journal article·2015-10

Heat transfer properties and thermal cure of glass-ionomer dental cements

Lidia Gavic, Kristina Gorseta, Domagoj Glavina, Beata Czarnecka, John W. Nicholson

Publisher page

Abstract

Under clinical conditions, conventional glass-ionomer dental cements can be cured by application of heat from dental cure lamps, which causes acceleration in the setting. In order for this to be successful, such heat must be able to spread sufficiently through the cement to enhance cure, but not transmit heat so effectively that the underlying dental pulp of the tooth is damaged. The current study was aimed at measuring heat transfer properties of modern restorative glass-ionomers to determine the extent to which they meet these twin requirements. Three commercial glass ionomer cements (Ionofil Molar, Ketac Molar and Equia™ Fill) were used in association with three different light emitting diode cure lamps designed for clinical use. In addition, for each cement, one set of specimens was allowed to cure without application of a lamp. Temperature changes were measured at three different depths (2, 3 and 4 mm) after cure times of 20, 40 and 60 s. The difference among the tested groups was evaluated by ANOVA (P < 0.05) and post hoc Newman-Keuls test. All brands of glass-ionomer showed a small inherent setting exotherm in the absence of heat irradiation, but much greater temperature increases when exposed to the cure lamp. However, temperature rises did not exceed 12.9 °C. Application of the cure lamp led to the establishment of a temperature gradient throughout each specimen. Differences were typically significant (P < 0.05) and did not reflect the nominal power of the lamps, because those lamps have variable cooling systems, and are designed to optimize light output, not heating effect. Because the thermal conductivity of glass-ionomers is low, temperature rises at 4 mm depths were much lower than at 2 mm. At no time did the temperature rise sufficiently to cause concern about potential damage to the pulp.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Mount GJ. Color atlas of glass-ionomer cement. 3rd ed. London: Dunitz; 2002.
2. Nicholson JW. Chemistry of glass-ionomer cements: a review. Biomaterials. 1998;19:485–94.10.1016/S0142-9612(97)00128-2 ↗
3. Wasson EA, Nicholson JW. New aspects of the setting of glass-ionomer cements. J Dent Res. 1993;72:481–3.10.1177/00220345930720020201 ↗
4. Earl MAS, Mount GJ, Hume WR. The effect of varnishes and other surface treatments on water movement across the glass-ionomer cement surface. Aust Dent J. 1989;39:326–9.10.1111/j.1834-7819.1989.tb04641.x ↗
5. Kleverlaan C, van Duinen R, Feilzer A. Mechanical properties of glass ionomer cements affected by curing methods. Dent Mater. 2004;20:45–50.10.1016/S0109-5641(03)00067-8 ↗
6. Guegliema CA, Mohana A, Hesse D, Lenzi TL, Bonini GC, Raggio DP. Influence of ultrasound or halogen light on microleakage and hardness of enamel adjacent to glass ionomer cement. Int J Paediatr Dent. 2012;22:110–5.
7. Gorseta K, Glavina D, Skrinjaric I. Influence of ultrasonic excitation and heat application on the microleakage of glass ionomer cements. Aust Dent J. 2012;57:453–7.10.1111/j.1834-7819.2012.01724.x ↗
8. Gorseta K, Skrinjaric T, Glavina D. The effect of heating and ultrasound on the shear bond strenght of glass ionomer cements. Coll Antropol. 2012;4:1307–12.
9. O’Brien T, Shoja-Assadi F, Lea SC, Burke FJ, Palin WM. Extrinsic energy sources affect hardness through depth during set of a glass-ionomer cement. J Dent. 2010;38:490–5.10.1016/j.jdent.2010.03.004 ↗
10. Nicholson JW, Czarnecka B. Kinetic studies of the effect of varnish on water loss by glass–ionomer cements. Dent Mater. 2007;23:1549–52.10.1016/j.dental.2007.02.004 ↗
11. Inoue T, Saitoh M, Nishiyama M. Thermal properties of glass ionomer cement. J Nihon Univ Sch Dent. 1993;35:252–7.10.2334/josnusd1959.35.252 ↗
12. Watts DC, Smith R. Thermal diffusivity in finite cylindrical specimens of dental cement. J Dent Res. 1981;60:1972–6.10.1177/00220345810600120801 ↗
13. Watts DC, Smith R. Thermal diffusivity in some polyelectrolyte dental cements: the effect of powder/liquid ratio. J Oral Rehabil. 1984;11:285–8.10.1111/j.1365-2842.1984.tb00578.x ↗
14. Tay WM, Braden M. Thermal diffusivity of glass-ionomer cements. J Dent Res. 1987;66:1040–3.10.1177/00220345870660051001 ↗
15. Fukase Y, Saitoh M, Kaketani M, Nishiyama M. Thermal coefficients of paste-paste type pulp capping cements and dentin by xenon flash method. Dent Mater J. 1992;11:189–96.10.4012/dmj.11.189 ↗
16. Algera TJ, Kleverlaan CJ, de Gee AJ, Prahl-Andersen B, Feilzer AJ. The influence of accelerating the setting rate by ultrasound or heat on the bond strenght of glass ionomers used as orthodontic bracket cements. Eur J Orthod. 2005;27:472–6.10.1093/ejo/cji041 ↗
17. Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol. 1965;19:515–30.10.1016/0030-4220(65)90015-0 ↗
18. Khalil SK, Atkins ED. Investigation of glass-ionomer cements using differential scanning calorimetry. J Mater Sci. 1998;9:529–33.
19. Wilson AD, Nicholson JW. Acid-base cements. Cambridge: The University Press; 1994.
20. Wahabi MA, Aalam FA, Fatinv FI, Radwan SA, Eshan IY, Al-Samadani KH. Characteristization of heat emission of light-curing units. Saudi Dent J. 2012;24:91–8.10.1016/j.sdentj.2012.01.003 ↗
21. Yazici AR, Muftu A, Kugel G. Temperature rise produced by different light-curing units through dentin. J Contemp Dent Pract. 2007;8:1–6.
22. Wanderwalle KS, Roberts HW, Tiba A, Charlton DG. Thermal emission and curing efficiency of LED and halogen curing light. Oper Dent. 2005;30:257–64.
23. Brantley WA, Kerby RE. Thermal diffusivity of glass ionomer cement systems. J Oral Rehabil. 1993;20:61–8.10.1111/j.1365-2842.1993.tb01515.x ↗