journal article·2019-07

Antimicrobial efficacy of copper-doped titanium surfaces for dental implants

Monika Astasov-Frauenhoffer, Sally Koegel, Tuomas Waltimo, Andrea Zimmermann, Cyril Walker, Irmgard Hauser-Gerspach, Christiane Jung

Publisher page

Abstract

The aim of this in vitro study was to quantify the antibacterial effect of a copper-deposited titanium surface as a model for dental implants on the peri-implantitis-associated strain Porphyromonas gingivalis (DSM 20709). A spark-assisted anodization method in a combined deposition-anodization process was applied to deposit copper on discs made of titanium. This method allows the deposition of different concentrations of copper on the surface by varying the process time. Conventional culturing was used to investigate the adhesion of P. gingivalis onto the discs over 2, 4, and 6 h as well as to study the antibacterial effect of copper released in solution. The viability of the bacterial cells is strongly inhibited on copper-deposited discs and reaches a CFU reduction of 3 log-units after 6 h in comparison to the reference. The copper released in solution causes a reduction of 4 log-units after a 6 h incubation time. With a 6 h incubation time, the CFU count decreases with increasing copper concentrations on the disc (by 2% for the 1.3 µg/disc; 32% for the 5.6 µg/disc; and 34% for the 9.5 µg/disc). However, at a higher copper concentration of 17.7 µg/disc, after 6 h, the decrease in the CFU count is less pronounced than that observed in solution, where a further decrease is observed. In conclusion, copper-functionalized titanium significantly reduces the survival of adhered bacteria and decreases the viable bacterial count in the environment surrounding the titanium. Thus, the area surrounding implants is being protected by copper released from the surface, forming a "safe zone" for improved implant healing.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (43)

Show source-provided references
1. Mombelli A, Müller N, Cionca N. The epidemiology of peri-implantitis. Clin Oral Implants Res. 2012;23:67–76.10.1111/j.1600-0501.2012.02541.x ↗
2. Smeets R, Henningsen A, Jung O, Heiland M, Hammächer C, Stein JM. Definition, etiology, prevention and treatment of peri-implantitis—a review. Head Face Med. 2014;10:34.10.1186/1746-160X-10-34 ↗
3. Pye AD, Lockhart DEA, Dawson MP, Murray CA, Smith AJ. A review of dental implants and infection. J Hosp Infect. 2009;72:104–10.10.1016/j.jhin.2009.02.010 ↗
4. Adil M, Singh K, Verma PK, Khan AU. Eugenol-induced suppression of biofilm-forming genes in Streptococcus mutans: An approach to inhibit biofilms. J Glob Antimicrob Resist. 2014;2:286–92.10.1016/j.jgar.2014.05.006 ↗
5. Darragh L, Robb A, Hardie CM, McDonald S, Valand P, O’Doboghue JM. Reducing implant loss rates in immediate breast reconstructions. Breast. 2017;31:208–13.10.1016/j.breast.2016.11.015 ↗
6. Wang Z, Shen Y, Haapasalo M. Dental materials with antibiofilm properties. Dent Mater. 2014;30:e1–16.10.1016/j.dental.2013.12.001 ↗
7. Swartjes JJ, Sharma PK, van Kooten TG, van der Mei HC, Mahmoudi M, Busscher HJ, Rochford ET. Current developments in antimicrobial surface coatings for biomedical applications. Curr Med Chem. 2015;22:2116–29.10.2174/0929867321666140916121355 ↗
8. Jung C, Straumann L, Kessler A, Pieles U, de Wild M. Antibacterial copper deposited onto and into the oxide layer of titanium implants. BioNanoMat. 2014;15(S1):S180.
9. Kessler A, Straumann L, Pieles U, de Wild M, Jung C. Release kinetics of electrochemically deposited antibacterial copper from anodized titanium implant surfaces. Eur Cell Mater. 2014;27(Suppl 2):24.
10. Knetch MLW, Koole LH. New strategies in the development of antimicrobial coatings: the example of increasing usage of silver and silver nanoparticles. Polymers. 2011;3:340–66.10.3390/polym3010340 ↗
11. Petrini P, Arciola CR, Pezzali I, Bozzini S, Montanaro L, Tanzi MC, Speziale P, Visai L. Antibacterial activity of zinc modified titanium oxide surface. Int J Artif Organs. 2006;29:434–42.10.1177/039139880602900414 ↗
12. Polak M, Ohl A, Quaas M, Lukowski G, Lüthen F, Weltmann KD. Oxygen and water plasma-immersion ion implantation of copper into titanium for antibacterial surfaces of medical implants. Adv Eng Mater. 2010;12:B511–8.10.1002/adem.200980048 ↗
13. Zhang X, Li J, Wang X, Wang Y, Hang R, Huang X, Tang B, Chu PK. Effects of copper nanoparticles in porous TiO2 coatings on bacterial resistance and cytocompatibility of osteoblasts and endothelial cells. Mater Sci Eng C Mater Biol Appl. 2018;82:110–20.10.1016/j.msec.2017.08.061 ↗
14. Tan XW, Goh TW, Saraswathi P, Nyein CL, Setiawan M, Riau A, Lakshminarayanan R, Liu S, Tan D, Beuerman RW, Mehta JS. Effectiveness of antimicrobial peptide immobilization for preventing perioperative cornea implant-associated bacterial infection. Antimicrob Agents Chemother. 2014;58:5229–38.10.1128/AAC.02859-14 ↗
15. Hickok NJ, Shapiro IM, Chen AF. The impact of incorporating antimicrobials into implant surfaces. J Dent Res. 2018;97:14–22.10.1177/0022034517731768 ↗
16. Lemire JA, Harrison JJ, Turner RJ. Antimicrobial activity of metals: mechanisms, molecular targets and applications. Nat Rev Microbiol. 2013;11:371–84.10.1038/nrmicro3028 ↗
17. Chopra I. The increasing use of silver-based products as antimicrobial agents: a useful development or a cause for concern? J Antimicrob Chemother. 2007;59:587–90.10.1093/jac/dkm006 ↗
18. Finley PJ, Norton R, Austin C, Michell A, Zank S, Durham P. Unprecedented silver resistance in clinically isolated Enterobacteriaceae: major implications for burn and wound management. Antimicrob Agents Chemother. 2015;59:4734–41.10.1128/AAC.00026-15 ↗
19. Espírito Santo C, Lam EW, Elowsky CG, Quaranta D, Domaille DW, Chang CJ, Grass G. Bacterial killing by dry metallic copper surfaces. Appl Environ Microbiol. 2011;77:794–802.10.1128/AEM.01599-10 ↗
20. Wan YZ, Raman S, He F, Huang Y. Surface modification of medical metals by ion implantation of silver and copper. Vacuum. 2007;81:1114–8.10.1016/j.vacuum.2006.12.011 ↗
21. Grass G, Rensing C, Solioz M. Metallic copper as an antimicrobial surface. Appl Environ Microbiol. 2011;77:1541–7.10.1128/AEM.02766-10 ↗
22. Lewallen EA, Riester SM, Bonin CA, Kremers HM, Dudakovic A, Kakar S, Cohen RC, Westendorf JJ, Lewallen DG, van Wijnen AJ. Biological strategies for improved osseointegration and osteoinduction of porous metal orthopedic implants. Tissue Eng Part B Rev. 2015;21:218–30.10.1089/ten.teb.2014.0333 ↗
23. Jung C. Surface properties of titanium implants treated by spark-assisted anodizing. Eur Cell Mater. 2010;19(Suppl 2):4.
24. Jung C, Ryter N, Köser J, Hoffmann W, Straumann L, Balimann N, Meier F, de Wild M, Schlottig F, Martin I, Pieles U. Antibacterial functionalization of the surface of titanium implants by electrochemical copper deposition. Eur Cell Mater. 2012;23(Suppl 1):16.
25. Cho SB, Nakanishi K, Soga N, Ohtsuki C, Nakamura T, Kitsugi T, Yamamuro T. Defence of apatite formation on silica gel on its structure: effect of heat treatment. J Am Ceram Soc. 1995;78:1769–74.10.1111/j.1151-2916.1995.tb08887.x ↗
26. Jung C, Mathes S, Bono E, Walker C, Kessler A, Straumann L, de Wild M, de Haller EB. Cell viability on titanium implant surfaces modified with antibacterial copper. Eur Cells Mater. 2015;29(Suppl 2):24.
27. Miller WD. The microorganisms of the human mouth. S.S. White Dental Manufacturing Company 1890. Switzerland: Karger; 1973. Reprinted Basel.
28. Berry CW, Moore TJ, Safar JA, Henry CA, Wagner MJ. Antibacterial activity of dental implant metals. Implant Dent. 1992;1:59–65.10.1097/00008505-199200110-00006 ↗
29. Zhao L, Chu PK, Zhang Y, Wu Z. Antibacterial coatings on titanium implants. J Biomed Mater Res B Appl Biomater. 2009;91:470–80.10.1002/jbm.b.31463 ↗
30. Duguid R. Copper-inhibition of the growth of oral streptococci and actinomycees. Biomaterials. 1983;4:225–7.10.1016/0142-9612(83)90017-0 ↗
31. Mulligan AM, Wilson M, Knowles JC. The effect of increasing copper content in phosphate-based glasses on biofilms of Streptococcus sanguis. Biomaterials. 2003;24:1797–807.10.1016/S0142-9612(02)00577-X ↗
32. Li M, Ma Z, Zhu Y, Xia H, Yao M, Chu X, Wang X, Yang K, Yang M, Zhang Y, Mao C. Towards a molecular understanding of the antibacterial mechanism of copper-bearing titanium alloys against Staphylococcus aureus. Adv Healthc Mater. 2016;5:557–66.10.1002/adhm.201500712 ↗
33. Sun C, Li Y, Li Z, Su Q, Wang Y, Liu X. Durable and washable antibacterial copper nanoparticles bridged by surface grafting polymer brushes on cotton and polymeric materials. J Nanomater. 2018;2018:1–7.
34. Bai B, Zhang E, Liu J, Zhu J. The anti-bacterial activity of titanium-copper sintered alloy against Porphyromonas gingivalis in vitro. Dent Mater J. 2016;35:659–67.10.4012/dmj.2016-001 ↗
35. Dunleavy CS, Golosnoy IO, Curran JA, Clyne TW. Characterisation of discharge events during plasma electrolytic oxidation. Surf Coat Technol. 2009;203:3410–9.10.1016/j.surfcoat.2009.05.004 ↗
36. Jung C, de Wild M. Modifying titanium implant surfaces with antibacterial copper: is this feasible? Eur Cell Mater. 2015. cCM Meet Abstr Collect 2015; eCM XVI:54.
37. Jung C. Characterizing copper incorporated into the oxide layer of anodized titanium. Eur Cell Mater. 2016. eCM Meet Abstr Collect 2016;6:49.
38. Liu R, Memarzadeh K, Chang B, Zhang Y, Ma Z, Allaker RP, Ren L, Yang K. Antibacterial effect of copper bearing titanium alloy (Ti–Cu) against Streptococcus mutans and Porphyromonas gingivalis. Sci Rep. 2016;6:29985.10.1038/srep29985 ↗
39. Astasov-Frauenhoffer A, Zimmermann A, Waltimo T, Hauser-Gerspach I, Jung C. Antibacterial effect of copper functionalized titanium implants on oral bacteria. Eur Cell Mater. 2017. eCM Meet Abstr Collect 2017;3(SSB±RM):29.
40. Mamo W. Physical and biochemical surface properties of gram-positive bacteria in relation to adhesion to bovine mammary cells and tissues. Rev Sci Tech Int Off Epizoot. 1989;8:163–76.10.20506/rst.8.1.402 ↗
41. Katsikogianni M, Missirlis YF. Concise review of mechanisms of bacterial adhesion to biomaterials and of techniques used in estimating bacterial-material interaction. Eur Cell Mater. 2004;8:37–57.10.22203/eCM.v008a05 ↗
42. Dekhtyar Yu, Selutina M, Jung C. Alteration of electrostatic potential of the titanium implant surface by antibacterial copper deposits. Eur Cell Mater. 2016;32(Suppl 1):22.
43. Gottenbos B, Grijpma DW, van der Mei HC, Feijen J, Busscher HJ. Antimicrobial effects of positively charged surfaces on adhering gram-positive and gram-negative bacteria. J Antimicrob Chemother. 2001;48:7–13.10.1093/jac/48.1.7 ↗