journal article·2013-04

Effect of silver nanocoatings on catheters for haemodialysis in terms of cell viability, proliferation, morphology and antibacterial activity

F. Paladini, M. Pollini, D. Deponti, A. Di Giancamillo, G. Peretti, A. Sannino

Publisher page

Abstract

The onset of infections associated to bacterial proliferation and biofilm formation on indwelling medical devices represents the major risk of morbidity and mortality among patients. In order to contain the risk of infections in clinical practice, there is a growing interest nowadays in silver-based products due to the strong antimicrobial efficacy of silver against a broad spectrum of microorganisms. In this work, temporary catheters for haemodialysis were coated with silver nano-particles through the in situ photo-reduction of a silver salt in alcoholic solution. A homogeneous distribution of silver particles firmly bonded to the substrate was obtained through the adopted technique. An optimisation study was required to define the amount of silver, in order to obtain good efficacy against Gram-positive and Gram-negative bacteria and no cytotoxic effect. At this purpose, three concentrations of silver, 0.1, 0.25 and 0.5 wt%, have been deposited and tested with respect to bacterial reduction percentage and cellular response. Particularly, bacterial enumeration on Escherichia coli and Staphylococcus aureus, and BrdU incorporation, TUNEL assay and Actin staining on a selected primary cell population were performed on catheters treated with the different silver solutions. The silver percentages tested demonstrated strong antibacterial properties together with a good cellular response, thus indicating that the developed product could be proposed in clinical practice and that the lower percentage tested can be preferred with evident advantages in terms of costs.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Central Venous Catheters and Hemodialysis · Infection Control in Healthcare · Infectious Aortic and Vascular Conditions

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Parker MG, Doebbeling BN. The challenge of methicillin-resistant Staphylococcus aureus prevention in hemodialysis therapy. Semin Dial. 2012;25:42–9.10.1111/j.1525-139X.2011.00999.x ↗
2. Donlan RM. Biofilm formation: a clinically relevant microbiological process. Clin Infect Dis. 2001;33:1387–92.10.1086/322972 ↗
3. Sousa C, Henriques M, Oliveira R. Mini-review: antimicrobial central venous catheters—recent advances and strategies. Biofouling. 2011;27:609–20.10.1080/08927014.2011.593261 ↗
4. Mermel LA. What is the predominant source of intravascular catheter infections? Clin Infect Dis. 2011;52:211–2.10.1093/cid/ciq108 ↗
5. Beathard GA, Urbanes A. Infection associated with tunneled hemodialysis catheters. Semin Dial. 2008;21:528–38.10.1111/j.1525-139X.2008.00497.x ↗
6. Maya ID. Antibiotic lock for treatment of tunneled hemodialysis catheter bacteremia. Semin Dial. 2008;21:539–41.10.1111/j.1525-139X.2008.00498.x ↗
7. Dwyer A. Surface-treated catheters—a review. Semin Dial. 2008;21:542–6.10.1111/j.1525-139X.2008.00499.x ↗
8. Trautner BW, Darouiche RO. Catheter-associated infections pathogenesis affects prevention. Arch Intern Med. 2004;164:842–50.10.1001/archinte.164.8.842 ↗
9. Timsit JF, et al. New materials and devices for preventing catheter-related infections. Ann Intensive Care. 2011;1:34.10.1186/2110-5820-1-34 ↗
10. Loertzer H, Soukup J, Hamza A, Wicht A, Rettkowski O, Koch E, Fornara P. Use of catheters with the AgION antimicrobial system in kidney transplant recipients to reduce infection risk. Transplant Proc. 2006;38:707–10.10.1016/j.transproceed.2006.01.064 ↗
11. Roe D, Karandikar B, Bonn-Savage N, Gibbins B, Roullet JB. Antimicrobial surface functionalization of plastic catheters by silver nanoparticles. J Antimicrob Chemother. 2008;61:869–76.10.1093/jac/dkn034 ↗
12. Pollini M, Sannino A, Maffezzoli A, Licciulli A. Antibacterial surface treatments based on silver clusters deposition. European Patent No. EP1986499, 2008.
13. Pollini M, Paladini F, Catalano M, Taurino A, Licciulli A, Maffezzoli A, Sannino A. Antibacterial coatings on haemodialysis catheters by photochemical deposition of silver nanoparticles. Mater Sci Mater Med. 2011;22:2005–12.10.1007/s10856-011-4380-x ↗
14. Paladini F, Pollini M, Talà A, Alifano P, Sannino A. Efficacy of silver treated catheters for haemodialysis in preventing bacterial adhesion. J Mater Sci Mater Med. 2012;23:1983–90.10.1007/s10856-012-4674-7 ↗
15. Pollini M, Paladini F, Licciulli A, Maffezzoli A, Sannino A. Engineering nanostructured silver coatings for antimicrobial applications. In: Cioffi N, Rai M, editors. Nanoantimicrobials progress and prospects. New York: Springer; 2012. p. 313–336.10.1007/978-3-642-24428-5_11 ↗
16. Pollini M, Paladini F, Licciulli A, Maffezzoli A, Nicolais L, Sannino A. Silver coated wool yarns with durable antibacterial properties. J Appl Polym Sci. 2012;125:2239–44.10.1002/app.36444 ↗
17. Pollini M, Russo M, Licciulli A, Sannino A, Maffezzoli A. Characterization of antibacterial silver coated yarns. Mater Sci Mater Med. 2009;20:2361–6.10.1007/s10856-009-3796-z ↗
18. Deponti D, Di Giancamillo A, Mangiavini L, Pozzi A, Fraschini G, Sosio C, Domeneghini C, Peretti GM. Fibrin-based model for cartilage regeneration: tissue maturation from in vitro to in vivo. Tissue Eng Part A. 2012;18(11–12):1109–22.10.1089/ten.tea.2011.0272 ↗
19. Adal KA, Farr BM. Central venous catheter-related infections: a review. Nutrition. 1996;12:208–13.10.1016/S0899-9007(96)91126-0 ↗
20. Wang IK, et al. Bacteremia in hemodialysis and peritoneal dialysis patients. Intern Med. 2012;51:1015–21.10.2169/internalmedicine.51.7111 ↗
21. Shah CB, Mittelman MW, Costerton JW, Parenteau S, Pelak M, Arsenault R, Mermel LA. Antimicrobial activity of a novel catheter lock solution. Antimicrob Agents Chemother. 2002;46:1674–9.10.1128/AAC.46.6.1674-1679.2002 ↗
22. Timsit JF. Diagnosis and prevention of catheter-related infections. Curr Opin Crit Care. 2007;13:563–71.10.1097/MCC.0b013e3282efa03f ↗
23. Chaudhury A, Rangineni J. Catheter lock technique: in vitro efficacy of ethanol for eradication of methicillin-resistant staphylococcal biofilm compared with other agents. FEMS Immunol Med Microbiol. 2012;65:305–8.10.1111/j.1574-695X.2012.00950.x ↗
24. Steczko J, Ash SR, Nivens DE, Brewer L, Winger RK. Microbial inactivation properties of a new antimicrobial/antithrombotic catheter lock solution (citrate/methylene blue/parabens). Nephrol Dial Transpl. 2009;24:1937–45.10.1093/ndt/gfn776 ↗
25. Shanks RM, et al. Heparin stimulates Staphylococcus aureus biofilm formation. Infect Immun. 2005;73:4596–606.10.1128/IAI.73.8.4596-4606.2005 ↗
26. Shanks RM, Sargent JL, Martinez RM, Graber ML, O’Toole GA. Catheter lock solutions influence staphylococcal biofilm formation on abiotic surfaces. Nephrol Dial Transpl. 2006;21:2247–55.10.1093/ndt/gfl170 ↗
27. Mermel LA. New technologies to prevent intravascular catheter-related bloodstream infections. Emerg Infect Dis. 2001;7:197–9.10.3201/eid0702.010208 ↗
28. Shintani H. Modification of medical device surface to attain anti-infection. Trends Biomater Artif Organs. 2004;18:1–8.
29. Tobin EJ, Bambauer R. Silver coating of dialysis catheters to reduce bacterial colonization and infection. Ther Apher Dial. 2003;7:504–9.10.1046/j.1526-0968.2003.00097.x ↗