Abstract

Abstract One of the most effective oral antipyretics and analgesics, ibuprofen (IBP) is a primary ingredient in hospital wastewater because it is widely used to treat both acute and chronic pain. It is important to detect its concentration in the wastewater. Bio-electrochemical sensor is a promising detection method due to its durability and accuracy. Schiffbase is an advanced electrode materials for bio-electrochemical sensor. Which able to detect (IBP) concentration in wastewater.2,3dihydroxy-N'1-((E)-2-hydroxybenzylidene)-N'4-((Z)-2-hydroxybenzylidene (Schiffbase) materials have been synthesized and characterized.IR spectroscopy data identified (OH/H2O), ʋ (H-bonding), ʋ (C = O), ʋ (COH), ʋ (C = N) function groups. The SEM images of Schiff base presented needle-like shape with regular morphology. Electrochemical electrode have been fabricated from Schiffbase materials. IBP detected electrochemically by CV, DPV, and EIS methods, sensing rate of (2E−7 A/mgL−1) with coefficient of determination was (R2 = 0.999), into two steps sensing mechanism, which correspond to the ion diffusion process, respectively. Schiffbase electrodes shows superior sensitivity for low concentration of IBP (~ 2 mg/L). Sensing mechanism proposed upon electrochemical results.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Analytical Chemistry and Sensors · Electrochemical Analysis and Applications · Electrochemical sensors and biosensors

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Kumari, A., Maurya, N. S., & Tiwari, B. (2020). Hospital wastewater treatment scenario around the globe. In Elsevier eBooks (pp. 549–570). https://doi.org/10.1016/b978-0-12-819722-6.00015-810.1016/b978-0-12-819722-6.00015-8 ↗
2. J. Cai, V. Murugadoss, J. Jiang, X. Gao, Z. Lin, M. Huang, J. Guo, S.A. Alsareii, H. Algadi, M. Kathiresan, Waterborne polyurethane and its nanocomposites: a mini-review for anti-corrosion coating, flame retardancy, and biomedical applications. Adv. Compos. and Hybrid Mater. 5(2), 641–650 (2022). https://doi.org/10.1007/s42114-022-00473-810.1007/s42114-022-00473-8 ↗
3. Y. Kwak, P. Colque, S. Byfors, C.G. Giske, R. Möllby, I. Kühn, Surveillance of antimicrobial resistance among Escherichia coli in wastewater in Stockholm during 1 year: does it reflect the resistance trends in the society? Int. J. Antimicrob. Agents 45(1), 25–32 (2015). https://doi.org/10.1016/j.ijantimicag.2014.09.01610.1016/j.ijantimicag.2014.09.016 ↗
4. U. Nielsen, C. Hastrup, M.M. Klausen, B.M. Pedersen, G.H. Kristensen, J.L.C. Jansen, S.N. Bak, J. Tuerk, Removal of APIs and bacteria from hospital wastewater by MBR plus O3, O3 + H2O2, PAC or ClO2. Water Sci. Technol. 67(4), 854–862 (2013). https://doi.org/10.2166/wst.2012.64510.2166/wst.2012.645 ↗
5. L.T.Q. Lien, N.Q. Hoa, N.T.K. Chuc, N.T.M. Thoa, H.D. Phuc, V. Diwan, N.T. Dat, A.J. Tamhankar, C.S. Lundborg, Antibiotics in wastewater of a rural and an Urban hospital before and after Wastewater treatment, and the relationship with antibiotic use—a one year study from Vietnam. Int. J. Environ. Res. and Public Health/Int. J. Environ. Res. and Public Health 13(6), 588 (2016). https://doi.org/10.3390/ijerph1306058810.3390/ijerph13060588 ↗
6. S. Dires, T. Birhanu, A. Ambelu, G. Sahilu, Antibiotic resistant bacteria removal of subsurface flow constructed wetlands from hospital wastewater. J. Environ. Chem. Eng. 6(4), 4265–4272 (2018). https://doi.org/10.1016/j.jece.2018.06.03410.1016/j.jece.2018.06.034 ↗
7. P. Verlicchi, M.A. Aukidy, E. Zambello, What have we learned from worldwide experiences on the management and treatment of hospital effluent? — An overview and a discussion on perspectives. Sci. Total Environ. 514, 467–491 (2015). https://doi.org/10.1016/j.scitotenv.2015.02.02010.1016/j.scitotenv.2015.02.020 ↗
8. M. Von Sperling, C.A. De Lemos Chernicharo, Biological wastewater treatment in warm climate regions (IWA Publishing, London, 2005)
9. D. Periasamy, A. Sundaram, A novel approach for pathogen reduction in wastewater treatment. J. Environ. Health Sci. & Eng. (2013). https://doi.org/10.1186/2052-336x-11-1210.1186/2052-336x-11-12 ↗
10. A. Majumder, B. Gupta, A.K. Gupta, Pharmaceutically active compounds in aqueous environment: a status, toxicity and insights of remediation. Environ. Res. 176, 108542 (2019). https://doi.org/10.1016/j.envres.2019.10854210.1016/j.envres.2019.108542 ↗
11. E. El-Maghraby, M.H. Ashery, M. Elnouby, E. Elsehly, Vanadium oxides nanostructures for adsorption of Methylene blue, vehicle exhaust and soot of ink as low carbon applications. Results Opt. 16, 100673 (2024). https://doi.org/10.1016/j.rio.2024.10067310.1016/j.rio.2024.100673 ↗
12. A.I. Osman, A. Ayati, M. Farghali, P. Krivoshapkin, B. Tanhaei, H. Karimi-Maleh, E. Krivoshapkina, P. Taheri, C. Tracey, A. Al-Fatesh, I. Ihara, D.W. Rooney, M. Sillanpaä, Advanced adsorbents for ibuprofen removal from aquatic environments: a review. Environ. Chem. Lett. 22(1), 373–418 (2023). https://doi.org/10.1007/s10311-023-01647-610.1007/s10311-023-01647-6 ↗
13. E. El-Maghraby, M.H. Ashery, M. Elnouby, E. Elsehly, Vanadium oxides nanostructures for adsorption of Methylene blue, vehicle exhaust and soot of ink as low carbon applications. Results Opt. 16, 100673 (2024). https://doi.org/10.1016/j.rio.2024.10067310.1016/j.rio.2024.100673 ↗
14. B. Mekassa, M. Tessema, B.S. Chandravanshi, M. Tefera, Square wave voltammetric determination of ibuprofen at Poly(L-Aspartic acid) modified glassy carbon electrode. IEEE Sens. J. 18(1), 37–44 (2018). https://doi.org/10.1109/jsen.2017.276913710.1109/jsen.2017.2769137 ↗
15. R. Jamal, Y. Liu, A. Abdurexit, N. Sawut, Y. Yan, A. Ali, T. Abdiryim, Electrochemical sensor for detection of paracetamol based on pendent nitrogen heterocyclicRing-Functionalizedpolyterthiophene derivatives. ChemistrySelect 6(18), 4473–4481 (2021). https://doi.org/10.1002/slct.20210006510.1002/slct.202100065 ↗
16. G. Hanbali, S. Jodeh, O. Hamed, R. Bol, B. Khalaf, A. Qdemat, S. Samhan, Enhanced ibuprofen adsorption and desorption on synthesized functionalized magnetic multiwall carbon nanotubes from aqueous solution. Materials 13(15), 3329 (2020). https://doi.org/10.3390/ma1315332910.3390/ma13153329 ↗
17. W.D. Rengga, N.A. Imani, N. Wijayati, T. Tohiran, W.H. Cahyati, D. Saputra, Adsorption and release of ibuprofen from silica-carbon composites based on rice husks (Oryza Sativa) and banana peels (Musa Acuminata). Eng. Sci. (2023). https://doi.org/10.30919/es8d87310.30919/es8d873 ↗
18. E.E. Ammar, A.A.S. Sayed, M. M. Rabee, A.E. Keshta, M.G. Daher, G.A.M. Ali, Environmental and agricultural applications of sensors book, in Handbook of nanosensors: materials and technological applications. ed. by G.A.M. Ali, K.F. Chong, S.H. Abdel (Springer Nature Switzerland, Cham, 2024)
19. R. Ranjan, B.C. Sahana, A comprehensive roadmap for transforming healthcare from hospital-centric to patient-centric through healthcare internet of things (IoT). Eng. Sci. (2024). https://doi.org/10.30919/es117510.30919/es1175 ↗
20. D. Grieshaber, R. MacKenzie, J. Vörös, E. Reimhult, Electrochemical biosensors - sensor principles and architectures. Sensors 8(3), 1400–1458 (2008). https://doi.org/10.3390/s803140010.3390/s8031400 ↗
21. S. Kaur, J. Kaur, J. Sharma, I. Kaur, S-S bridged Schiff bases as versatile ionophores: synthesis and application for electrochemical sensing of Copper(II) and Mercury(II). Anal. Chim. Acta 1287, 342122 (2024). https://doi.org/10.1016/j.aca.2023.34212210.1016/j.aca.2023.342122 ↗
22. J. Gayathri, S. Sivalingam, S.S. Narayanan, Synthesis and characterization of Schiff base ligand-mutliwalled carbon nanotubes as mercury-free electrochemical sensor for detecting toxic metals in aquatic treatment. Diam. Relat. Mater. 136, 109984 (2023). https://doi.org/10.1016/j.diamond.2023.10998410.1016/j.diamond.2023.109984 ↗
23. D. Nowicka, M. Kubicki, V. Patroniak, T. Łuczak, A. Gorczyński, Self-assembly of simple Schiff base ligand into unique saddle-type [4x4] tetranuclear architecture and its application as selective voltammetric dopamine sensor in aqueous conditions. ElectrochimicaActa 476, 143754 (2024). https://doi.org/10.1016/j.electacta.2023.14375410.1016/j.electacta.2023.143754 ↗
24. S. Sarwar, M. Lin, C. Amezaga, Z. Wei, E. Iyayi, H. Polk, R. Wang, H. Wang, X. Zhang, Ultrasensitive electrochemical biosensors based on zinc sulfide/graphene hybrid for rapid detection of SARS-CoV-2. Adv. Compos. Hybrid Mater. (2023). https://doi.org/10.1007/s42114-023-00630-710.1007/s42114-023-00630-7 ↗
25. R. Gupta, M. Yadav, S. Singh, V. Ganesan, B. Singh, Design and development of a multiwalled carbon nanotubes-based copper (II) Schiff base complex for the facile non-enzymatic electrochemical sensing of glucose. J. Mater. Sci. 58(30), 12312–12330 (2023). https://doi.org/10.1007/s10853-023-08774-z10.1007/s10853-023-08774-z ↗
26. C. Liu, X. Wei, X. Wang, J. Shi, Z. Chen, H. Zhang, W. Zhang, X. Zou, Ratiometric electrochemical analysis on a flexibly-fabricated vibratory electrode module for reliable and selective determination of imidacloprid. Sens. and Actuators B Chem. 329, 129228 (2021). https://doi.org/10.1016/j.snb.2020.12922810.1016/j.snb.2020.129228 ↗
27. S.S. Rikame, A.A. Mungray, A.K. Mungray, Modification of anode electrode in microbial fuel cell for electrochemical recovery of energy and copper metal. ElectrochimicaActa 275, 8–17 (2018). https://doi.org/10.1016/j.electacta.2018.04.14110.1016/j.electacta.2018.04.141 ↗
28. C. Liu, X. Wei, X. Wang, J. Shi, Z. Chen, H. Zhang, W. Zhang, X. Zou, Ratiometric electrochemical analysis on a flexibly-fabricated vibratory electrode module for reliable and selective determination of imidacloprid. Sens. and Actuators B Chem. 329, 129228 (2021). https://doi.org/10.1016/j.snb.2020.12922810.1016/j.snb.2020.129228 ↗
29. E. Casero, A. Parra-Alfambra, M. Petit-Domínguez, F. Pariente, E. Lorenzo, C. Alonso, Differentiation between graphene oxide and reduced graphene by electrochemical impedance spectroscopy (EIS). Electrochem. Commun. 20, 63–66 (2012). https://doi.org/10.1016/j.elecom.2012.04.00210.1016/j.elecom.2012.04.002 ↗
30. G.A. Elbaz, H.E. Zaazaa, H.H. Monir, L.M. Halim, a. E., & Atty, S. A., Nano eco-friendly voltammetric determination of pesticide, imidacloprid and its residues in thyme and guava leaves. Sustain. Chem. and Pharmacy 29, 100799 (2022). https://doi.org/10.1016/j.scp.2022.10079910.1016/j.scp.2022.100799 ↗
31. R. Jamal, Y. Liu, A. Abdurexit, N. Sawut, Y. Yan, A. Ali, T. Abdiryim, Electrochemical sensor for detection of paracetamol based on pendent nitrogenheterocyclic Ring-Functionalized polyterthiophene derivatives. ChemistrySelect 6(18), 44734481 (2021). https://doi.org/10.1002/slct.20210006510.1002/slct.202100065 ↗
32. K. Tyszczuk-Rotko, J. Kozak, A. Węzińska, Electrochemically activated Screen-Printed carbon electrode for determination of ibuprofen. Appl. Sci. 11(21), 9908 (2021). https://doi.org/10.3390/app1121990810.3390/app11219908 ↗
33. S. Amin, M.T. Soomro, N. Memon, A.R. Solangi, N. Sirajuddin, T. Qureshi, A.R. Behzad, Disposable screen printed graphite electrode for the direct electrochemical determination of ibuprofen in surface water. Environ. Nanotechnol., Monit. & Manag. 1–2, 8–13 (2014). https://doi.org/10.1016/j.enmm.2014.07.00110.1016/j.enmm.2014.07.001 ↗