journal article·2008-02

Effect of molding pressure on fabrication of low-crystalline calcite block

Xin Lin, Shigeki Matsuya, Masaharu Nakagawa, Yoshihiro Terada, Kunio Ishikawa

Publisher page

Abstract

We have reported that low-crystalline porous calcite block, which is useful as a bone substitute or a source material to prepare apatite-type bone fillers could be fabricated by exposing calcium hydroxide compact to carbon dioxide gas saturated with water vapor. In the present study, we investigated the effect of molding pressure on the transformation of calcium hydroxide into calcite and the mechanical strength of the carbonated compact. Transformation into calcite was almost completed within 72 h, however, a small amount of Ca(OH)(2) still remained unreacted at higher molding pressure because of incomplete penetration of CO(2) gas into the interparticle space due to dense packing of Ca(OH)(2) particles. On the other hand, high molding pressure resulted in an increase in diametral tensile strength (DTS) of the calcite compact formed. Critical porosity of the calcite block was calculated as approximately 68%.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Calcium Carbonate Crystallization and Inhibition · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. F. SOUYRIS, C. PELLEQUER, C. PAYROT and C. SERVERA, J. Maxillofac. Surg. 13(2) (1985) 6410.1016/S0301-0503(85)80018-7 ↗
2. G. GUILLEMIN, J. L. PATAT, J. FOURNIE and M. CHETAIL, J. Biomed. Mater. Res. 21(5) (1987) 55710.1002/jbm.820210503 ↗
3. J. L. PATAT and G. GUILLEMIN, Annal Chirurg Plast Esthet 34(3) (1989) 221
4. F. X. ROUX, D. BRASNU, B. LOTY, B. GEORGE and G. GUILLEMIN, J. Neurosurg. 69(4) (1988) 51010.3171/jns.1988.69.4.0510 ↗
5. F. X. ROUX, B. LOTY, D. BRASNU and G. GUILLEMIN, Neuro-Chirurgie 34(2) (1988) 110
6. D. M. ROY and S. K. LINNEHAN, Nature 247 (1974) 22010.1038/247220a0 ↗
7. M. SIVAKUMAR, T. S. KUMAR, K. L. SHANTHA and K. P. RAO, Biomaterials 17 (1996) 170910.1016/0142-9612(96)87651-4 ↗
8. W. SUCHANEK and M. YOSHIMURA, J. Mater. Res. 13 (1998) 9410.1557/JMR.1998.0015 ↗
9. J. C. FRICAIN, R. BAREILLE, F. ULYSSE, B. DUPUY and J. AMDEE, J. Biomed. Mater. Res. 42 (1998) 9610.1002/(SICI)1097-4636(199810)42:1<96::AID-JBM12>3.0.CO;2-M ↗
10. S. MATSUYA, X. LIN, K. UDOH, M. NAKAGAWA, R. SHIMOGORYO, Y. TERADA and K. ISHIKAWA, J. Mater. Sci.: Mater. Med. (2006) in press
11. L. N. PLUMMER and E. BUSENBERG, Geochim Cosmochim Acta 46 (1982) 101110.1016/0016-7037(82)90056-4 ↗
12. K. K. SCHILLER, in “Mechanical properties of non metallic brittle solids”, edited by W. H. Walton (Butterworth, London, 1958) p. 35
13. K. K. SHIHILLER, Br. J. Appl. Phys. 11 (1960) 33810.1088/0508-3443/11/8/307 ↗
14. T. MORI and M. YAMANE, Aust. Dent. J. 27(1) (1982) 3010.1111/j.1834-7819.1982.tb04026.x ↗
15. K. ISHIKAWA and K. ASAOKA, J. Biomed. Mater. Res. 29(12) (1995) 153710.1002/jbm.820291210 ↗
16. Y. LEE, Y. M. HAHM, S. MATSUYA, M. NAKAGAWA and K. ISHIKAWA, J. Mater. Sci. (2006) in press