journal article·2014-11Open access

Reduced fibroblast adhesion and proliferation on plasma-modified titanium surfaces

Sebastian Kuhn, Jennifer Kroth, Ulrike Ritz, Alexander Hofmann, Christian Brendel, Lars Peter Müller, Renate Förch, Pol Maria Rommens

Abstract

Soft tissue complications are clinically relevant problems after osteosynthesis of fractures. The goal is to develop a method for reduction of fibroblast adhesion and proliferation on titanium implant surfaces by plasma polymerisation of the organo-silicon monomer hexamethyldisiloxane (HMDSO). HMDSO was deposited under continuous wave conditions in excess oxygen (ppHMDSO surface) and selected samples were further modified with an additional oxygen plasma (ppHMDSO + O2 surface). Surface characterization was performed by scanning electron microscopy, profilometry, water contact angle measurements, infrared reflection absorption spectroscopy and X-ray photoelectron spectroscopy. In our experimental setup the mechanical properties, roughness and topography of the titanium were preserved, while surface chemistry was drastically changed. Fibroblast proliferation was assessed by alamarBlue assay, cell morphology by confocal microscopy visualization of eGFP-transducted fibroblasts, and cell viability by Annexine V/propidium iodide assay. Both modified surfaces, non-activated hydrophobic ppHMDSO and activated hydrophilic ppHMDSO + O2 were able to dramatically reduce fibroblast colonization and proliferation compared to standard titanium. However, this effect was more strongly pronounced on the hydrophobic ppHMDSO surface, which caused reduced cell adhesion and prevented proliferation of fibroblasts. The results demonstrate that plasma modifications of titanium using HMDSO are valuable candidates for future developments in anti-adhesive and anti-proliferative coatings for titanium fracture implants.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental materials and restorations · Facial Trauma and Fracture Management

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (35)

Show source-provided references
1. Ip WY, Ng KH, Chow SP. A prospective study of 924 digital fractures of the hand. Injury. 1996;27(4):279–85.10.1016/0020-1383(95)00222-7 ↗
2. Tay SC, Teoh LC. Soft tissue complications in Osteosynthesis. In: Herren DB, Nagy L, Campbell DA, editors. Osteosynthesis in the hand: current concepts. Basel: Karger; 2008. p. 135–41.
3. Lowry KJ, Gainor BJ, Hoskins JS. Extensor tendon rupture secondary to the AO/ASIF titanium distal radius plate without associated plate failure: a case report. Am J Orthop. 2000;29(10):789–91.
4. Ring D, Jupiter JB, Brennwald J, Buchler U, Hastings H II. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg [Am]. 1997;22(5):777–84.10.1016/S0363-5023(97)80069-X ↗
5. Richards RG. The relevance of implant surfaces in hand fracture fixation. Osteosynthesis in the hand: current concepts. Basel: Karger; 2008. p. 20–30.10.1159/000138577 ↗
6. Hayes JS, Richards RG. Surfaces to control tissue adhesion for osteosynthesis with metal implants: in vitro and in vivo studies to bring solutions to the patient. Expert Rev Med Devices. 2010;7(1):131–42. doi: 10.1586/erd.09.55 .10.1586/erd.09.55 ↗
7. Hayes JS, Seidenglanz U, Pearce AI, Pearce SG, Archer CW, Richards RG. Surface polishing positively influences ease of plate and screw removal. Eur Cell Mater. 2010;19:117–26.10.22203/eCM.v019a12 ↗
8. Meredith DO, Eschbach L, Riehle MO, Curtis ASG, Richards RG. Microtopography of metal surfaces influence fibroblast growth by modifying cell shape, cytoskeleton, and adhesion. J Orthop Res. 2007;25(11):1523–33. doi: 10.1002/jor.20430 .10.1002/jor.20430 ↗
9. Hayes JS, Welton JL, Wieling R, Richards RG. In vivo evaluation of defined polished titanium surfaces to prevent soft tissue adhesion. J Biomed Mater Res B. 2012;100(3):611–7.10.1002/jbm.b.31967 ↗
10. Forch R, Chifen AN, Bousquet A, Khor HL, Jungblut M, Chu LQ, et al. Recent and expected roles of plasma-polymerized films for biomedical applications. Chem Vap Depos. 2007;13(6–7):280–94. doi: 10.1002/cvde.200604035 .10.1002/cvde.200604035 ↗
11. Li DJ, Cui FZ, Gu HQ, Zhao J. Ion-beam-induced biomedical behavior of hexamethyldisiloxane films on deposited polyetherurethanes. Appl Surf Sci. 1998;126(1–2):1–10. doi: 10.1016/S0169-4332(97)00601-6 .
12. Pihan SA, Tsukruk T, Forch R. Plasma polymerized hexamethyl disiloxane in adhesion applications. Surf Coat Technol. 2009;203(13):1856–62. doi: 10.1016/J.Surfcoat.2009.01.026 .10.1016/j.surfcoat.2009.01.026 ↗
13. Hayakawa T, Yoshinari M, Nemoto K. Characterization and protein-adsorption behavior of deposited organic thin film onto titanium by plasma polymerization with hexamethyldisiloxane. Biomaterials. 2004;25(1):119–27.10.1016/S0142-9612(03)00484-8 ↗
14. Rebl H, Finke B, Lange R, Weltmann KD, Nebe JB. Impact of plasma chemistry versus titanium surface topography on osteoblast orientation. Acta Biomater. 2012;8(10):3840–51. doi: 10.1016/j.actbio.2012.06.015 .10.1016/j.actbio.2012.06.015 ↗
15. Aumaille K, Vallee C, Granier A, Goullet A, Gaboriau F, Turban G. A comparative study of oxygen/organosilicon plasmas and thin SiOxCyHz films deposited in a helicon reactor. Thin Solid Films. 2000;359(2):188–96.10.1016/S0040-6090(99)00883-4 ↗
16. Lin JC, Cooper SL. Surface characterization and ex vivo blood compatibility study of plasma-modified small diameter tubing: effect of sulphur dioxide and hexamethyldisiloxane plasmas. Biomaterials. 1995;16(13):1017–23.10.1016/0142-9612(95)94910-D ↗
17. Wei JH, Yoshinari M, Takemoto S, Hattori M, Kawada E, Liu BL, et al. Adhesion of mouse fibroblasts on hexamethyidisiloxane surfaces with wide range of wettability. J Biomed Mater Res B. 2007;81B(1):66–75. doi: 10.1002/jbm.b.30638 .10.1002/jbm.b.30638 ↗
18. Wei J, Igarashi T, Okumori N, Maetani T, Liu B, Yoshinari M. Influence of surface wettability on competitive protein adsorption and initial attachment of osteoblasts. Biomed Mater. 2009;4(4):045002. doi: 10.1088/1748-6041/4/4/045002 .10.1088/1748-6041/4/4/045002 ↗
19. Brendel C, Muller-Kuller U, Schultze-Strasser S, Stein S, Chen-Wichmann L, Krattenmacher A, et al. Physiological regulation of transgene expression by a lentiviral vector containing the A2UCOE linked to a myeloid promoter. Gene Ther. 2012;19(10):1018–29. doi: 10.1038/gt.2011.167 .10.1038/gt.2011.167 ↗
20. Goujon M, Belmonte I, Henrion G. OES and FTIR diagnostics of HMDSO/O2 gas mixtures for SiOx deposition assisted by RF plasma. Surf Coat Technol. 2004;188:756–61. doi: 10.1016/j.surfcoat.2004.07.048 .10.1016/j.surfcoat.2004.07.048 ↗
21. Chifen AN, Knoll W, Forch R. Fabrication of nano-porous silicon oxide layers by plasma polymerisation methods. Mater Lett. 2007;61(8–9):1722–4. doi: 10.1016/j.matlet.2006.07.118 .10.1016/j.matlet.2006.07.118 ↗
22. Yoshinari M, Hayakawa T, Matsuzaka K, Inoue T, Oda Y, Shimono M, et al. Oxygen plasma surface modification enhances immobilization of simvastatin acid. Biomed Res. 2006;27(1):29–36.10.2220/biomedres.27.29 ↗
23. Benitez F, Martinez E, Esteve J. Improvement of hardness in plasma polymerized hexamethyldisiloxane coatings by silica-like surface modification. Thin Solid Films. 2000;377:109–14. doi: 10.1016/s0040-6090(00)01393-6 .10.1016/S0040-6090(00)01393-6 ↗
24. Chifen AN, Jenkins ATA, Knoll W, Forch R. Adhesion improvement of plasma-polymerized maleic anhydride films on gold using HMDSO/O2 adhesion layers. Plasma Process Polym. 2007;4(9):815–22. doi: 10.1002/Ppap.200700012 .10.1002/ppap.200700012 ↗
25. Altankov G, Grinnell F, Groth T. Studies on the biocompatibility of materials: fibroblast reorganization of substratum-bound fibronectin on surfaces varying in wettability. J Biomed Mater Res. 1996;30(3):385–91.10.1002/(SICI)1097-4636(199603)30:3<385::AID-JBM13>3.0.CO;2-J ↗
26. Groth T, Altankov G. Studies on cell-biomaterial interaction role of tyrosine phosphorylation during fibroblast spreading on surfaces varying in wettability. Biomaterials. 1996;17(12):1227–34.10.1016/0142-9612(96)84943-X ↗
27. Benitez F, Martinez E, Esteve J, editors. Improvement of hardness in plasma polymerized hexamethyldisiloxane coatings by silica-like surface modification,April 10–14; San Diego, California;2000.
28. Hegemann D, Brunner H, Oehr C. Plasma treatment of polymers for surface and adhesion improvement. Nucl Instrum Methods Phys Res B. 2003;208:281–6. doi: 10.1016/S0168-583X(03)00644-X .10.1016/S0168-583X(03)00644-X ↗
29. Yoshinari M, Hayakawa T, Matsuzaka K, Inoue T, Oda Y, Shimono M. Immobilization of fibronectin onto organic hexamethyldisiloxane coating with plasma surface modification. J Oral Tissue Eng. 2004;1(1):69–79.
30. Schroder K, Finke B, Ohl A, Luthen F, Bergemann C, Nebe B, et al. Capability of differently charged plasma polymer coatings for control of tissue interactions with titanium surfaces. J Adhes Sci Technol. 2010;24(7):1191–205. doi: 10.1163/016942409x12619870771501 .10.1163/016942409X12619870771501 ↗
31. Kasemo B. Biocompatibility of titanium implants: surface science aspects. J Prosthet Dent. 1983;49(6):832–7.10.1016/0022-3913(83)90359-1 ↗
32. Folkman J, Moscona A. Role of cell shape in growth control. Nature. 1978;273(5661):345–9.10.1038/273345a0 ↗
33. Hayes JS, Vos DI, Hahn J, Pearce SG, Richards RG. An in vivo evaluation of surface polishing of TAN intermedullary nails for ease of removal. Eur Cell Mater. 2009;18:15–26.10.22203/eCM.v018a02 ↗
34. Pearce AI, Pearce SG, Schwieger K, Milz S, Schneider E, Archer CW, et al. Effect of surface topography on removal of cortical bone screws in a novel sheep model. J Orthop Res. 2008;26(10):1377–83. doi: 10.1002/jor.20665 .10.1002/jor.20665 ↗
35. Pearce AI, Richards RG, Milz S, Schneider E, Pearce SG. Animal models for implant biomaterial research in bone: a review. Eur Cell Mater. 2007;13:1–10.10.22203/eCM.v013a01 ↗