journal article·2014-05

Cytotoxic, hematologic and histologic effects of niobium pentoxide in Swiss mice

Nuha Ahmad Dsouki, Maurício Pereira de Lima, Roseli Corazzini, Thaís Moura Gáscon, Ligia Ajaime Azzalis, Virgínia Berlanga Campos Junqueira, David Feder, Fernando Luiz Affonso Fonseca

Publisher page

Abstract

The use of metal devices in medical application is increasing but it remains incompletely understood the physiological effects of component degradation. Niobium (Nb) alloys have already been investigated in the 1980's and recent studies demonstrated the potential of Nb as an implant material. The purpose of this study was to determine cytotoxic, hematologic and histologic effects of niobium in Swiss mice. Animals were treated with a single dose of 3 % niobium oxide (Nb2O5) diluted in PBS, i.p. Cytotoxic assay, hematologic and histologic evaluation were done 3, 7 and 12 days after niobium treatment. Data have shown increased number of cells after niobium treatment, but there was no difference in cell viability. Furthermore, it was not observed hematological modification 3, 7 or 12 days after niobium treatment. Despite the fact that animals treated with niobium for 3 and 7 days showed mild degeneration in hepatocytes, mice kept alive for 12 days showed liver cells regeneration. Our results suggested that niobium cytotoxicity was not progressive because 12 days after treatment there was an evident liver regeneration. Data obtained indicated that niobium may be promising alternatives to biomedical applications.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Titanium Alloys Microstructure and Properties · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (16)

Show source-provided references
1. Sista S, Wen C, Hodgson PD, Pande G. The influence of surface energy of titanium–zirconium alloy on osteoblast cell functions in vitro. J Biomed Mater Res Part A. 2011;97A:27–36.10.1002/jbm.a.33013 ↗
2. Niinomi M, Nakai M, Hieda J. Development of new metallic alloys for biomedical applications. Acta Biomater. 2012;8:3888–903.10.1016/j.actbio.2012.06.037 ↗
3. Rubitschek F, Niendorf T, Karaman I, Maier HJ. Corrosion fatigue behavior of a biocompatible ultrafine-grained niobium alloy in simulated body fluid. J Mech Behav Biomed Mater. 2011;5:181–92.10.1016/j.jmbbm.2011.08.023 ↗
4. Leitune VCB, Collares FM, Takimi A, de Lima GB, Petzhold CL, Bergmann CP, Samuel SMW. Niobium pentoxide as a novel filler for dental adhesive resin. J Dent. 2013;41(2):106–13. doi: 10.1016/j.jdent.2012.04.022 .10.1016/j.jdent.2012.04.022 ↗
5. Wilmes S, Zwick G. Effect of niobium and vanadium as an alloying element in tool steels with high chromium content. In: The Use of Tool Steels: Experience and Re-search. 2002;1: 227–243
6. Braic V, Balaceanu M, Braic M, Vladescu A, Panseri S, Russo A. Characterization of multi-principal-element (TiZrNbHfTa)N and (TiZrNbHfTa)C coatings for biomedical applications. J Mech Behav Biomed Mater. 2012;10:197–205.10.1016/j.jmbbm.2012.02.020 ↗
7. Olivares-Navarrete R, Olaya JJ, Ramírez C, Rodil SE. Biocompatibility of niobium coatings. Coatings. 2011;1:72–87.10.3390/coatings1010072 ↗
8. Matsuno H, Yokoyama A, Watari F, Uo M, Kawasaki T. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials. 2011;22:1253–62.10.1016/S0142-9612(00)00275-1 ↗
9. Semlitsch MF, Weber H, Sttreicher RM, Schön R. Joint replacement components made of hot-forged and surface-treated Ti–6Al–7Nb alloy. Biomaterials. 1992;13:781–8.10.1016/0142-9612(92)90018-J ↗
10. Godmann SB, Davidson JA, Fornasier VL, Mishra AK. Histological response to cylinders of a low modulus titanium alloy (Ti–13Nb–13Zr) and a wear resistant zirconium alloy (Zr–2.5Nb) implanted in the rabbit tibia. J Appl Biomater. 1993;4:331–9.10.1002/jab.770040407 ↗
11. Yamamoto A, Honma R, Sumita M. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells. J Biomed Mater Res. 1998;39:331–40.10.1002/(SICI)1097-4636(199802)39:2<331::AID-JBM22>3.0.CO;2-E ↗
12. Metikoš-Huković M, Kwokal A, Piljac J. The influence of niobium and vanadium on passivity of titanium-based implants in physiological solution. Biomaterials. 2003;24:3765–75.10.1016/S0142-9612(03)00252-7 ↗
13. McMahon RE, Ma J, Verkhoturov SV, Munoz-Pinto D, Karaman I, Rubitschek F, Maier HJ, Hahn MS. A comparative study of the cytotoxicity and corrosion resistance of nickel–titanium and titanium–niobium shape memory alloys. Acta Biomater. 2012;8:2863–70.10.1016/j.actbio.2012.03.034 ↗
14. Challa VSA, Mali S, Misra RDK. Reduced toxicity and superior cellular response of preosteoblasts to Ti–6Al–7Nb alloy and comparison with Ti–6Al–4V. J Biomed Mater Res Part A. 2013;101(7):2083–9. doi: 10.1002/jbm.a.34492 .10.1002/jbm.a.34492 ↗
15. Fraqueza G, Ohlin CA, Casey WH, Aureliano M. Sarcoplasmic reticulum calcium ATPase interactions with decaniobate, decavanadate, vanadate, tungstate and molybdate. J Inorg Biochem. 2012;107:82–9.10.1016/j.jinorgbio.2011.10.010 ↗
16. Fraqueza G, de Carvalho LAEB, Marques MPM, Maia L, Ohlin CA, Casey WHM, Aureliano M. Decavanadate, decaniobate, tungstate and molybdate interactions with sarcoplasmic reticulum Ca(2+)-ATPase: quercetin prevents cysteine oxidation by vanadate but does not reverse ATPase inhibition. Dalton Trans. 2012;41:12749–58.10.1039/c2dt31688a ↗