journal article·2009-08

Mechanical, physical, and chemical characterization of Ti–35Nb–5Zr and Ti–35Nb–10Zr casting alloys

Ana Lúcia Roselino Ribeiro, Rubens Caram Junior, Flávia Farias Cardoso, Romeu Belon Fernandes Filho, Luís Geraldo Vaz

Publisher page

Abstract

Titanium is used due its excellent properties in medical and dentistry areas. With the objective of exploiting better mechanical properties, not altering its biocompatibility, it was intended to add niobium and zirconium to the titanium, being formulated two alloys Ti-35%Nb-5%Zr (alloy 1) and Ti-35%Nb-10%Zr (alloy 2) wt% produced by an arc melting method. The chemical analysis of the samples was accomplished by X-ray fluorescence, and the microstrutural evaluation by scanning electron microscopy and X-ray diffraction. The mechanical tests were: Vickers hardness, tensile strength, mechanical cycling, and fracture analysis. The results allowed characterizing the alloy 1 as alpha + beta type and the alloy 2 as beta type. It is found that the alloy 1 presented larger hardness and smaller tensile strength than the alloy 2. The fractures, after the tensile test, were of the ductile type and, after the mechanical cycling, they were of the mixed type for both alloys.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Intermetallics and Advanced Alloy Properties · MXene and MAX Phase Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Kim HS, Kim WY, Lim SH. Microstructure and elastic modulus of Ti–Nb–Si ternary alloys for biomedical applications. Scr Mater. 2006;54:887–91. doi: 10.1016/j.scriptamat.2005.11.001 .10.1016/j.scriptamat.2005.11.001 ↗
2. Kobayashi E, Doi H, Yoneyama T, Hamanaka H, Gibson IR, Best SM, et al. Influence of aging heat treatment on mechanical properties of biomedical Ti–Zr based ternary alloys containing niobium. J Mater Sci: Mater Med. 1998;9:625–30. doi: 10.1023/A:1008927407556 .
3. Lee CM, Ju CP, Chern Lin JH. Structureûproperty relationship of cast Ti–Nb alloys. J Oral Rehabil. 2002;29:314–22. doi: 10.1046/j.1365-2842.2002.00825.x .10.1046/j.1365-2842.2002.00825.x ↗
4. Niinomi M. Fatigue performance and cyto-toxicity of low rigidity titanium alloy, Ti–29Nb–13Ta–4.6Zr. Biomaterials. 2003;24:2673–83. doi: 10.1016/S0142-9612(03)00069-3 .10.1016/S0142-9612(03)00069-3 ↗
5. Niinomi M. Mechanical biocompatibilities of titanium alloys for biomedical applications. J Mech Behav Biomed Mater. 2008;1:30–42. doi: 10.1016/j.jmbbm.2007.07.001 .10.1016/j.jmbbm.2007.07.001 ↗
6. Pipino F. The bone-prosthesis interaction. J Orthop Traumatol. 2000;1:3–9.10.1007/PL00012193 ↗
7. Puleo DA, Nanci A. Understanding and controlling the boneûimplant interface. Biomaterials. 1999;20:2311–21. doi: 10.1016/S0142-9612(99)00160-X .10.1016/S0142-9612(99)00160-X ↗
8. Niinomi M. Mechanical properties of biomedical titanium alloys. Mater Sci Eng A Struct Mater. 1998;243:231–6. doi: 10.1016/S0921-5093(97)00806-X .10.1016/S0921-5093(97)00806-X ↗
9. Semlitsch M, Staub F, Weber H. Titanium-aluminiumniobium alloy, development for biocompatible, high-strength surgical implants. Biomed Tech (Berl). 1985;30:334–9.10.1515/bmte.1985.30.12.334 ↗
10. Buly RL, Huo MH, Salvati E, Brien W, Bansal M. Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 7l cases. J Arthroplasty. 1992;7:315–23. doi: 10.1016/0883-5403(92)90056-V .10.1016/0883-5403(92)90056-V ↗
11. Rao S, Ushida T, Tateishi T, Okazaki Y, Asao S. Effect of Ti, Al, and V ions on the relative growth rate of fibroblasts (L929) and osteoblasts (MC3T3-E1) cells. Biomed Mater Eng. 1996;6:79–86.
12. Sumner DR, Galante JO. Determinants of stress shielding: design versus materials versus interface. Clin Orthop Relat Res. 1992;274:202–12.10.1097/00003086-199201000-00020 ↗
13. Wang K. The use of titanium for medical applications in the USA. Mater Sci Eng A Struct Mater. 1996;213:134–7. doi: 10.1016/0921-5093(96)10243-4 .10.1016/0921-5093(96)10243-4 ↗
14. Niinomi M. Recent metallic materials for biomedical applications. Metall Trans-A. 2002;33:477–86.10.1007/s11661-002-0109-2 ↗
15. Elias LM, Schneider SG, Schneider S, Silva HM, Malvisi F. Microstructural and mechanical characterization of biomedical Ti–Nb–Zr(–Ta) alloys. Mater Sci Eng A Struct Mater. 2006;432:108–12. doi: 10.1016/j.msea.2006.06.013 .10.1016/j.msea.2006.06.013 ↗
16. Ferrandini PL, Cardoso FF, Souza SA, Afonso CR, Caram R. Aging response of the Ti 35Nb 7Zr 5Ta and Ti 35Nb 7Ta alloys. J Alloy Compd. 2007;433:207–10. doi: 10.1016/j.jallcom.2006.06.094 .10.1016/j.jallcom.2006.06.094 ↗
17. Niinomi M, Hattori T, Morikawa K, Kasuga T, Suzuki A, Fukui H, et al. Development of low rigidity β-type titanium alloy for biomedical applications. Mater Trans. 2002;43:2970–7. doi: 10.2320/matertrans.43.2970 .10.2320/matertrans.43.2970 ↗
18. Schneider S, Schneider SG, Silva HM, Moura Neto C. Study of the non-linear stress–strain behavior in Ti–Nb–Zr alloys. Mater Res. 2005;8:435–8. doi: 10.1590/S1516-14392005000400013 .10.1590/S1516-14392005000400013 ↗
19. Godley R, Starosvetsky D, Gotman I. Corrosion behavior of a low modulus β-Ti–45%Nb alloy for use in medical implants. J Mater Sci: Mater Med. 2006;17:63–7. doi: 10.1007/s10856-006-6330-6 .
20. Oliveira V, Chaves RR, Bertazzoli R, Caram R. Preparation and characterization of Ti–Al–Nb orthopedic implants. Braz J Chem Eng. 1998;15:326–33. doi: 10.1590/S0104-66321998000400002 .10.1590/S0104-66321998000400002 ↗
21. Lavos-Valereto IC, Konig B Jr, Rossa C Jr, Marcantonio E Jr, Zavaglia AC. A study of histological responses from Ti–6Al–7Nb alloy dental implants with and without plasma-sprayed hydroxyapatite coating in dogs. J Mater Sci: Mater Med. 2001;12:273–6. doi: 10.1023/A:1008975418453 .
22. Müller FA, Bottino MC, Müller L, Henriques VAR, Lohbauer U, Bressiani AHA, et al. In vitro apatite formation on chemically treated (P/M) Ti–13Nb–13Zr. Dent Mater. 2008;24:50–6. doi: 10.1016/j.dental.2007.02.005 .10.1016/j.dental.2007.02.005 ↗
23. Okasaki Y, Gotoh E. Comparison of metal release from various metallic biomaterials in vivo. Biomaterials. 2005;26:11–21. doi: 10.1016/j.biomaterials.2004.02.005 .10.1016/j.biomaterials.2004.02.005 ↗
24. Okasaki Y, Gotoh E, Manabe T, Kobayashi K. Comparison of metal concentrations in rat tibia tissues with various metallic implants. Biomaterials. 2004;25:5913–20. doi: 10.1016/j.biomaterials.2004.01.064 .10.1016/j.biomaterials.2004.01.064 ↗
25. ASTM E 606. Standard practice for strain-controlled fatigue testing (West Conshohocken, ASTM, 2005).
26. ASTM E 8M Standard test methods for tension testing of metallic materials [metric] (West Conshohocken, ASTM, 2004).
27. ASM handbook. Fractography (Ohio, ASM International, 1987).
28. Tang X, Ahmed T, Rack HJ. Phase transformations in Ti–Nb–Ta and Ti–Nb–Ta–Zr alloys. J Mater Sci. 2000;35:1805–11. doi: 10.1023/A:1004792922155 .10.1023/A:1004792922155 ↗
29. Dobromyslov AV, Elkin VA. Martensitic transformation and metastable alloys with d-metals of 4–6 periods. Scr Mater. 2001;44:905–10. doi: 10.1016/S1359-6462(00)00694-1 .10.1016/S1359-6462(00)00694-1 ↗
30. Kim JI, Kim HY, Inamura T, Hosoda H, Miyazaki S. Shape memory characteristics of Ti–22Nb–(2–8)Zr(at.%) biomedical alloys. Mater Sci Eng A Struct Mater. 2005;403:334–9. doi: 10.1016/j.msea.2005.05.050 .10.1016/j.msea.2005.05.050 ↗
31. Moffat DL, Larbalestier DC. The competition between the alpha and omega phases in aged Ti–Nb alloys. Metall Trans-A. 1988;19:1687–94.10.1007/BF02645136 ↗
32. Geetha M, Singh AK, Gogia AK, Asokamani R. Effect of thermomechanical processing on evolution of various phases in Ti–Nb–Zr thermomechanical processing on evolution of various phases in Ti–Nb–Zr. J Alloy Compd. 2004;384:131–44. doi: 10.1016/j.jallcom.2004.04.113 .10.1016/j.jallcom.2004.04.113 ↗
33. ASM handbook. Materials Characterization (Ohio, ASM International, 1986).
34. Lin CW, Ju CP, Lin JHC. A comparison of the fatigue behavior of cast Ti–7.5Mo with c.p. titanium, Ti–6Al–4V and Ti–13Nb–13Zr alloys. Biomaterials. 2005;26:2899–907. doi: 10.1016/j.biomaterials.2004.09.007 .10.1016/j.biomaterials.2004.09.007 ↗
35. Brooks CR, Choushury A. Metallurgical failure analysis. New York: McGraw-Hill; 1993.