Analysis of sintered polymer scaffolds using concomitant synchrotron computed tomography and in situ mechanical testing
Source abstract
Abstract
The mechanical behaviour of polymer scaffolds plays a vital role in their successful use in bone tissue engineering. The present study utilised novel sintered polymer scaffolds prepared using temperature-sensitive poly(DL-lactic acid-co-glycolic acid)/poly(ethylene glycol) particles. The microstructure of these scaffolds was monitored under compressive strain by image-guided failure assessment (IGFA), which combined synchrotron radiation computed tomography (SR CT) and in situ micro-compression. Three-dimensional CT data sets of scaffolds subjected to a strain rate of 0.01%/s illustrated particle movement within the scaffolds with no deformation or cracking. When compressed using a higher strain rate of 0.02%/s particle movement was more pronounced and cracks between sintered particles were observed. The results from this study demonstrate that IGFA based on simultaneous SR CT imaging and micro-compression testing is a useful tool for assessing structural and mechanical scaffold properties, leading to further insight into structure-function relationships in scaffolds for bone tissue engineering applications.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Mosekilde L. Age-related changes in vertebral trabecular bone architecture—assessed by a new method. Bone. 1988;9:247–50.10.1016/8756-3282(88)90038-5 ↗
2. Müller R, Hannan M, Smith SY, Bauss F. Intermittent ibandronate preserves bone quality and bone strength in the lumbar spine after 16 months of treatment in the ovariectomized cynomolgus monkey. J Bone Miner Res. 2004;19:1787–96.10.1359/JBMR.040809 ↗
3. Goulet RW, Goldstein SA, Ciarelli MJ, Kuhn JL, Brown MB, Feldkamp LA. The relationship between the structural and orthogonal compressive properties of trabecular bone. J Biomech. 1994;27:375–89.10.1016/0021-9290(94)90014-0 ↗
4. Langer R, Vacanti JP. Tissue engineering. Science. 1993;260:920–6.10.1126/science.8493529 ↗
5. Salgado AJ, Coutinho OP, Reis RL. Bone tissue engineering: state of the art and future trends. Macromol Biosci. 2004;4:743–65.10.1002/mabi.200400026 ↗
6. Jones JR, Lee PD, Hench LL. Heirarchical porous materials for tissue engineering. Philos Transact A Math Phys Eng Sci. 2006;364:263–81.10.1098/rsta.2005.1689 ↗
7. Yang S, Leong KF, Du Z, Chua CK. The design of scaffolds for use in tissue engineering. Part I. Tradit Factors. 2001;7:679–89.
8. Bignon A, Chouteau J, Chevalier J, Fantozzi G, Carret JP, Chavassieux P, Boivin G, Melin M, Hartmann D. Effect of micro- and macroporosity of bone substitutes on their mechanical properties and cellular response. J Mater Sci Mater Med. 2003;14:1089–97.10.1023/B:JMSM.0000004006.90399.b4 ↗
9. Jin QM, Takita H, Kohgo T, Atsumi K, Itoh H, Kuboki Y. Effects of geometry of hydroxyapatite as a cell substratum in BMP-induced ectopic bone formation. J Biomed Mater Res A. 2000;51:491–9.10.1002/1097-4636(20000905)51:3<491::AID-JBM25>3.0.CO;2-1 ↗
10. Kaito T, Myoui A, Takaoka K, Saito N, Nishikawa M, Tamai N, Ohgushi H, Yoshikawa H. Potentiation of the activity of bone morphogenetic protein-2 in bone regeneration by a PLA/PEG/hydroxyapatite composite. Biomaterials. 2005;26:73–9.10.1016/j.biomaterials.2004.02.010 ↗
11. Marra KG, Szem JW, Kumta PN, DiMilla PA, Weiss LE. In vitro analysis of biodegradable polymer blend/hydroxyapatite composites for bone tissue engineering. J Biomed Mater Res. 1999;47:324–35.10.1002/(SICI)1097-4636(19991205)47:3<324::AID-JBM6>3.0.CO;2-Y ↗
12. Babout L, Ludwig W, Maire E, Buffiere JY. Damage assessment in metallic structural materials using high resolution synchrotron X-ray tomography. Nucl Instrum Methods Phys Res, B Beam Interact Mater Atoms. 2003;200:303–7.10.1016/S0168-583X(02)01692-0 ↗
13. Elliott JA, Windle AH, Hobdell JR, Eeckhaut G, Oldman RJ, Ludwig W, Boller E, Cloetens P, Baruchel J. In situ deformation of an open-cell flexible polyurethane foam characterised by 3D computed microtomography. J Mater Sci. 2002;37:1547–55.10.1023/A:1014920902712 ↗
14. Müller R, Gerber SC, Hayes WC. Micro-compression: a novel technique for the non-destructive assessment of local bone failure. Technol Health Care. 1998;6:433–44.10.3233/THC-1998-65-616 ↗
15. Nazarian A, Müller R. Time-lapsed microstructural imaging of bone failure behaviour. J Biomech. 2004;37:55–65.10.1016/S0021-9290(03)00254-9 ↗
16. Thurner PJ, Wyss P, Voide R, Stauber M, Stampanoni M, Sennhauser U, Müller R. Time-lapsed investigation of three-dimensional failure and damage accumulation in trabecular bone using synchrotron light. Bone. 2006;39:289–99.10.1016/j.bone.2006.01.147 ↗
17. Voide R, Schneider P, Stauber M, Wyss P, Stampanoni M, Sennhauser U, van Lenthe GH, Müller R. Time-lapsed assessment of microcrack initiation and propagation in murine cortical bone at submicrometer resolution. Bone. 2009;45:164–73.10.1016/j.bone.2009.04.248 ↗
18. Schneider P, Levchuk A, Müller R. Automated micro-compression device for dynamic image-guided failure assessment of bone ultrastructure and bone microdamage. Biomed Tech. 2010;55:8–10.
19. Coombes AG, Heckman JD. Gel casting of resorbable polymers 2. In vitro degradation of bone graft substitutes. Biomaterials. 1992;13:297–307.10.1016/0142-9612(92)90053-Q ↗
20. Howard D, Buttery LD, Shakesheff KM, Roberts SJ. Tissue engineering: strategies, stem cells and scaffolds. J Anat. 2008;213:66–72.10.1111/j.1469-7580.2008.00878.x ↗
21. Hamilton L, France RM, Shakesheff KM. Development of an injectable scaffold for application in regenerative medicine to deliver stem cells and growth factors. J Pharm Pharmacol. 2006;58:52–3.
22. Stampanoni M, Groso A, Isenegger A, Mikuljan G, Chen Q, Meister D, Lange M, Betemps R, Henein S, Abela R. TOMCAT: a beamline for tomographic microscopy and coherent radiology experiments. AIP Conf Proc. 2007;879:848–51.10.1063/1.2436193 ↗
23. Misch CE, Qu Z, Bidez MW. Mechanical properties of trabecular bone in the human mandible: implications for dental implant treatment planning and surgical placement. J Oral Maxillofac Surg. 1999;57:700–6.10.1016/S0278-2391(99)90437-8 ↗
24. Teo JC, Chui CK, Wang ZL, Ong SH, Yan CH, Wang SC, Wong HK, Teoh SH. Heterogenous meshing and biomechanical modelling of human spine. Med Eng Phys. 2007;29:277–90.10.1016/j.medengphy.2006.02.012 ↗
25. Kopperdahl DL, Keaveny TM. Yield strain behaviour of trabecular bone. J Biomech. 1998;31:601–8.10.1016/S0021-9290(98)00057-8 ↗
26. Charles-Harris M, del Valle S, Hentges E, Bleuet P, Lacroix D, Planell JA. Mechanical and structural characterisation of completely degradable polylactic acid/calcium phosphate glass scaffolds. Biomaterials. 2007;28:4429–38.10.1016/j.biomaterials.2007.06.029 ↗
27. Yue S, Lee PD, Poologasundarampillai G, Yao Z, Rockett P, Devlin AH, Mitchell CA, Konerding MA, Jones JR. Synchrotron X-ray microtomography for assessment of bone tissue scaffolds. J Mater Sci Mater Med. 2010;21:847–53.10.1007/s10856-009-3888-9 ↗