Bone bonding ability of a chemically and thermally treated low elastic modulus Ti alloy: gum metal
Source abstract
Abstract
The gum metal with composition Ti-36Nb-2Ta-3Zr-0.3O, is free from cytotoxic elements and exhibits a low elastic modulus as well as high mechanical strength. We have previously demonstrated that this gum metal, once subjected to a series of surface treatments--immersion in 1 M NaOH (alkali treatment) and then 100 mM CaCl2, before heating at 700 °C (sample: ACaH-GM), with an optional final hot water immersion (sample: ACaHW-GM)--has apatite-forming ability in simulated body fluid. To confirm the in vivo bioactivity of these treated alloys, failure loads between implants and bone at 4, 8, 16, and 26 weeks after implantation in rabbits' tibiae were measured for untreated gum metal (UT-GM), ACaH-GM and ACaHW-GM, as well as pure titanium plates after alkali and heat treatment (AH-Ti). The ACaH-GM and UT-GM plates showed almost no bonding, whereas ACaHW-GM and AH-Ti plates showed successful bonding by 4 weeks, and their failure loads subsequently increased with time. The histological findings showed a large amount of new bone in contact with the surface of ACaHW-GM and AH-Ti plates, suggesting that the ACaHW treatment could impart bone-bonding bioactivity to a gum metal in vivo. Thus, with this improved bioactive treatment, these advantageous gum metals become useful candidates for orthopedic and dental devices.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (22)
Show source-provided references
1. Niinomi M, Hattori T, Morikawa K, Kasuga T, Suzuki A, Fukui H, et al. Development of low rigidity β-type titanium alloy for biomedical applications. Mater Trans. 2002;43(12):2970–7.10.2320/matertrans.43.2970 ↗
2. Head WC, Bauk DJ, Emerson RH Jr. Titanium as the material of choice for cementless femoral components in total hip arthroplasty. Clin Orthop Relat Res. 1995;311:85–90.
3. Long M, Rack HJ. Titanium alloys in total joint replacement–a materials science perspective. Biomaterials. 1998;19(18):1621–39.10.1016/S0142-9612(97)00146-4 ↗
4. Mont MA, Hungerford DS. Proximally coated ingrowth prostheses. A review. Clin Orthop Relat Res. 1997;344:139–49.
5. Nourbash PS, Paprosky WG. Cementless femoral design concerns. Rationale for extensive porous coating. Clin Orthop Relat Res. 1998;355:189–99.10.1097/00003086-199810000-00020 ↗
6. Glassman AH, Bobyn JD, Tanzer M. New femoral designs: do they influence stress shielding? Clin Orthop Relat Res. 2006;453:64–74.10.1097/01.blo.0000246541.41951.20 ↗
7. Andrew TA, Flanagan JP, Gerundini M, Bombelli R. The isoelastic, noncemented total hip arthroplasty. Preliminary experience with 400 cases. Clin Orthop Relat Res. 1986;206:127–38.10.1097/00003086-198605000-00025 ↗
8. Butel J, Robb JE. The isoelastic hip prosthesis followed for 5 years. Acta Orthop Scand. 1988;59(3):258–62.10.3109/17453678809149357 ↗
9. Niinimaki T, Jalovaara P. Bone loss from the proximal femur after arthroplasty with an isoelastic femoral stem. BMD measurements in 25 patients after 9 years. Acta Orthop Scand. 1995;66(4):347–51.10.3109/17453679508995559 ↗
10. Saito T, Furuta T, Hwang JH, Kuramoto S, Nishino K, Suzuki N, et al. Multifunctional alloys obtained via a dislocation-free plastic deformation mechanism. Science. 2003;300(5618):464–7. doi: 10.1126/science.1081957 .10.1126/science.1081957 ↗
11. Yamaguchi S, Kizuki T, Takadama H, Matsushita T, Nakamura T, Kokubo T. Formation of a bioactive calcium titanate layer on gum metal by chemical treatment. J Mater Sci - Mater Med. 2012;23(4):873–83. doi: 10.1007/s10856-012-4569-7 .10.1007/s10856-012-4569-7 ↗
12. Nishiguchi S, Kato H, Fujita H, Kim HM, Miyaji F, Kokubo T, et al. Enhancement of bone-bonding strengths of titanium alloy implants by alkali and heat treatments. J Biomed Mater Res. 1999;48(5):689–96.10.1002/(SICI)1097-4636(1999)48:5<689::AID-JBM13>3.0.CO;2-C ↗
13. Kim HM, Miyaji F, Kokubo T, Nakamura T. Preparation of bioactive Ti and its alloys via simple chemical surface treatment. J Biomed Mater Res. 1996;32(3):409–17. doi: 10.1002/(SICI)1097-4636(199611)32:3<409:AID-JBM14>3.0.CO;2-B .10.1002/(SICI)1097-4636(199611)32:3<409::AID-JBM14>3.0.CO;2-B ↗
14. Fukuda A, Takemoto M, Saito T, Fujibayashi S, Neo M, Yamaguchi S, et al. Bone bonding bioactivity of Ti metal and Ti-Zr-Nb-Ta alloys with Ca ions incorporated on their surfaces by simple chemical and heat treatments. Acta Biomater. 2011;7(3):1379–86. doi: 10.1016/j.actbio.2010.09.026 .10.1016/j.actbio.2010.09.026 ↗
15. Niinomi M. Recent metallic materials for biomedical applications. Metall and Mat Trans A. 2002;33(3):477–86. doi: 10.1007/s11661-002-0109-2 .10.1007/s11661-002-0109-2 ↗
16. Kim HM, Miyaji F, Kokubo T, Nakamura T. Effect of heat treatment on apatite-forming ability of Ti metal induced by alkali treatment. J Mater Sci - Mater Med. 1997;8(6):341–7.10.1023/A:1018524731409 ↗
17. Nishiguchi S, Nakamura T, Kobayashi M, Kim HM, Miyaji F, Kokubo T. The effect of heat treatment on bone-bonding ability of alkali-treated titanium. Biomaterials. 1999;20(5):491–500.10.1016/S0142-9612(98)90203-4 ↗
18. Fujibayashi S, Nakamura T, Nishiguchi S, Tamura J, Uchida M, Kim HM, et al. Bioactive titanium: effect of sodium removal on the bone-bonding ability of bioactive titanium prepared by alkali and heat treatment. J Biomed Mater Res. 2001;56(4):562–70.10.1002/1097-4636(20010915)56:4<562::AID-JBM1128>3.0.CO;2-M ↗
19. Nakamura T, Yamamuro T, Higashi S, Kokubo T, Itoo S. A new glass–ceramic for bone replacement: evaluation of its bonding to bone tissue. J Biomed Mater Res. 1985;19(6):685–98. doi: 10.1002/jbm.820190608 .10.1002/jbm.820190608 ↗
20. Yamaguchi S, Takadama H, Matsushita T, Nakamura T, Kokubo T. Apatite-forming ability of Ti–15Zr–4Nb–4Ta alloy induced by calcium solution treatment. J Mater Sci - Mater Med. 2010;21(2):439–44. doi: 10.1007/s10856-009-3904-0 .10.1007/s10856-009-3904-0 ↗
21. Sakai R, Itoman M, Mabuchi K. Assessments of different kinds of stems by experiments and FEM analysis: appropriate stress distribution on a hip prosthesis. Clin. Biomech. (Bristol, Avon). 2006;21(8):826–33. doi: 10.1016/j.clinbiomech.2006.03.008 .10.1016/j.clinbiomech.2006.03.008 ↗
22. Caouette C, Yahia L, Bureau MN. Reduced stress shielding with limited micromotions using a carbon fibre composite biomimetic hip stem: a finite element model. Proc Inst Mech Eng [H]. 2011;225(9):907–19. doi: 10.1177/0954411911412465 .10.1177/0954411911412465 ↗