journal article·2014-02

Auxetic oesophageal stents: structure and mechanical properties

Murtaza Najabat Ali, James J. C. Busfield, Ihtesham U. Rehman

Publisher page

Abstract

Oesophageal cancer is the ninth leading cause of malignant cancer death and its prognosis remains poor, ranking as the sixth most frequent cause of death in the world. This research work aims to adopt an Auxetic (rotating-squares) geometry device, that had previously been examined theoretically and analysed by Grima and Evans (J Mater Sci Lett 19(17):1563-1565, 2000), to produce a novel Auxetic oesophageal stent and stent-grafts relevant to the palliative treatment of oesophageal cancer and also for the prevention of dysphagia. This paper discusses the manufacture of a small diameter Auxetic oesophageal stent and stent-graft. The oral deployment of such an Auxetic stent would be simplest if a commercial balloon dilatational catheter was used as this obviates the need for an expensive dedicated delivery system. A novel manufacturing route was employed in this research to develop both Auxetic films and Auxetic oesophageal stents, which ranged from conventional subtractive techniques to a new additive manufacturing method. Polyurethane was selected as a material for the fabrication of Auxetic films and Auxetic oesophageal stents because of its good biocompatibility and non-toxicological properties. The Auxetic films were later used for the fabrication of seamed Auxetic oesophageal stents. The flexible polyurethane tubular grafts were also attached to the inner luminal side of the seamless Auxetic oesophageal stents, in order to prevent tumour in-growth. Scanning electron microscopy was used to conduct surface morphology study by using different Auxetic specimens developed from different conventional and new additive manufacturing techniques. Tensile testing of the Auxetic films was performed to characterise their mechanical properties. The stent expansion tests of the Auxetic stents were done to analyse the longitudinal extension and radial expansion of the Auxetic stent at a range of radial pressures applied by the balloon catheter, and to also identify the pressure values where the Auxetic stent fails. Finite element models of both Auxetic film and Auxetic stent were developed, and the results were compared with experimental results with a good agreement. The tensile testing of the Auxetic polyurethane films revealed that the Poisson's ratio of the sample ranged between -0.87 and -0.963 at different uniaxial tensile load values. From the stent expansion test, it was found that the Auxetic oesophageal stent radially expanded from 0.5 to 5.73 mm and longitudinally extended from 0.15 to 1.83 mm at a range of applied pressure increments (0.5-2.7 bar) from the balloon catheter.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Cellular and Composite Structures · Marine and Offshore Engineering Studies · Polymer composites and self-healing

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. McCabe ML, Dlamini Z. The molecular mechanisms of oesophageal cancer. Int Immunopharmacol. 2005;5(7–8):1113–30.10.1016/j.intimp.2004.11.017 ↗
2. Lerut T, Stamenkovic S, Coosemans W. Obsructive cancer of the oesophagus and gastroesophageal junction. Eur J Cancer Suppl. 2005;3(3):177–82.10.1016/S1359-6349(05)80274-5 ↗
3. Lamb PJ, Griffin SM. The anatomy and physiology of the oesophagus. London: Springer; 2006.
4. Natali AN, Carniel EL, Gregersen H. Biomechanical behaviour of oesophageal tissues: material and structural configuration, experimental data and constitutive analysis. Med Eng Phys. 2009;31:1056–62.10.1016/j.medengphy.2009.07.003 ↗
5. Yang W, Fung TC, Chian KS, Chong CK. Three-dimensional finite element model of the two-layered oesophagus, including the effects of residual strains and buckling of mucosa. Proc Inst Mech Eng Part H J Eng Med. 2007;221(H4):417–26.10.1243/09544119JEIM47 ↗
6. Pope CE, Horton PF. Intraluminal force transducer measurements of human esophageal peristalsis. Gut. 1972;13(6):464–70.10.1136/gut.13.6.464 ↗
7. Schoen HJ, Morris DW, Cohen S. Esophageal peristaltic force in man—response to mechanical and pharmacological alterations. Am J Dig Dis. 1977;22(7):589–97.10.1007/BF01073076 ↗
8. Pennathur A, Chang AC, McGrath KM, Steiner G, Alvelo-Rivera M, Awais O, Gooding WE, Christie NA, Gilbert S, Landreneau RJ, Luketich JD. Polyflex expandable stents in the treatment of esophageal disease: initial experience. Ann Thorac Surg. 2008;85(6):1968–73.10.1016/j.athoracsur.2008.01.095 ↗
9. Schoppmann SF, Langer FB, Prager G, Zacheri J. Outcome and complications of long-term self-expanding esophageal stenting. Dis Esophagus. 2013;26(2):154–158.10.1111/j.1442-2050.2012.01337.x ↗
10. Grima JN, Evans KE. Auxetic behavior from rotating squares. J Mater Sci Lett. 2000;19(17):1563–5.10.1023/A:1006781224002 ↗
11. Attard D, Manicaro E, Gatt R, Grima JN. On the properties of Auxetic rotating stretching squares. Physica Status Solidi B [Basic Solid State Physics]. 2009;246(9):2045–54.10.1002/pssb.200982035 ↗
12. Grima JN, Farrugia PS, Caruana C, Gatt R, Attard D. Auxetic behaviour from stretching connected squares. J Mater Sci. 2008;43(17):5962–71.10.1007/s10853-008-2765-0 ↗
13. Ali MN, Rehman IU. An Auxetic structure configured as oesophageal stent with potential to be used for palliative treatment of oesophageal cancer; development and in vitro mechanical analysis. J Mater Sci Mater Med. 2011;22(11):2573–81.10.1007/s10856-011-4436-y ↗
14. Mohan V, Kozarek RA. Placement of conventional and expandable stents for malignant esophageal stenosis. Tech Gastrointest Endosc. 2001;3(3):166–75.10.1053/tgie.2001.24001 ↗
15. Sabzi M, Mirabedini SM, Zohuriaan-Mehr J, Atai M. Surface modification of TiO2 nano-particles with silane coupling agent and investigation of its effect on the properties of polyurethane composite coating. Prog Org Coat. 2009;65:222–8.10.1016/j.porgcoat.2008.11.006 ↗
16. Grima JN, Manicaro E, Attard D. Auxetic behaviour from connected different-sized squares and rectangles. Proc R Soc Math Phys Eng Sci. 2011;467(2126):439–58.10.1098/rspa.2010.0171 ↗