Detection of creatinine via fast electrode-based nanosensor templated by functional carbon nanotubes
Bibliographic record
Abstract
No abstract is available for this record. The assistant can identify its topic from the title, but cannot infer the study’s results.
Source: Not provided · Quality: missing
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Biosensors and Analytical Detection · Carbon and Quantum Dots Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (84)
Show source-provided references
1. C.S. Pundir, S. Yadav, A. Kumar, Creatinine sensors. TrAC Trends Anal. Chem. 50, 42–52 (2013)10.1016/j.trac.2013.04.013 ↗
2. O. Begou, K. Weber, B. Beckmann, D. Tsikas, GC-MS studies on derivatization of creatinine and creatine by BSTFA and their measurement in human urine. Molecules 26(11), 3206 (2021)10.3390/molecules26113206 ↗
3. C.L. Gonzalez-Gallardo, N. Arjona, L. Álvarez-Contreras, M. Guerra-Balcázar, Electrochemical creatinine detection for advanced point-of-care sensing devices: a review. RSC Adv. 12, 30785–30802 (2022)10.1039/D2RA04479J ↗
4. C.S. Pundir, P. Kumar, R. Jaiwal, Biosensing methods for determination of creatinine: a review. Biosens. Bioelectron. 126, 707–724 (2019)10.1016/j.bios.2018.11.031 ↗
5. S.N. Prabhu, S.C. Mukhopadhyay, G. Liu, Sensors and techniques for creatinine detection: a review. IEEE Sensors J. 22(12), 11427–11438 (2022)10.1109/JSEN.2022.3174818 ↗
6. N. Prasad, M.R. Patel, Infection-induced kidney diseases. Front. med. 5, 327 (2018)10.3389/fmed.2018.00327 ↗
7. L. Caporossi, E. Paci, S. Capanna, B. Papaleo, G. Tranfo, D. Pigini, A new HPLC-MS/ MS method for urinary creatinine determination: comparison study with Jaffè’s method. Urine 5, 23–28 (2023)10.1016/j.urine.2023.04.002 ↗
8. P.J. Babu, A. Tirkey, T.J.M. Rao, N.B. Chanu, K. Lalchhandama, Y.D. Singh, Conventi- onal and nanotechnology based sensors for creatinine (a kidney biomarker) detection: a consolidated review. Anal. Biochem. 645, 114622 (2022)10.1016/j.ab.2022.114622 ↗
9. K. Syal, D. Banerjee, A. Srinivasan, Creatinine estimation and interference. Ind. J. Clin. Biochem. 28(2), 210–211 (2013)10.1007/s12291-013-0299-y ↗
10. S. Caliskan, E. Yildirim, D.A. Anakok, S. Cete, Design of a new biosensor platform for creatinine determination. J. Solid State Electrochem. 26, 549–557 (2022)10.1007/s10008-021-05107-5 ↗
11. C.A.H.M. Enamullah, L.C. Ghosh, G.M.H. Rahman, M.S. Hossain, F. Jesmin, T. Jahan, A. Sikdar, Role of ultrasound in diagnosing chronic kidney disease (CKD). Saudi J. Med. 8(9), 505–510 (2023)10.36348/sjm.2023.v08i09.006 ↗
12. H. Helena, V. Ivona, Ř Roman, F. František, Current applications of capillary electro phoresis-massspectrometry for the analysis of biologically important analytes in urine (2017 to mid-2021): a review. J. Sep. Sci. 45(1), 2–393 (2022)10.1002/jssc.202100621 ↗
13. J. Wang, M. Zha, H. Zhao, W. Yue, D. Wu, K. Li, Detection of kidney dysfunction through in vivo magnetic resonance imaging with renal-clearable gadolinium nano probes. Anal. Chem. 94(9), 4005–4011 (2022)10.1021/acs.analchem.1c05140 ↗
14. N. Nontawong, M. Amatatongchai, S. Thimoonnee, S. Laosing, P. Jarujamrus, C. Karuwan, S. Chairam, Novel amperometric flow-injection analysis of creatinine using a molecularly-imprinted polymer coated copper oxide nanoparticle-modified carbon-paste-electrode. J. Pharm. Biomed. Anal. 175, 112770 (2019)10.1016/j.jpba.2019.07.018 ↗
15. R.K.R. Kumar, M.O. Shaikh, A. Kumar, C.H. Liu, C.H. Liu, C.H. Chuang, Zwitterion-functionalized cuprous oxide nanoparticles for highly specific and enzymeless electro chemical creatinine biosensing in human serum. ACS Appl. Nano Mater. 6(3), 2083–2094 (2023)10.1021/acsanm.2c05020 ↗
16. A. Post, E. Garcia, I. Shalaurova, S.P. Matyus, J.M.G. Delgado, C.S.E. Doorenbos, Y.V.D. Veen, S.H. Shah, W.E. Kraus, D. Kremer, T.J. Knobbe, S.J.L. Bakker, R.P.F. Dullaart, M.A. Connelly, Creatine and creatinine quantified using nuclear magnetic resonance: a method validation study and clinical associations between circulating creatine and fatigue in kidney transplant recipients. Clin. Chim. Acta 548, 117517 (2023)10.1016/j.cca.2023.117517 ↗
17. J. Sun, H. Yang, W. Cai, J. Zheng, N. Shen, X. Yang, B. Pan, W. Zhang, X. Chen, X. Shen, Serum creatinine/cystatin C ratio as a surrogate marker for sarcopenia in patients with gastric cancer. BMC Gastroenterol. 22, 26 (2022)10.1186/s12876-022-02093-4 ↗
18. R. Wahab, F. Khan, M. Alam, Y.K. Mishra, Silver nanoparticle based selective, sensi- tive and instantaneous electrochemical nanosensors for the analysis of riboflavin. Mater. Sci. Semicond. Process. 153, 107166 (2023)10.1016/j.mssp.2022.107166 ↗
19. A. Whaley-Connell, R. Nistala, K. Chaudhary, The Importance of early identification of chronic kidney disease. Mo. Med. 108(1), 25–28 (2011)
20. P. Devarajan, Biomarkers for the early detection of acute kidney injury. Curr. Opin. Pediatr. 23(2), 194–200 (2011)10.1097/MOP.0b013e328343f4dd ↗
21. R. Ram, D. Kumar, A. Sarkar, A smartphone-integrated portable rotating platform for estimation of concentration level of plasma-creatinine using whole human blood. Talanta 253, 123960 (2023)10.1016/j.talanta.2022.123960 ↗
22. D. Mehta, A. Kaflea, T.C. Nagaiah, Flexible electrochemical sensor for highly sensi- tive and selective non-enzymatic detection of creatinine via electrodeposited copper over poly melamine formaldehyde. J. Mater. Chem. B 11, 11103–11109 (2023)10.1039/D3TB01528A ↗
23. S.N. Ashakirin, M.H.M. Zaid, M.A.S.M. Haniff, A. Masood, M.F.M.R. Wee, Sensitive electrochemical detection of creatinine based on electrodeposited molecular imprinting polymer modified screen printed carbon electrode. Measurement 210, 112502 (2023)10.1016/j.measurement.2023.112502 ↗
24. T.M. Adeniji, K.J. Stine, Nanostructure modified electrodes for electrochemical detection of contaminants of emerging concern. Coatings 13(2), 381 (2023)10.3390/coatings13020381 ↗
25. S. Jampasa, W. Khamcharoen, S. Traipop, W. Jesadabundit, T. Ozer, O. Chailapakul, Recent advances on nanomaterial-modified film-electrode-based sensors: approach to clinical purpose. Curr. Opin. Electrochem. 42, 101420 (2023)10.1016/j.coelec.2023.101420 ↗
26. A. Abbas, H.M.A. Amin, Silver nanoparticles modified electrodes for electroanalysis: an updated review and a perspective. Microchem. J. 175, 107166 (2022)10.1016/j.microc.2021.107166 ↗
27. P. Bertoncello, R.J. Forster, Nanostructured materials for electrochemiluminescence (ECL)-based detection methods: recent advances and future perspectives. Biosens. Bioelectron. 24(11), 3191–3200 (2009)10.1016/j.bios.2009.02.013 ↗
28. N. Baig, M. Sajid, T.A. Saleh, Recent trends in nanomaterial-modified electrodes for electroanalytical applications. TrAC Trends Anal. Chem. 111, 47–61 (2019)10.1016/j.trac.2018.11.044 ↗
29. F.A. Azri, R. Sukor, R. Hajian, N.A. Yusof, F.A. Bakari, J. Selamati, Modification strategy of screen-printed carbon electrode with functionalized multi-walled carbon nanotube and chitosan matrix for biosensor development. Asian J. Chem. 29(1), 31–36 (2017)10.14233/ajchem.2017.20104 ↗
30. A.J.S. Ahammad, J.J. Lee, M.A. Rahman, Electrochemical sensors based on carbon nanotubes. Sensors (Basel) 9(4), 2289–2319 (2009)10.3390/s90402289 ↗
31. P. Yáñez-Sedeño, J.M. Pingarrón, J. Riu, F.X. Rius, Electrochemical sensing based on carb- on nanotubes. TrAC Trends Anal. Chem. 29(9), 939–953 (2010)10.1016/j.trac.2010.06.006 ↗
32. S.K. Prajapati, A. Malaiya, P. Kesharwani, D. Soni, A. Jain, Biomedical applications and toxicities of carbon nanotubes. Drug. Chem. Toxicol. 45, 435–450 (2022)10.1080/01480545.2019.1709492 ↗
33. M.R. Venkatraman, N. Muthukumarasamy, R. Balasundaraprabhu, S. Agilan, D. Velauthapillai, Solvothermal synthesis of TiO2/CNT composites and its physical and chemical properties. AIP Conf. Proc. 1665, 050166 (2015)10.1063/1.4917807 ↗
34. S. Singh, W. Oum, S.S. Kim, H.W. Kim, Functionalized multiwalled carbon nanotubes for highly stable room temperature and humidity-tolerant triethylamine sensing. ACS Sens. 8(12), 4664–4675 (2023)10.1021/acssensors.3c01721 ↗
35. M. Ali, R. Riaz, A.S. Anjum, K.C. Sun, H. Li, S.J. Ahn, S.H. Jeong, M.J. Ko, Microwave-assisted ultrafast in-situ growth of N-doped carbon quantum dots on multiwalled carbon nanotubes as an efficient electrocatalyst for photovoltaics. J. Colloid Interface Sci. 586, 349–361 (2021)10.1016/j.jcis.2020.10.098 ↗
36. S. Wang, Y. Huang, E. Chang, C. Zhao, A. Ameli, H.E. Nagui, C.B. Park, Evaluation and modeling of electrical conductivity in conductive polymer nanocomposite foams with multiwalled carbon nanotube networks. Chemical Engg J 411, 128382 (2021)10.1016/j.cej.2020.128382 ↗
37. S. Shahrokhian, L. Naderi, M. Ghalkhani, Modified glassy carbon electrodes based on carbon nanostructures for ultrasensitive electrochemical determination of furazolidone. Mater. Sci. Eng. C 61, 842–850 (2016)10.1016/j.msec.2016.01.025 ↗
38. R. Wahab, S.G. Ansari, Y.S. Kim, T.R. Mohanty, I.H. Hwang, H.S. Shin, Immobilization of DNA on nanohydroxyapatite and their interaction with carbon nanotubes. Synt Metals 159, 238–234 (2009)10.1016/j.synthmet.2008.09.016 ↗
39. Y. Ando, X. Zhao, H. Shimoyama, G. Sakai, K. Kaneto, Physical properties of multi walled carbon nanotubes. Int. J. Inorg. Mater. 1(1), 77–82 (1999)10.1016/S1463-0176(99)00012-5 ↗
40. P.P. Komane, P. Kumar, T. Marimuthu, L.C.D. Toit, P.P.D. Kondiah, Y.E. Choonara, V. Pillay, Dexamethasone-loaded, PEGylated, vertically aligned, multiwalled carbon nano tubes for potential ischemic stroke intervention. Molecules 23(6), 1406 (2018)10.3390/molecules23061406 ↗
41. H.M. Marwani, J. Ahmed, M.M. Rahman, Development of a toxic lead ionic sensor using carboxyl-functionalized MWCNTs in real water sample analyses. Sensors (Basel) 22(22), 8976 (2022)10.3390/s22228976 ↗
42. R.O. Cristóvão, R.A.M. Barros, J.G. Pinho, L.S. Teixeira, M.C. Neves, M.G. Freire, J.L. Faria, V.C. Santos-Ebinuma, A.P.M. Tavares, C.G. Silva, Unveiling the influence of carbon nanotube diameter and surface modification on the anchorage of L-Asparaginase. Appl. Sci. 12(17), 8924 (2022)10.3390/app12178924 ↗
43. T.L. Adewoye, O.O. Ogunleye, A.S. Abdulkareem, T.O. Salawudeen, J.O. Tijani, Optimi- zation of the adsorption of total organic carbon from produced water using functionalized multi-walled carbon nanotubes. Heliyon. 7(1), e05866 (2021)10.1016/j.heliyon.2020.e05866 ↗
44. Z. Bicil, Adsorptıon kinetics and mechanism of hydrogen on pristine and functionalized multi-walled carbon nanotubes. Fuel 403, 136130 (2026)10.1016/j.fuel.2025.136130 ↗
45. S.Z. Abidin, I.S. Mohamad, A.Y.B. Hashim, N. Abdullah, A. Abdullah, Textural and adsorption analysis of nanocarbon particles. Inter. J. Nanoelectron Mater 11(3), 293–304 (2018)
46. C.L. Chen, B. Liang, A. Ogino, X.K. Wang, M. Nagatsu, Oxygen functionalization of multiwall carbon nanotubes by microwave-excited surface-wave plasma treatment. J. Phys. Chem. C 113, 7659–7665 (2009)10.1021/jp9012015 ↗
47. X.Y. Chen, C. Chen, Z.J. Zhang, D.H. Xie, Gelatin-derived nitrogen-doped porous car- bon via a dual-template carbonization method for high performance supercapacitors. J. Mater. Chem. A 1, 10903–10911 (2013)10.1039/c3ta12328f ↗
48. O. Fasakin, K.O. Oyedotun, M. Kebede, M. Rohwer, L.L. Roux, M. Mathe, M.A. Eleruja, E.O.B. Ajayi, N. Manyala, Preparation and physico-chemical investigation of anatase TiO2 nanotubes for a stable anode of lithium-ion battery. Energy Rep. 6, 92–101 (2020)10.1016/j.egyr.2020.02.010 ↗
49. C. Labay, C. Canal, C. Rodríguez, G. Caballero, J.M. Canal, Plasma surface functiona- lization and dyeing kinetics of Pan-Pmma copolymers. Appl. Surf. Sci. 283, 269–275 (2013)10.1016/j.apsusc.2013.06.100 ↗
50. A. Kumar, S. Mondal, K.S.R.K. Rao, Tunable band alignment and dielectric constant of solution route fabricated Al/HfO2/Si gate stack for CMOS applications. J. Appl. Phys. 121, 085301 (2017)10.1063/1.4977007 ↗
51. X. Yao, Y. Fang, X. Cui, X. Cheng, Z. Cheng, Dielectric barrier discharge plasma coupled with cobalt oxyhydroxide for methylene blue degradation. Toxics 11, 763 (2023)10.3390/toxics11090763 ↗
52. D. Liu, J. Ji, X. Guo, S. Gou, X. Chen, Syringe paper-based analytical device for thiamazole detection by Hedysarum polysaccharides-mediated silver nanoparticles. Micromachines 14, 350 (2023)10.3390/mi14020350 ↗
53. R. Wahab, N. Ahmad, M. Alam, Silicon nanoparticles: a new and enhanced operational material for nitrophenol sensing. J. Mater. Sci. Mater. Electron. 31, 17084–17099 (2020)10.1007/s10854-020-04269-8 ↗
54. International Organization for Standardization Accuracy (1994) (Trueness and Precision) of measurement methods and results. ISO/DIS: 5725
55. D. Vega, L. Agüí, A. González-Cortés, P. Yáñez-Sedeño, J.M. Pingarrón, Voltammetry and amperometric detection of tetracyclines at multi-wall carbon nanotube modified electrodes. Anal. Bioanal. Chem. 398, 951–958 (2007)10.1007/s00216-007-1505-7 ↗
56. S.H. Lin, J.C. Wang, Z.H. Lin, F.C. Kao, H.Y. Wang, High-selectivity nonenzymatic creatinine sensor using electrografted ionic liquid and nafion for reliable clinical diagnostics. ACS Sensors 10(8), 6020–6028 (2025)10.1021/acssensors.5c01503 ↗
57. S.E. Ribault, A. Zebda, S. Tingry, M. Petit, A.L. Suherman, A. Boualam, P. Cinquin, D.K. Martin, Performance and stability of chitosan-MWCNTs-laccase biocathode: effect of MWCNTs surface charges and ionic strength. J. Electroanal. Chem. 799, 26–33 (2017)10.1016/j.jelechem.2017.05.018 ↗
58. Y. Vlamidis, I. Gualandi, D. Tonelli, Amperometric biosensors based on reduced GO and MWCNTs composite for polyphenols detection in fruit juices. J. Electroanal. Chem. 799, 285–292 (2017)10.1016/j.jelechem.2017.06.012 ↗
59. M.I. Malik, Z.O. Malaibari, M. Atieh, B. Abussaud, Electrochemical reduction of CO2 to methanol over MWCNTs impregnated with Cu2O. Chem Engg Sci. 152, 468–477 (2016)10.1016/j.ces.2016.06.035 ↗
60. K.Y. Hwa, T.S.K. Sharma, A. Ganguly, Design strategy of rGO–HNT–AgNPs based hybrid nanocomposite with enhanced performance for electrochemical detection of 4-nitrophenol. Inorg. Chem. Front. 7, 1981–1994 (2020)10.1039/D0QI00006J ↗
61. R.A. Nyquist, R.O. Kagel, Infrared Spectra of Inorganic Compounds (Academic Press Inc, New York, London, 1971)10.1016/B978-0-12-523450-4.50005-5 ↗
62. A.C. Lazanas, Prodromidis MI (2023) electrochemical impedance spectroscopy─a tutorial. ACS Meas. Sci. Au 3(3), 162–193 (2023)10.1021/acsmeasuresciau.2c00070 ↗
63. M.P.F. Graça, A. Rudnitskaya, F.A.C. Faria, D.V. Evtuguin, M.T.S.R. Gomes, J.A.B.P. Oliveira, L.C. Costa, Electrochemical impedance study of the lignin-derived conducting polymer. Electrochim. Acta 76, 69–76 (2012)10.1016/j.electacta.2012.04.155 ↗
64. S. Yadav, A. Kumar, C.S. Pundir, Amperometric creatinine biosensor based on covalently coimmobilized enzymes onto carboxylated multiwalled carbon nanotubes/ polyaniline composite film. Anal. Biochem. 419(2), 277–283 (2011)10.1016/j.ab.2011.07.032 ↗
65. S. Vengurlekar, S.C. Chaturvedi, Elevating toward a new innovation carbon nano tubes (CNTs). Biomedical Appl Nanoparticles (Ch-10) (2019). https://doi.org/10.1016/B978-0-12-816506-5.00016-410.1016/B978-0-12-816506-5.00016-4 ↗
66. S. Rathinavel, K. Priyadharshini, D. Panda, A review on carbon nanotube: an over view of synthesis, properties, functionalization, characterization, and the application. Mater. Sci. Eng. B 268, 115095 (2021)10.1016/j.mseb.2021.115095 ↗
67. R. Wahab, S.T. Khan, J. Ahmad, S.G. Ansari, J. Musarrat, A.A. Al-Khedhairy, MWCNTs functionalization and immobilization with anti-Brucella antibody; towards the development of a nanosensor. Vacuum 146, 623–632 (2017)10.1016/j.vacuum.2017.01.022 ↗
68. D. Holmannova, P. Borsky, T. Svadlakova, L. Borska, Z. Fiala, Carbon nano particles and their biomedical applications. Appl. Sci. 12(15), 7865 (2022)10.3390/app12157865 ↗
69. A.M. Fekry, S.A. Abdel-Gawad, R.H. Tammam, M.A. Zayed, An electrochemical sensor for creatinine based on carbon nanotubes/folic acid/silver nanoparticles modified electrode. Measurement 163, 107958 (2020)10.1016/j.measurement.2020.107958 ↗
70. C.L. Gonzalez-Gallardo, N. Arjona, L. Alvarez-Contreras, M. Guerra-Balcazar, Electro chemical creatinine detection for advanced point-of-care sensing devices: a review. RSC Adv. 12, 30785 (2022)10.1039/D2RA04479J ↗
71. S.G. Ansari, Z.A. Ansari, R. Wahab, Y.S. Kim, G. Khang, H.S. Shin, Glucose sensor based on nano-baskets of tin oxide templated in porous alumina by plasma enhanced CVD. Biosens. Bioelectron. 23, 1838–1842 (2008)10.1016/j.bios.2008.02.022 ↗
72. H. Farahani, R. Wagiran, M.N. Hamidon, Humidity sensors principle, mechanism, and fabrication technologies: a comprehensive review. Sensors 14, 7881–7939 (2014). https://doi.org/10.3390/s14050788110.3390/s140507881 ↗
73. O. Gröning, O.M. Küttel, C. Emmenegger, P. Gröning, L. Schlapbach, Field emission properties of carbon nanotubes. J. Vac. Sci. Technol. B 18, 665–678 (2000)10.1116/1.591258 ↗
74. A.M. Fekry, S.A. Abdel-Gawad, R.H. Tammam, M.A. Zayed, An electrochemical sensor for creatinine based on carbon nanotubes/folic acid /silver nanoparticles modified electrode. Measurement 163, 107958 (2020)10.1016/j.measurement.2020.107958 ↗
75. S.H. Jhi, S.G. Louie, M.L. Cohen, Electronic properties of oxidized carbon nanotubes. Phys. Rev. Lett. 85, 1710 (2000)10.1103/PhysRevLett.85.1710 ↗
76. V. Bogdanovskaya, I. Vernigor, M. Radina, V. Sobolev, V. Andreev, N. Nikolskaya, Modified carbon nanotubes: surface properties and activity in oxygen reduction reaction. Catalysts 80(11), 1354 (2021)10.3390/catal11111354 ↗
77. Y. Huang, X. Si, M. Han, C. Bai, S. Liu, Int. J. Electrochem. Sci. 18(4), 100075 (2023)10.1016/j.ijoes.2023.100075 ↗
78. M.S. Mathew, K. Joseph, Green synthesis of gluten-stabilized fluorescent gold quantum clusters: application as turn-on sensing of human blood creatinine. ACS Sustain. Chem. Eng. 5, 4837–4845 (2017)10.1021/acssuschemeng.7b00273 ↗
79. A. Krishnegowda, N. Padmarajaiah, S. Anantharaman, K. Honnur, Spectrophoto- metric assay of creatinine in human serum sample. Arab. J. Chem. 10, S2018–S2024 (2017)10.1016/j.arabjc.2013.07.030 ↗
80. P.J. Babu, A.M. Raichur, M. Doble, Synthesis and characterization of biocompatible carbon-gold (C-Au) nanocomposites and their biomedical applications as an optical sensor for creatinine detection and cellular imaging. Sens. Actuators B Chem. 258(126), 7–1278 (2018)
81. S. Hooshmand, Z. Es’haghi, Microfabricated disposable nanosensor based on CdSe quantum dot/ionic liquid-mediated hollow fiber-pencil graphite electrode for simultaneous electrochemical quantification of uric acid and creatinine in human samples. Anal. Chim. Acta 972, 28–37 (2017)10.1016/j.aca.2017.04.035 ↗
82. S. Yadav, R. Devi, A. Kumar, C.S. Pundir, Tri-enzyme functionalized ZnONPs/CHIT/c-MW CNT/PANI composite film for amperometric determination of creatinine. Biosens Bioelec- tron. 28(1), 64–70 (2011)10.1016/j.bios.2011.06.044 ↗
83. S. Yadav, R. Devi, P. Bhar, S. Singhla, C.S. Pundir, Immobilization of creatininase, creatinase and sarcosine oxidase on iron oxide nanoparticles/chitosan-g-polyaniline modified Pt electrode for detection of creatinine. Enzyme Microb. Technol. 50(4–5), 247–254 (2012)10.1016/j.enzmictec.2012.01.008 ↗
84. V. Serafín, P. Hernández, L. Agüí, P. Yáñez-Sedeño, J.M. Pingarrón, Electrochemical biosensor for creatinine based on the immobilization of creatininase, creatinase and sarcosine oxidase onto a ferrocene/horseradish peroxidase/gold nanoparticles/multi-walled carbon nanotubes/teflon composite electrode. Electrochim. Acta 97, 175–183 (2013)10.1016/j.electacta.2013.03.005 ↗