, cytotoxicity and hemocompatibility of bulk nanocrystalline pure iron10.1088/1748-6041/5/6/065015 ↗
14. Design strategy for biodegradable Fe-based alloys for medical applications10.1016/j.actbio.2009.07.039 ↗
15. Updates on the research and development of absorbable metals for biomedical applications10.1007/s40204-018-0091-4 ↗
16. Biodegradable metals10.1016/j.mser.2014.01.001 ↗
17. Corrosion and Mechanical Behavior of Biodegradable Metallic Biomaterials10.4028/www.scientific.net/SSP.227.431 ↗
18. Austenite stability and mechanical properties of nanocrystalline Fe-Mn alloy fabricated by spark plasma sintering with variable Mn content10.1016/j.msea.2018.04.051 ↗
19. Degradable metallic biomaterials: design and development of Fe-Mn alloys for stents10.1002/jbm.a.32224 ↗
20. Development of Degradable Fe-35Mn Alloy for Biomedical Application10.4028/www.scientific.net/AMR.15-17.107 ↗
21. Iron-manganese: new class of metallic degradable biomaterials prepared by powder metallurgy10.1179/174329008X284868 ↗
22. Fe-Mn alloys for metallic biodegradable stents: degradation and cell viability studies10.1016/j.actbio.2009.11.025 ↗
23. Novel Fe-Mn-Si-Pd alloys: insights into mechanical, magnetic, corrosion resistance and biocompatibility performances10.1039/C6TB01951J ↗
24. Sintering behaviour, graded microstructure and corrosion performance of sintered Fe-Mn biomaterials10.1016/S1452-3981(23)11175-8 ↗
25. Mechanical properties, corrosion performance and cell viability studies on newly developed porous Fe-Mn-Si-Pd alloys10.1016/j.jallcom.2017.07.112 ↗
26. 3D microenvironment as essential element for osteoinduction by biomaterials10.1016/j.biomaterials.2004.09.056 ↗
27. Osteoinduction of porous bioactive titanium metal10.1016/S0142-9612(03)00551-9 ↗
28. Structural and material design of open-cell powder metallurgical foams10.1002/adem.201100023 ↗
29. Iron based cellular structures-status and prospects10.1002/adem.200600078 ↗
30. ASTMB962-13. Standard Test Methods for Density of Compacted or Sintered Powder Metallurgy (PM) Products Using Archimedes'Principle, 2013.
31. ASTMAE9-89a. Standard Test Methods of Compression Testing of Metallic Materials at Room Temperature, 2000.
32. How useful is SBF in predicting in vivo bone bioactivity?10.1016/j.biomaterials.2006.01.017 ↗
33. ASTMG31-72. Standard Practice for Laboratory Immersion Corrosion Testing of Metals, 2004.
34. ISO 8407:1991. Corrosion of metals and alloys—Removal of corrosion products from corrosion test specimens, 1991.
35. ASTMWestConshohocken, PA. Standard Guide for Laboratory Immersion Corrosion Testing of Metals, 2012.
36. ISO 10993-5:2009. Biological evaluation of Medical Devices-Part 5: tests for In Vitro Cytotoxicity, 2009.
37. Manganese in ferrous powder metallurgy
38. Weight loss behavior of a vacuum sintered powder metallurgical Fe-Mn-Si alloy10.1557/jmr.2016.506 ↗
39. Scaffolds in tissue engineering bone and cartilage10.1016/S0142-9612(00)00121-6 ↗
40. Processing of biocompatible porous Ti and Mg10.1016/S1359-6462(01)01132-0 ↗
41. Novel titanium foam for bone tissue engineering10.1557/JMR.2002.0382 ↗
42. Degradable porous Fe-35wt.%Mn produced via powder sintering from NH4HCO3 porogen10.1016/j.matchemphys.2015.07.056 ↗
43. Exploring the Role of Manganese on the Microstructure, Mechanical Properties, Biodegradability, and Biocompatibility of Porous Iron-Based Scaffolds10.1021/acsbiomaterials.8b01497 ↗
44. Mechanical behavior of metallic foams10.1146/annurev.matsci.30.1.191 ↗
45. Gibson · 1999
46. Bioresorbable Fe-Mn and Fe-Mn-HA materials for orthopedic implantation: enhancing degradation through porosity control10.1002/adhm.201700120 ↗
47. Evolution of metallic cardiovascular stent materials: a comparative study among stainless steel, magnesium and zinc10.1016/j.biomaterials.2019.119641 ↗
48. Mechanical Strength, Biodegradation, and in Vitro and in Vivo Biocompatibility of Zn Biomaterials10.1021/acsami.8b20634 ↗
49. Effect of microstructure and strain on the degradation behavior of novel bioresorbable iron-manganese alloy implants10.1002/jbm.a.35220 ↗
50. Investigation of porosity on mechanical properties, degradation and in-vitro cytotoxicity limit of Fe30Mn using space holder technique10.1016/j.msec.2019.02.055 ↗
51. Degradation performance of biodegradable FeMnC (Pd) alloys10.1016/j.msec.2012.10.013 ↗
52. Additively manufactured iron-manganese for biodegradable porous load-bearing bone scaffold applications10.1016/j.actbio.2019.12.018 ↗
53. A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal-results 6-18 months after implantation into New Zealand white rabbits10.1136/heart.86.5.563 ↗
54. Fe-Mn alloys for metallic biodegradable stents: degradation and cell viability studies10.1016/j.actbio.2009.11.025 ↗
55. In vitro and in vivo corrosion properties of new iron-manganese alloys designed for cardiovascular applications10.1002/jbm.b.33234 ↗
56. Ellenhorn's Medical Toxicology: diagnosis and Treatment of Human Poisoning10.1001/jama.1997.03550140095052 ↗
57. Relevance, essentiality and toxicity of trace elements in human health10.1016/j.mam.2005.07.013 ↗
58. Manganese exposure, essentiality & toxicity
59. Manganese: recent advances in understanding its transport and neurotoxicity10.1016/j.taap.2007.03.001 ↗
60. In Vivo Evaluation of Biodegradability and Biocompatibility of Fe30Mn Alloy10.3415/VCOT-17-06-0080 ↗
61. R. Waksman, R. Pakala, R. BaffourR, Short-term effects of biocorrodible iron stents in porcine coronary arteries, J Interv. Cardiol.21(2008) 15.10.1111/j.1540-8183.2007.00319.x ↗
62. Binder-jetting 3D printing and alloy development of new biodegradable Fe-Mn-Ca/Mg alloys10.1016/j.actbio.2016.08.032 ↗
63. Fe-Mn-Cu alloy as biodegradable material with enhanced antimicrobial properties10.1016/j.matlet.2018.11.117 ↗