journal article·2012-04

In vivo evaluation of titanium oxide and hydroxyapatite as an artificial cornea skirt

Xiao Wei Tan, Roger W. Beuerman, Zhi Long Shi, Koon Gee Neoh, Donald Tan, Khiam Aik Khor, Jodhbir S. Mehta

Publisher page

Abstract

Keratoprosthetic devices are subject to chronic inflammatory, pathological processes and the external environment that affect their stability and biocompatibility with the ocular surface and adjacent ocular tissues. We compared the corrosion resistance property and tissue-implant reaction of titanium oxide (TiO(2)) with hydroxyapatite (HA) in artificial tear fluid and a rabbit skin implantation model. The dissolution properties of the implant surfaces were evaluated with scanning electronic microscope (SEM) and atomic force microscope (AFM). Tissue inflammatory reactions were evaluated by Hematoxylin & Eosin staining, avidin biotin peroxidase complex (ABC) immunoassay and immunofluorescence. SEM and AFM images showed that there was less pitting corrosion on the surface of TiO(2) implants compared with HA. TiO(2) and HA exhibited a similar pattern of foreign body capsule formation and inflammatory cellular responses. The Collagen I/Collagen III ratio of the TiO(2) capsule was higher than that of the HA capsule. TiO(2) implants possess a high corrosion resistance property both in vitro and in vivo and the inflammatory cellular response to TiO(2) is similar to HA. With regards to corrosion resistance and inflammatory tissue responses, TiO(2) appears to be a promising material for keratoprosthetic skirt devices.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Corneal Surgery and Treatments · Ocular Surface and Contact Lens · Corneal surgery and disorders

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (32)

Show source-provided references
1. Liu C, Paul B, Tandon R, Lee E, Fong K, Mavrikakis I, Herold J, Thorp S, Brittain P, Francis I, Ferrett C, Hull C, Lloyd A, Green D, Franklin V, Tighe B, Fukuda M, Hamada S. The osteo-odonto-keratoprosthesis (OOKP). Semin Ophthalmol. 2005;20:113–28.10.1080/08820530590931386 ↗
2. Tan DT, Tay AB, Theng JT, Lye KW, Parthasarathy A, Por YM, Chan LL, Liu C. Keratoprosthesis surgery for end-stage corneal blindness in Asian eyes. Ophthalmology. 2008;115:503–10.10.1016/j.ophtha.2007.04.065 ↗
3. Tay AB, Tan DT, Lye KW, Theng J, Parthasarathy A, Por YM. Osteo-odonto-keratoprosthesis surgery: a combined ocular-oral procedure for ocular blindness. Int J Oral Maxillofac Surg. 2007;36:807–13.10.1016/j.ijom.2007.04.009 ↗
4. Falcinelli G, Falsini B, Taloni M, Colliardo P, Falcinelli G. Modified osteo-odonto-keratoprosthesis for treatment of corneal blindness: long-term anatomical and functional outcomes in 181 cases. Arch Ophthalmol. 2005;123:1319–29.10.1001/archopht.123.10.1319 ↗
5. Liu C, Okera S, Tandon R, Herold J, Hull C, Thorp S. Visual rehabilitation in end-stage inflammatory ocular surface disease with the osteo-odonto-keratoprosthesis: results from the UK. Br J Ophthalmol. 2008;92:1211–7.10.1136/bjo.2007.130567 ↗
6. Viitala R, Franklin V, Green D, Liu C, Lloyd A, Tighe B. Towards a synthetic osteo-odonto-keratoprosthesis. Acta Biomater. 2009;5:438–52.10.1016/j.actbio.2008.07.008 ↗
7. Polack FM, Heimke G. Ceramic keratoprostheses. Ophthalmology. 1980;87:693–8.10.1016/S0161-6420(80)35179-8 ↗
8. Polack FM. Clinical Results with a ceramic keratoprostheses. Cornea. 1983;2:185–96.
9. Matsuno H, Yokoyama A, Watari F, Uo M, Kawasaki T. Biocompatibility and osteogenesis of refractory metal implants, titanium, hafnium, niobium, tantalum and rhenium. Biomaterials. 2001;22:1253–62.10.1016/S0142-9612(00)00275-1 ↗
10. Thull R. Physicochemical principles of tissue material interactions. Biomol Eng. 2002;19:43–50.10.1016/S1389-0344(02)00009-6 ↗
11. Tan XW, Perera AP, Tan A, Tan D, Khor KA, Beuerman RW, Mehta JS. Comparison of candidate materials for a synthetic osteo-odonto keratoprosthesis device. Invest Ophthalmol Vis Sci. 2011;52:21–9.10.1167/iovs.10-6186 ↗
12. Huang HH. Surface characterizations and corrosion resistance of nickel–titanium orthodontic archwires in artificial saliva of various degrees of acidity. J Biomed Mater Res A. 2005;74:629–39.10.1002/jbm.a.30340 ↗
13. Alexeev VL, Das S, Finegold DN, Asher SA. Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid. Clin Chem. 2004;50:2353–60.10.1373/clinchem.2004.039701 ↗
14. Yuan SJ, Pehkonen SO. Microbiologically influenced corrosion of 304 stainless steel by aerobic Pseudomonas NCIMB 2021 bacteria: AFM and XPS study. Coll Surf B Biointerfaces. 2007;59:87–99.10.1016/j.colsurfb.2007.04.020 ↗
15. Tn S, editor. Histochemical and quantitative microscopy. New York: Macmillan; 1986.
16. Ward WK, Slobodzian EP, Tiekotter KL, Wood MD. The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants. Biomaterials. 2002;23:4185–92.10.1016/S0142-9612(02)00160-6 ↗
17. Lehle K, Lohn S, Reinerth GG, Schubert T, Preuner JG, Birnbaum DE. Cytological evaluation of the tissue-implant reaction associated with subcutaneous implantation of polymers coated with titaniumcarboxonitride in vivo. Biomaterials. 2004;25:5457–66.10.1016/j.biomaterials.2003.12.055 ↗
18. Shannon C, Thull R, von Recum A. Types I and III collagen in the tissue capsules of titanium and stainless-steel implants. J Biomed Mater Res. 1997;34:401–8.10.1002/(SICI)1097-4636(19970305)34:3<401::AID-JBM15>3.0.CO;2-I ↗
19. Ask M, Alausmaa J, Kasemo B. Preparation and surface spectroscopic characterization of oxide-films on Ti6Al4V. Appl Surf Sci. 1989;35:283–301.10.1016/0169-4332(89)90013-5 ↗
20. Lausmaa J, Kasemo B, Mattson H, Odelius H. Multitechnique surface characterization of oxide-films on electropolished and anodically oxidized titanium. Appl Surf Sci. 1990;45:189–200.10.1016/0169-4332(90)90002-H ↗
21. Ducheyne P, Willems G, Martens M, Helsen J. In vivo metal-ion release from porous titanium-fiber material. J Biomed Mater Res. 1984;18:293–308.10.1002/jbm.820180306 ↗
22. Healy KE, Ducheyne P. The mechanisms of passive dissolution of titanium in a model physiological environment. J Biomed Mater Res. 1992;26:319–38.10.1002/jbm.820260305 ↗
23. Healy KE, Ducheyne P. Oxidation-kinetics of titanium thin-films in model physiological environments. J Coll Interface Sci. 1992;150:404–17.10.1016/0021-9797(92)90210-D ↗
24. Earle MD. The electrical conductivity of titanium dioxide. Phys Rev. 1942;61:56–62.10.1103/PhysRev.61.56 ↗
25. Gittings JP, Bowen CR, Dent ACE, Turner IG, Baxter FR, Chaudhuri JB. Electrical characterization of hydroxyapatite-based bioceramics. Acta Biomater. 2009;5(743–754):26.
26. Burstein GT, Liu C, Souto RM. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer’s physiological solution. Biomaterials. 2005;26:245–56.10.1016/j.biomaterials.2004.02.023 ↗
27. Xu LC, Fang HHP, Chan KY. Atomic force microscopy study of microbiological influenced corrosion of mild steel. J Electrochem Soc. 1999;146:4455–60.10.1149/1.1392658 ↗
28. Anderson JM, Rodriguez A, Chang DT. Foreign body reaction to biomaterials. Semin Immunol. 2008;20:86–100.10.1016/j.smim.2007.11.004 ↗
29. Butler K, Benghuzzi H, Puckett A. Cytological evaluation of the tissue-implant reaction associated with S/C and I/P implantation of ALCAP and HA bioceramics in vivo. Pathol Res Pract. 2001;197:29–39.10.1078/0344-0338-00005 ↗
30. Laattala K, Huhtinen R, Puska M, Arstila H, Hupa L, Kellomäki M, Vallittu PK. Bioactive composite for keratoprosthesis skirt. J Mech Behav Biomed Mater. 2011;4:1700–8.10.1016/j.jmbbm.2011.05.025 ↗
31. Caldwell DR. The soft keratoprosthesis. Trans Am Ophthalmol Soc. 1997;95:751–802.
32. Birk DE, Mayne R. Localization of collagen types I, III and V during tendon development. Changes in collagen types I and III are correlated with changes in fibril diameter. Eur J Cell Biol. 1997;72:352–61.