Pre-clinical studies to validate the MITCH PCR™ Cup: a flexible and anatomically shaped acetabular component with novel bearing characteristics
Source abstract
Abstract
A previous clinical study was undertaken to evaluate the safety and efficacy of an anatomically shaped, flexible acetabular cup. Clinical results achieved were satisfactory, although some deficiencies in the model were identified. Design changes to the original model have been implemented to improve both initial stability and long term biological fixation. This was achieved through modifications made to both the anchoring mechanism and by the application of an appropriate backing surface layer promoting bone on-growth. In addition, changes to the articulation couple have also been introduced to improve implant durability and bearing performance, utilising a carbon fibre reinforced polyetheretherketone--alumina couple. Simulated loading, in both models, was performed using Finite Element Analysis. Mechanical and tribological tests were also performed to ensure the robustness of the new optimised design. Bio-compatibility of the articulation couple was demonstrated using an animal model. Implantation of the device has been extensively tested and re-validated in vitro to achieve a favourable polar contact between cup and femoral head and establish a reproducible operative technique. This preliminary work is undertaken prior to commencing a post market surveillance study of the CE marked implant.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Hip disorders and treatments · Total Knee Arthroplasty Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (19)
Show source-provided references
1. E. MORSCHER, B. BERLI, W. JOCKERS and R. SCHENK, Clin. Orthop. 341 (1997) 4210.1097/00003086-199708000-00008 ↗
2. J. P. MAUMY, Hip Int. 11 (2001) 4210.1177/112070000101100105 ↗
3. W. PLOTZ, R. GRADINGER, H. RECHL, R. ASCHERL, S. WICKE-WITTENIUS and E. HIPP, Arch. Orthop. Trauma Surg. 111(2) (1992) 10210.1007/BF00443476 ↗
4. R. E. FIELD and N. RUSHTON, J. Bone Joint Surg. Br. 87-B (2005) 134410.1302/0301-620X.87B10.16559 ↗
5. R. E. FIELD, M. D. CRONIN, P. J. SINGH, C. BURTENSHAW and N. RUSHTON, Acta Orthopaed. 77(5) (2006) 72610.1080/17453670610012908 ↗
6. A. SOOD, R. A. BROOKS, E. JONES, D. J. MATTHEWS, R. E. FIELD and N. RUSHTON, Acta Orthopaed.—Submitted (2006)
7. N. PACE, S. SPURIO and G. RIZZATO, Hip Int. 14(2) (2004) 132
8. M. DALSTRA, R. HUISKES, and L. van ERNING, J. Biomech. Eng. 117 (1995) 27210.1115/1.2794181 ↗
9. H. OONISHI, H. ISHA, and T. HASEGAWA, J. Biomech. 46 (1983) 42710.1016/0021-9290(83)90075-1 ↗
10. M. DALSTRA, R. HUISKES, A. ODGAARD and L. van ERNING, J. Biomech. 26 (1993) 52310.1016/0021-9290(93)90014-6 ↗
11. E. F. MORGAN, H. H. BAYRAKTAR and T. M. KEAVENY, J. Biomech. 36 (2003) 89710.1016/S0021-9290(03)00071-X ↗
12. D. R. PEDERSEN, R. A. BRAND and D. T. DAVY, J. Biomech. 30(9) (1997) 95910.1016/S0021-9290(97)00041-9 ↗
13. D. R. PEDERSEN, R. A. BRAND and D. T. DAVY, Pelvis muscle and acetabular contact forces during gait. 1997. http://www1.elsevier.com/homepage/sab/biomecha/959index.htm (Access date 09/01/07)10.1016/S0021-9290(97)00041-9 ↗
14. S. L. SMITH, and A. UNSWORTH, Proc. Instn. Mech. Engrs 215 Part H (2001) 6110.1243/0954411011533535 ↗
15. A. UNSWORTH, M. J. PEARCY, E. F. T. WHITE and G. WHITE, Eng. Med. 17 (1988) 10110.1243/EMED_JOUR_1988_017_029_02 ↗
16. Stryker Orthopaedics Inc. Technical Data 2005. http://www.victrex.com/en/tech_data/literature.php (Access date 09/01/07)
17. Victrex 150CA30, 30% Carbon Fiber Reinforced. Details of mechanical properties of the composite as supplied by Victrex. http://www.matweb.com (Access date 05/01/07)
18. O. MURATOGLU, C. BRAGDON, D. O’CONNOR, M. JASTY, W. HARRIS, J. Arthroplasty 16(2) (2001) 14910.1054/arth.2001.20540 ↗
19. C. DELAUNAY, F. BONNOMET, J. NORTH, D. JOBARD, C. CAZEAU, J. F. KEMPF, J. Arthroplasty. 16(1) (2001) 4710.1054/arth.2001.17940 ↗