Silver doped hydroxyapatite coatings by sacrificial anode deposition under magnetic field
Source abstract
Abstract
Uniform distribution of silver (Ag) in the hydroxyapatite (HA) coated Ti surface has been a concern for which an attempt has been made to dope Ag in HA coating with and without magnetic field. Cathodic deposition technique was employed to coat Ag incorporated hydroxyapatite coating using a sacrificial silver anode method by using NdFeB bar magnets producing 12 Tesla magnetic field. While uniform deposition of Ag was observed in the coatings under magnetic field, dense coating was evident in the coating without magnetic field conditions. Uniformly distributed Ag incorporated HA in the present study has potential to fight microorganism while providing osseoconduction properties of the composite coating.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing Materials and Processes · Calcium Carbonate Crystallization and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (30)
Show source-provided references
1. Rautray TR, Narayanan R, Kim KH. Ion implantation of titanium based biomaterials. Prog Mater Sci. 2011;56:1137–77.10.1016/j.pmatsci.2011.03.002 ↗
2. Rautray TR, Narayanan R, Kwon TY, Kim KH. Accelerator based synthesis of hydroxyapatite by MeV ion implantation. Thin Solid Films. 2010;518:3160–3.10.1016/j.tsf.2009.08.044 ↗
3. Rautray TR, Narayanan R, Kwon TY, Kim KH. Surface modification of titanium and titanium alloys by ion implantation – a review. Analysis of Human bone and teeth. J Biomed Mater Res. 2010;93B:581–91.10.1002/jbm.b.31596 ↗
4. Rautray TR, Mishra S, Patnaik SK, Vijayan V, Panigrahi S. Synthesis of hydroxyapatite at low temperature. In situ analysis of human teeth by external PIXE. Ind J Phys. 2007;81(1):99–102.
5. Rautray TR, Vijayan V, Panigrahi S. Synthesis of hydroxyapatite at low temperature. Ind J Phys. 2007;81(1):95–8.
6. Rautray TR, Das SL, Rautray AC. In situ analysis of human teeth by external PIXE. Nucl Instrum Meth Phys Res B. 2010;268(14):2371–4.10.1016/j.nimb.2010.01.004 ↗
7. Lee KW, Bae CM, Jung JY, Sim GB, Rautray TR, Lee HJ, Kwon TY, Kim KH. Surface characteristics and biological studies of hydroxyapatite coating by a new method. J Biomed Mater Res. 2011;98B:395–407.10.1002/jbm.b.31864 ↗
8. Yang JH, Kim KH, You CK, Rautray TR, Kwon TY. Synthesis of spherical hydroxyapatite granules with interconnected pore channels using camphene emulsion. J Biomed Mater Res. 2011;99B(1):150–7.10.1002/jbm.b.31882 ↗
9. Rautray TR, Swain S, Kim KH. Formation of anodic TiO2 nanotubes under magnetic field. Adv Sci Lett. 2014;20:801–3.10.1166/asl.2014.5423 ↗
10. Kim KH, Narayanan N, Rautray TR. Surface modification of titanium for biomaterial applications. USA: Nova publishers; 2011.
11. Rautray TR, Mohapatra B, Kim KH. Fabrication of strontium – hydroxyapatite scaffolds for biomedical applications. Adv Sci Lett. 2014;20:879–81.10.1166/asl.2014.5424 ↗
12. Knabe C, Howlett CR, Klar F, Zreiqat H. The effect of different titanium and hydroxyapatite coated dental implant surfaces on phenotypic expression of human bone-derived cells. J Biomed Mater Res A. 2004;71:98–107.10.1002/jbm.a.30130 ↗
13. Norowski PA, Bumgardner JD. Biomaterial and antibiotic strategies for peri implantitis. J Biomed Mater Res. 2009;88B:530–43.10.1002/jbm.b.31152 ↗
14. Shi ZL, Chua PH, Neoh KG, Kang ET, Wang W. Bioactive titanium implant surfaces with bacterial inhibition and osteoblast function enhancement properties. Int J Artif Organs. 2008;31:777–85.10.1177/039139880803100905 ↗
15. Darouuiche RO. Anti-infective efficacy of silver-coated medical prostheses. Clin Infect Dis. 1999;29:1371–7.10.1086/313561 ↗
16. Chen W, Liu Y, Courtney HS, Bettenga M, Agrawal CM, Bumgardner JD, Ong JL. In vitro anti-bacterial and biological properties of magnetron co-sputtered silver containing hydroxyapatite coating. Biomater. 2006;27:5512–7.10.1016/j.biomaterials.2006.07.003 ↗
17. Ruan HJ, Fan CY, Zheng XB, Zhang Y, Chen Y. In vitro antibacterial and osteogenic properties of plasma sprayed silver-containing hydroxyapatite coating. Chin Sci Bull. 2009;54:4438–45.10.1007/s11434-009-0175-6 ↗
18. Bai X, More K, Rouleau CM, Rabiei A. Functionally graded hydroxyapatite coatings doped with antibacterial components. Acta Biomater. 2010;6:2264–73.10.1016/j.actbio.2009.12.002 ↗
19. Narayanan R, Kim SY, Kwon TY, Kim KH. Nanocrystalline hydroxyapatite coatings from ultrasonated electrolyte: preparation, characterization, and osteoblast responses. J Biomed Mater Res A. 2008;87(4):1053–60.10.1002/jbm.a.31852 ↗
20. Swain S, Rautray TR, Narayanan R. Sr, Mg, and Co substituted hydroxyapatite coating on TiO2 nanotubes by electrochemical methods. Adv Sci Lett. 2016;22:482–7.10.1166/asl.2016.6888 ↗
21. Swain S, Rautray TR. Cu and Zn substituted hydroxyapatite coatings on TiO2 nanotubes formed by electrochemical methods. Innovare J Eng Technol. 2016;4(3):7–10.
22. Narayanan R, Kim SY, Kwon TY, Kim KH. Nanocrystalline hydroxyapatite coatings from ultrasonated electrolyte: preparation, characterization, and osteoblast responses. J Biomed Mater Res. 2008;87A:1053–60.10.1002/jbm.a.31852 ↗
23. Narayanan R, Kwon TY, Kim KH. Anodic TiO2 from stirred Na2SO4/NaF electrolytes: effect of applied voltage and stirring. Mater Lett. 2009;63:2003–6.10.1016/j.matlet.2009.06.036 ↗
24. Rameshbabu N, Kumar TSS, Prabhakar TG, Sastry VS, Murty KVGK, Rao KP. Antibacterial nanosized silver substituted hydroxyapatite: synthesis and characterization. J Biomed Mater Res. 2007;80A:581–91.10.1002/jbm.a.30958 ↗
25. Zhao K, Feng Q, Chen G. Antibacterial effects of silver loaded hydroxyapatite. Tsinghua Sci Technol. 1999;4:1570–3.
26. Rautray TR, Kim KH. Synthesis of silver incorporated hydroxyapatite under magnetic field. Key Eng Mater. 2012;493-494:181–5.10.4028/www.scientific.net/KEM.493-494.181 ↗
27. Tanimoto Y, Katsuki A, Yano H, Watanabe S. Effect of high magnetic field on the silver deposition from its aqueous solution. J Phys Chem A. 1997;101:7359–63.10.1021/jp971489u ↗
28. Choi JW, Cho HM, Kwak EK, Kwo TG, Ryoo HM, Jeong YK, Oh KS, Shin HI. Effect of Ag-doped hydroxyapatite as a bone filler for inflamed bone defects. Key Eng Mater. 2004;254–256:47–50.10.1016/j.msea.2004.05.068 ↗
29. Hardes J, Ahrens H, Gebert C, Streitbuerger A, Buerger H, Erren M, Gunsel A, Wedemeyer C, Saxler G, Winkelmann W, Gosheger G. Lack of toxicological side-effects in silver-coated megaprostheses in humans. Biomater. 2007;28(18):2869–75.10.1016/j.biomaterials.2007.02.033 ↗
30. Thian ES, Lim PN, Shi Z, Tay BY, Neoh KG. Silver-doped apatite as a bioactive and an antimicrobial bone material. Key Eng Mater. 2012;493-494:27–30.10.4028/www.scientific.net/KEM.493-494.27 ↗