Development of pH sensitive polyacrylamide grafted pectin hydrogel for controlled drug delivery system
Source abstract
Abstract
In the present study an attempt was made to graft polyacrylamide on pectin. The grafted polymer was characterized by FTIR spectroscopy, differential scanning calorimetry and X-ray diffraction. Rheological property of pectin solution was compared with the product solution. The grafted polymer was cross-linked with varying amount of glutaraldehyde. The swelling properties of the cross-linked product were also studied. The salicylic acid, an antipyretic drug, was incorporated in the cross-linked gel as a model drug and the drug release studies were done in a modified Franz's diffusion cell. The effect of cross-linking density on the release property of salicylic acid was studied through the cross-linked product. The product showed better film forming property and gelling property than pectin. The comparative rheological properties of pectin and grafted copolymer indicated change in the property of the product. FTIR studies indicated incorporation of amide group. Differential scanning calorimetry and XRD suggested formation of a new polymer. Swelling study indicated pH dependent swelling of the cross-linked hydrogel. Salicylic acid release indicated pH dependent release from the hydrogel.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Hydrogels: synthesis, properties, applications · Polysaccharides Composition and Applications · Polysaccharides and Plant Cell Walls
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. S. P. VYAS and R. P. KHAR, in “Targeted & Controlled Drug Delivery Novel Carrier Systems” (1st edn. CBS Publishers and distributors, New Delhi, India, 2002) p. 1–5
2. N. A. PEPPAS and A. G. MIKOS, in “Hydrogels in Medicine and Pharmacy—Vol. 1”, Edited by: N. A. PEPPAS (CRC Press, Boca Raton, FL, 1986), pp. 1–27
3. L. BRANNON-PEPPAS, in “Absorbent Polymer Technology”, Edited by: L. BRANNON-PEPPAS and R. S. HARLAND (Elsevier, Amsterdam, 1990), pp. 45–6610.1016/B978-0-444-88654-5.50008-X ↗
4. Y. KIMURA, in “Biomedical Applications of Polymeric Materials”, Edited by: T. TSURUTA et al. (CRC Press, Boca Raton, FL, 1993) pp. 8–9
5. B. D. RATNER and A. S. HOFFMAN, in “Hydrogels for Medical and Related Applications, ACS Symposium Series, No. 31”, Edited by: J. D. ANDRADE (American Chemical Society, Washington, DC, 1976), p. 1–3610.1021/bk-1976-0031.ch001 ↗
6. N. A. PEPPAS, in “Hydrogels in Medicine” (CRS Press, Boca Raton, FL, 1986)
7. N. A. PEPPAS and R. LANGER, Science 263 (1994) 1715–172010.1126/science.8134835 ↗
8. K. PARK, in “Controlled Release: Challenges and Strategies”, (American Chemical Society, Washington, DC, 1997)
9. N. A. PEPPAS, Curr. Opin. Coll. Int. Sci. 2 (1997) 531–53710.1016/S1359-0294(97)80103-3 ↗
10. O. FELT, P. BURI and R. GURNY, Drug Dev. Ind. Pharm. 24 (1998) 979–99310.3109/03639049809089942 ↗
11. L. HOVGAARD and H. BRONDSTED, Crit. Rev. Ther. Drug Carrier Syst. 13 (1996) 185–22310.1615/CritRevTherDrugCarrierSyst.v13.i3-4.10 ↗
12. V. R. SINHA and R. KUMRIA, Int. J. Pharm. 224 (2001) 19–3810.1016/S0378-5173(01)00720-7 ↗
13. S. C. WERCH and A. C. IVY, Am. J. Digest. Dis. 8 (1941) 101–10510.1007/BF02998207 ↗
14. M. ASHFORD and J. T. FELL, J. Drug Target. 2(3) (1994) 241–25710.3109/10611869408996806 ↗
15. J. P. F. BAI and J. H. GUO, Crit. Rev. Ther. Drug Carrier Syst. 12(4) (1995) 339–37110.1615/CritRevTherDrugCarrierSyst.v12.i4.30 ↗
16. F. M. ROMBOUTS and J. F. Thibault, in “Chemistry and Function of Pectins”, Edited by: M. L. FISHMAN and J. J. JEN (Washington, DC: American Chemical Society, ACS Series 310, 1986) p. 49–60
17. J. JOHN MEISTER, in “Principle, Techniques and Application” (Marcel Dekker, Inc., 2000) p. 331
18. G. F. FANTA, in “Synthesis of graft and block copolymers of starch, block and graft copolymerisation—Vol 1”, Edited by: R. J. CERESA (Wiley, New york, 1973) p. 11
19. A. K. JAIN, N. S. THOMAS and R. PANCHAGNULA, J. Control Release 79 (2002) 93–10110.1016/S0168-3659(01)00524-7 ↗
20. R. PANCHAGNULA, K. STEMMER and W. A. RITSCHEL, Exp. Clin. Pharmacol. 19 (1997) 335–391
21. T. W. WONG, H. Y. LEE, L. W. CHAN and P. W. S. HENG, Int J Pharm 242 (2002) 233–23710.1016/S0378-5173(02)00163-1 ↗
22. EN 30993 Standard. Biological evaluation of medical devices * Part 4: selection of tests for interactions with blood, 1993
23. M. B. HANSEN, S. E. NIELSEN and K. BERG, J Immunol Methods, 119 (1989) 203e1010.1016/0022-1759(89)90397-9 ↗
24. T. MOSMANN, J Immunol Methods 65 (1983) 55e6310.1016/0022-1759(83)90303-4 ↗
25. H. N. CHENG, M. TAKAI and E. A. EKONG, Macromol. Symp. 140 (1999) 145–15310.1002/masy.19991400116 ↗
26. D. GO´MEZ-DI´Az and J. M. NAVAZA, J. Food Eng. 56 (2003) 387–39210.1016/S0260-8774(02)00211-X ↗
27. A. ANIS, A. K. BANTHIA, S. MONDAL and A. K. THAKUR, Chin. J. Polym. Sci. 5 (2006) 44910.1142/S0256767906001515 ↗