A 24-month evaluation of a percutaneous osseointegrated limb-skin interface in an ovine amputation model
Source abstract
Abstract
Percutaneous osseointegrated (OI) prostheses directly connect an artificial limb to the residual appendicular skeleton via a permanently implanted endoprosthesis with a bridging connector that protrudes through the skin. The resulting stoma produces unique medical and biological challenges. Previously, a study using a large animal amputation model indicated that infection could be largely prevented, for at least a 12-month period, but the terminal epithelium continued to downgrow. The current study was undertaken to test the longer-term efficacy of this implant construct to maintain a stable skin-implant interface for 24 months. Using the previously successful amputation and implantation surgical procedure, a total of eight sheep were fitted with a percutaneous OI prosthesis. Two animals were removed from the study due to early complications. Of the remaining six sheep, one (16.7%) became infected at 15-months post-implantation and five remained infection-free for the intended 24 months. The histological data of the remaining animals further confirmed the grossly observable epithelial downgrowth. Albeit a receding interface, it was clear that all animals that survived to the end of the study had residual fibrous soft-tissue ingrowth into, and debris within, the exposed titanium porous-coated surface. Overall, the data demonstrated that the porous coated subdermal barrier offered initial protection against infection. However, the fibrous skin attachment was continuously lysed over time by the down-growing epithelium.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Wound Healing and Treatments · Reconstructive Surgery and Microvascular Techniques · Reconstructive Facial Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Branemark P-I, Chien S. The osseointegration book: from calvarium to calcaneus. Berlin, London: Quintessenz; 2005.
2. Pendegrass CJ, Goodship AE, Blunn GW. Development of a soft tissue seal around bone-anchored transcutaneous amputation prostheses. Biomaterials. 2006;27:4183–91.10.1016/j.biomaterials.2006.03.041 ↗
3. Kang NV, Pendegrass C, Marks L, Blunn G. Osseocutaneous integration of an intraosseous transcutaneous amputation prosthesis implant used for reconstruction of a transhumeral amputee: case report. J Hand Surg. 2010;35:1130–4.10.1016/j.jhsa.2010.03.037 ↗
4. Juhnke DL, Beck JP, Jeyapalina S, Aschoff HH. Fifteen years of experience with Integral-Leg-Prosthesis: cohort study of artificial limb attachment system. J Rehabil Res Dev. 2015;52:407–20.10.1682/JRRD.2014.11.0280 ↗
5. Kang NV, Morritt D, Pendegrass C, Blunn G. Use of ITAP implants for prosthetic reconstruction of extra-oral craniofacial defects. J Plast Reconstr Aesthet Surg. 2013;66:497–505.10.1016/j.bjps.2012.11.036 ↗
6. Jeyapalina S, Beck JP, Bachus KN, Bloebaum RD. Cortical bone response to the presence of load-bearing percutaneous osseointegrated prostheses. Anat Rec. 2012;295:1437–45.10.1002/ar.22533 ↗
7. Aschoff HH, Kennon RE, Keggi JM, Rubin LE. Transcutaneous, distal femoral, intramedullary attachment for above-the-knee prostheses: an endo-exo device. J Bone Joint Surg Am. 2010;92:180–6.10.2106/JBJS.J.00806 ↗
8. Aschoff HH. The endo-exo-femoral prosthesis. Traumatol Orthop Surg Russia. 2011;1:101–5.
9. Al Muderis M, Khemka A, Lord SJ, Van de Meent H, Frolke JP. Safety of osseointegrated implants for transfemoral amputees: a two-center prospective cohort study. J Bone Joint Surg Am. 2016;98:900–9.10.2106/JBJS.15.00808 ↗
10. Hagberg K, Branemark R. One hundred patients treated with osseointegrated transfemoral amputation prostheses—rehabilitation perspective. J Rehabil Res Dev. 2009;46:331–44.10.1682/JRRD.2008.06.0080 ↗
11. Hagberg K, Branemark R, Gunterberg B, Rydevik B. Osseointegrated trans-femoral amputation prostheses: prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up. Prosthet Orthot Int. 2008;32:29–41.10.1080/03093640701553922 ↗
12. Rydevik B, Shubayev VI, Myers RR. Osseoperception. In: Brånemark P-I, Chien S, Gröndahl H-G, Robinson K, editors. The osseointegration book from calvarium to calcaneus. Berlin: Quintessenz; 2005. p. 149–56.
13. Jacobs R, Van Steenberghe D. From osseoperception to implant-mediated sensory-motor interactions and related clinical implications. J Oral Rehabil. 2006;33:282–92.10.1111/j.1365-2842.2006.01621.x ↗
14. Hagberg K, Haggstrom E, Jonsson S, Rydevik B, Branemark R. Osseoperception and osseointegrated prosthetic limbs. Psychoprosthetics. London: Springer; 2008. p. 131–40.10.1007/978-1-84628-980-4_10 ↗
15. Klineberg I. Introduction: from osseointegration to osseoperception. The functional translation. Clin Exp Pharmacol Physiol. 2005;32:97–9.10.1111/j.1440-1681.2005.04135.x ↗
16. Branemark R, Berlin O, Hagberg K, Bergh P, Gunterberg B, Rydevik B. A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: a prospective study of 51 patients. Bone Joint J. 2014;96B:106–13.10.1302/0301-620X.96B1.31905 ↗
17. Tillander J, Hagberg K, Hagberg L, Branemark R. Osseointegrated titanium implants for limb prostheses attachments: infectious complications. Clin Orthop Relat Res. 2010;468:2781–8.10.1007/s11999-010-1370-0 ↗
18. Tsikandylakis G, Berlin O, Branemark R. Implant survival, adverse events, and bone remodeling of osseointegrated percutaneous implants for transhumeral amputees. Clin Orthop Relat Res. 2014;472:2947–56.10.1007/s11999-014-3695-6 ↗
19. Jeyapalina S, Beck JP, Bachus KN, Williams DL, Bloebaum RD. Efficacy of a porous-structured titanium subdermal barrier for preventing infection in percutaneous osseointegrated prostheses. J Orthop Res. 2012;30:1304–11.10.1002/jor.22081 ↗
20. Holt BM, Bachus KN, Beck JP, Bloebaum RD, Jeyapalina S. Immediate post-implantation skin immobilization decreases skin regression around percutaneous osseointegrated prosthetic implant systems. J Biomed Mater Res A. 2013;101:2075–82.10.1002/jbm.a.34510 ↗
21. Holt BM, Betz DH, Ford TA, Beck JP, Bloebaum RD, Jeyapalina S. Pig dorsum model for examining impaired wound healing at the skin-implant interface of percutaneous devices. J Mater Sci Mater Med. 2013;24:2181–93.10.1007/s10856-013-4975-5 ↗
22. Isackson D, McGill LD, Bachus KN. Percutaneous implants with porous titanium dermal barriers: an in vivo evaluation of infection risk. Med Eng Phys. 2011;33:418–26.10.1016/j.medengphy.2010.11.007 ↗
23. Mitchell SJ, Jeyapalina S, Nichols FR, Agarwal J, Bachus KN. Negative pressure wound therapy limits downgrowth in percutaneous devices. Wound Repair Regen. 2016;24:35–44.10.1111/wrr.12373 ↗
24. von Recum AF. Applications and failure modes of percutaneous devices: a review. J Biomed Mater Res. 1984;18:323–36.10.1002/jbm.820180403 ↗
25. Shelton TJ, Beck JP, Bloebaum RD, Bachus KN. Percutaneous osseointegrated prostheses for amputees: limb compensation in a 12-month ovine model. J Biomech. 2011;44:2601–6.10.1016/j.jbiomech.2011.08.020 ↗
26. Emmanual J, Hornbeck C, Bloebaum RD. A polymethyl methacrylate method for large specimens of mineralized bone with implants. Stain Technol. 1987;62:401–10.10.3109/10520298709108030 ↗
27. Freedberg IM, Tomic-Canic M, Komine M, Blumenberg M. Keratins and the keratinocyte activation cycle. J Invest Dermatol. 2001;116:633–40.10.1046/j.1523-1747.2001.01327.x ↗
28. Tomic-Canic M, Komine M, Freedberg IM, Blumenberg M. Epidermal signal transduction and transcription factor activation in activated keratinocytes. J Dermatol Sci. 1998;17:167–81.10.1016/S0923-1811(98)00016-4 ↗
29. Gerritsen M, Lutterman JA, Jansen JA. Wound healing around bone-anchored percutaneous devices in experimental diabetes mellitus. J Biomed Mater Res. 2000;53:702–9.10.1002/1097-4636(2000)53:6<702::AID-JBM13>3.0.CO;2-V ↗
30. Gerritsen M, Lutterman JA, Jansen JA. The influence of impaired wound healing on the tissue reaction to percutaneous devices using titanium fiber mesh anchorage. J Biomed Mater Res. 2000;52:135–41.10.1002/1097-4636(200010)52:1<135::AID-JBM17>3.0.CO;2-I ↗
31. Jansen JA, Paquay YG, van der Waerden JP. Tissue reaction to soft-tissue anchored percutaneous implants in rabbits. J Biomed Mater Res. 1994;28:1047–54.10.1002/jbm.820280909 ↗
32. Jansen JA, van der Waerden JP, de Groot K. Epithelial reaction to percutaneous implant materials: in vitro and in vivo experiments. J Invest Surg. 1989;2:29–49.10.3109/08941938909016502 ↗
33. Chehroudi B, Brunette DM. Subcutaneous microfabricated surfaces inhibit epithelial recession and promote long-term survival of percutaneous implants. Biomaterials. 2002;23:229–37.10.1016/S0142-9612(01)00100-4 ↗
34. Pendegrass CJ, Goodship AE, Price JS, Blunn GW. Nature’s answer to breaching the skin barrier: an innovative development for amputees. J Anat. 2006;209:59–67.10.1111/j.1469-7580.2006.00595.x ↗
35. Sullivan J, Uden M, Robinson KP, Sooriakumaran S. Rehabilitation of the trans-femoral amputee with an osseointegrated prosthesis: the United Kingdom experience. Prosthet Orthot Int. 2003;27:114–20.10.1080/03093640308726667 ↗
36. Jansen JA, van der Waerden JP, van der Lubbe HB, de Groot K. Tissue response to percutaneous implants in rabbits. J Biomed Mater Res. 1990;24:295–307.10.1002/jbm.820240303 ↗
37. Hugate R, Clarke R, Hoeman T, Friedman A. Transcutaneous implants in a porcine model: the use of highly porous tantalum. Int J Adv Mater Res. 2015;1:32–40.