journal article·2022-04Open access

Corrosion, mechanical and bioactivity properties of HA-CNT nanocomposite coating on anodized Ti6Al4V alloy

Faezeh Dalili, Rouhollah Mehdinavaz Aghdam, Reza Soltani, Mohsen Saremi

Abstract

Abstract Hydroxyapatite-carbon nanotubes (HA-CNTs) nanocomposite coating was applied by electrophoretic method on anodized Ti alloy to investigate its stability in simulated body fluid (SBF). The biocoating was characterized by using scanning electron microscope (SEM) for microstructure, X-ray diffraction (XRD) for crystallography. The effect of CNTs concentration on the coating properties was also investigated and found out that CNTs up to 5% has various improving effect on the system. It increased corrosion resistance and adhesion of the coating to the substrate and decreased the number of cracks on the coating. The results of the in vitro test showed that the cell viability increased with increasing the concentration of CNTs to 3 wt.% CNTs.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Electrophoretic Deposition in Materials Science · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Williams DF. On the mechanisms of biocompatibility. Biomaterials. 2008;29:2941–53.10.1016/j.biomaterials.2008.04.023 ↗
2. Ducheyne P, Van Raemdonck W, Heughebaert JC, Heughebaert M. Structural analysis of hydroxyapatite coatings on titanium. Biomaterials. 1986;7:97–103.10.1016/0142-9612(86)90063-3 ↗
3. Zhitomirsky I, Gal-Or L. Electrophoretic deposition of hydroxyapatite. J Mater Sci. 1997;8:213–9.
4. Gomez-Vega JM, Saiz E, Tomsia AP, Marshall GW, Marshall SJ. Bioactive glass coatings with hydroxyapatite and Bioglass® particles on Ti-based implants. 1. Processing Biomater. 2000;21:105–11.10.1016/S0142-9612(99)00131-3 ↗
5. Wang C, et al. Phenotypic expression of bone-related genes in osteoblasts grown on calcium phosphate ceramics with different phase compositions. Biomaterials. 2004;25:2507–14.10.1016/j.biomaterials.2003.09.035 ↗
6. Balani K, Chen Y, Harimkar SP, Dahotre NB, Agarwal A. Tribological behavior of plasma-sprayed carbon nanotube-reinforced hydroxyapatite coating in physiological solution. Acta Biomaterialia. 2007;3:944–51.10.1016/j.actbio.2007.06.001 ↗
7. Yu LG, Khor KA, Li H, Cheang P. Effect of spark plasma sintering on the microstructure and in vitro behavior of plasma sprayed HA coatings. Biomaterials. 2003;24:2695–705.10.1016/S0142-9612(03)00082-6 ↗
8. Gu YW, Khor KA, Cheang P. Bone-like apatite layer formation on hydroxyapatite prepared by spark plasma sintering (SPS). Biomaterials. 2004;25:4127–34.10.1016/j.biomaterials.2003.11.030 ↗
9. Xiao XF, Liu RF, Zheng YZ. Characterization of hydroxyapatite/titania composite coatings codeposited by a hydrothermal–electrochemical method on titanium. Surf Coat Technol. 2006;200:4406–13.10.1016/j.surfcoat.2005.02.205 ↗
10. Rahimi M, et al. Improving biocompatibility and corrosion resistance of anodized AZ31 Mg alloy by electrospun chitosan/mineralized bone allograft (MBA) nanocoatings. Surf Coat Technol. 2021;405:126627.10.1016/j.surfcoat.2020.126627 ↗
11. Li M, et al. An overview of graphene-based hydroxyapatite composites for orthopedic applications. Bioact Mater. 2018;3:1–18.10.1016/j.bioactmat.2018.01.001 ↗
12. Janković A, et al. Bioactive hydroxyapatite/graphene composite coating and its corrosion stability in simulated body fluid. J Alloy Compd. 2015;624:148–57.10.1016/j.jallcom.2014.11.078 ↗
13. Li M, et al. Graphene oxide/hydroxyapatite composite coatings fabricated by electrophoretic nanotechnology for biological applications. Carbon. 2014;67:185–97.10.1016/j.carbon.2013.09.080 ↗
14. Gopi D, Shinyjoy E, Madhu S, Surendiran M, Louis K, Kumar TS. Development of carbon nanotubes reinforced hydroxapatite composite coatings on titanium by electrodeposition method. Corros Sci. 2013;73:321–30.10.1016/j.corsci.2013.04.021 ↗
15. Pang X, Zhitomirsky I. Electrodeposition of composite hydroxyapatite–chitosan films. Mater Chem Phys. 2005;94:245–51.10.1016/j.matchemphys.2005.04.040 ↗
16. Kwok CT, Wong PK, Cheng FT, Man HC. Characterization and corrosion behavior of hydroxyapatite coatings on Ti6Al4V fabricated by electrophoretic deposition. Appl Surf Sci. 2009;255:6736–44.10.1016/j.apsusc.2009.02.086 ↗
17. Kaya C. Electrophoretic deposition of carbon nanotube-reinforced hydroxyapatite bioactive layers on Ti–6Al–4V alloys for biomedical applications. Ceram Int. 2008;34:1843–7.10.1016/j.ceramint.2007.06.007 ↗
18. Khazeni D, Saremi M, Soltani R. Development of HA-CNTs composite coating on AZ31 magnesium alloy by cathodic electrodeposition. Part 1: Microstructural and mechanical characterization. Ceram Int. 2019;45:11174–85.10.1016/j.ceramint.2019.02.143 ↗
19. Askari N, Yousefpour M, Rajabi M. Electrochemical and biological characterization HA/Al2O3-YSZ nano-composite coatings using electrophoretic process. J Biomed Mater Res Part A. 2018;106:1916–22. https://doi.org/10.1002/jbm.a.36392.10.1002/jbm.a.36392 ↗
20. Kim H-W, Koh Y-H, Li L-H, Lee S, Kim H-E. Hydroxyapatite coating on titanium substrate with titania buffer layer processed by sol–gel method. Biomaterials. 2004;25:2533–8.10.1016/j.biomaterials.2003.09.041 ↗
21. Ji H, Marquis PM. Effect of heat treatment on the microstructure of plasma-sprayed hydroxyapatite coating. Biomaterials. 1993;14:64–68.10.1016/0142-9612(93)90077-F ↗
22. Besra L, Liu M. A review on fundamentals and applications of electrophoretic deposition (EPD). Prog Mater Sci. 2007;52:1–61.10.1016/j.pmatsci.2006.07.001 ↗
23. Kokubo T, Takadama H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials. 2006;27:2907–15.10.1016/j.biomaterials.2006.01.017 ↗
24. Golafshan N, Kharaziha M, Fathi M. Tough and conductive hybrid graphene-PVA: Alginate fibrous scaffolds for engineering neural construct. Carbon. 2017;111:752–63.10.1016/j.carbon.2016.10.042 ↗
25. Karimi N, Kharaziha M, Raeissi K. Electrophoretic deposition of chitosan reinforced graphene oxide-hydroxyapatite on the anodized titanium to improve biological and electrochemical characteristics. Mater Sci Eng: C. 2019;98:140–52.10.1016/j.msec.2018.12.136 ↗
26. L Salou, A Hoornaert, G Louarn, and P Layrolle, Bone apposition on nanoporous titanium implants, 2015, pp. 427–444.10.1016/B978-0-12-799947-0.00020-1 ↗
27. Amirsardari Z, et al. Facile Carbothermal Reduction Synthesis of ZrB2 Nanoparticles: The Effect of Starting Precursors. Materials and Manufacturing Processes. 2016;31:2:134–40.10.1080/10426914.2015.1019119 ↗
28. Xie Z, Blackwood D. Effects of anodization parameters on the formation of titania nanotubes in ethylene glycol. Electrochim Acta. 2010;56:905–12.10.1016/j.electacta.2010.10.004 ↗
29. X Zhang, D Zhang, Q Peng, J Lin, and C Wen, Biocompatibility of nanoscale hydroxyapatite coating on TiO(2) nanotubes, (in eng), Materials., 2019;12:1–12.10.3390/ma12121979 ↗
30. Parcharoen Y, Kajitvichyanukul P, Sirivisoot S, Termsuksawad P. Hydroxyapatite electrodeposition on anodized titanium nanotubes for orthopedic applications. Appl Surf Sci. 2014;311:54–61.10.1016/j.apsusc.2014.04.207 ↗
31. Khanmohammadi S, Ojaghi-Ilkhchi M, Farrokhi-Rad M. Development of bioglass coating reinforced with hydroxyapatite whiskers on TiO2 nanotubes via electrophoretic deposition. Ceram Int. 2021;47:1333–43.10.1016/j.ceramint.2020.08.255 ↗
32. Piszczek P, et al. Biocompatibility of titania nanotube coatings enriched with silver nanograins by chemical vapor deposition. Nanomaterials. 2017;7:274.10.3390/nano7090274 ↗
33. Khudhair D, et al. Anodization parameters influencing the morphology and electrical properties of TiO2 nanotubes for living cell interfacing and investigations. Mater Sci Eng: C. 2016;59:1125–42.10.1016/j.msec.2015.10.042 ↗
34. W-T Kim and W-Y Choi, Anodic growth behavior of TiO2 nanotube arrays with process parameter control, J Nanomater, 2019; 2019:8293427.10.1155/2019/8293427 ↗
35. Qadir M, Li Y, Biesiekierski A, Wen C. Surface characterization and biocompatibility of hydroxyapatite coating on anodized TiO2 nanotubes via PVD magnetron sputtering. Langmuir. 2021;37:4984–96.10.1021/acs.langmuir.1c00411 ↗
36. Zhang S, Li Y, Xu P, Liang K. Effect of anodization parameters on the surface morphology and photoelectrochemical properties of TiO2 nanotubes. Int J Electrochem Sci. 2017;12:10714–25.10.20964/2017.11.80 ↗
37. Tavakkoli-Gilavan M, Abdizadeh H, Golobostanfard MR. Biomineralization behavior of electrophoretic-deposited hydroxyapatite-tricalcalcium phosphate biphasic composite. Appl Surf Sci. 2018;458:988–95.10.1016/j.apsusc.2018.07.168 ↗
38. Zhitomirsky I. Electrophoretic hydroxyapatite coatings and fibers. Mater Lett. 2000;42:262–71.10.1016/S0167-577X(99)00197-4 ↗
39. Berry C, Campbell G, Spadaccino A, Robertson M, Curtis A. The influence of microscale topography on fibroblast attachment and motility. Biomaterials. 2004;25:5781–8.10.1016/j.biomaterials.2004.01.029 ↗
40. Lahiri D, Ghosh S, Agarwal A. Carbon nanotube reinforced hydroxyapatite composite for orthopedic application: a review. Mater Sci Eng: C. 2012;32:1727–58.10.1016/j.msec.2012.05.010 ↗
41. Hahn B-D, et al. Mechanical and in vitro biological performances of hydroxyapatite–carbon nanotube composite coatings deposited on Ti by aerosol deposition. Acta Biomaterialia. 2009;5:3205–14.10.1016/j.actbio.2009.05.005 ↗
42. Munirathinam B, Pydimukkala H, Ramaswamy N, Neelakantan L. Influence of crystallite size and surface morphology on electrochemical properties of annealed TiO2 nanotubes. Appl Surf Sci. 2015;355:1245–53.10.1016/j.apsusc.2015.08.017 ↗
43. Hodgson AWE, Mueller Y, Forster D, Virtanen S. Electrochemical characterisation of passive films on Ti alloys under simulated biological conditions. Electrochim Acta. 2002;47:1913–23.10.1016/S0013-4686(02)00029-4 ↗
44. Hamlekhan A, et al. Fabrication of anti-aging TiO2 nanotubes on biomedical Ti alloys, (in eng). PLoS One. 2014;9:e96213.10.1371/journal.pone.0096213 ↗
45. Ahmadi S, Mohammadi I, Sadrnezhaad SK. Hydroxyapatite based and anodic Titania nanotube biocomposite coatings: Fabrication, characterization and electrochemical behavior. Surf Coat Technol. 2016;287:67–75.10.1016/j.surfcoat.2015.12.062 ↗
46. Batmanghelich F, Ghorbani M. Effect of pH and carbon nanotube content on the corrosion behavior of electrophoretically deposited chitosan–hydroxyapatite–carbon nanotube composite coatings. Ceram Int. 2013;39:5393–402.10.1016/j.ceramint.2012.12.046 ↗
47. Ghelich R, et al. Low Temperature Carbothermal Reduction Synthesis of ZrC Nanofibers via Cyclized Electrospun PVP/Zr(OPr)4 Hybrid. Int. J. Appl. Ceram. Technol. 2015;13:352–8.10.1111/ijac.12475 ↗
48. Amirsardari Z, et al. Preparation and characterization of nanoscale ZrB2/carbon–resol composite for protection against high-temperature corrosion. J Therm Anal Calorim. 2015;120:1535–41.10.1007/s10973-015-4474-7 ↗
49. Mutlu GkM, et al. Biocompatible nanoscale dispersion of single-walled carbon nanotubes minimizes in vivo pulmonary toxicity. Nano Lett. 2010;10:1664–70.10.1021/nl9042483 ↗
50. Xu JL, Khor KA, Sui JJ, Chen WN. Preparation and characterization of a novel hydroxyapatite/carbon nanotubes composite and its interaction with osteoblast-like cells. Mater Sci Eng: C. 2009;29:44–49.10.1016/j.msec.2008.05.009 ↗
51. Vahedi S, et al. Carbon nanotubes reinforced electrospun chitosan nanocomposite coating on anodized AZ31 magnesium alloy. J Ultrafine Graine Nanostruct Mater. 2020;53:71–77.
52. Lin C, Han H, Zhang F, Li A. Electrophoretic deposition of HA/MWNTs composite coating for biomaterial applications. J Mater Sci: Mater Med. 2008;19:2569–74.
53. Kalmodia S, Goenka S, Laha T, Lahiri D, Basu B, Balani K. Microstructure, mechanical properties, and in vitro biocompatibility of spark plasma sintered hydroxyapatite–aluminum oxide–carbon nanotube composite. Mater Sci Eng: C. 2010;30:1162–9.10.1016/j.msec.2010.06.009 ↗
54. Guo Y-P, Yao Y-b, Ning C-Q, Chu L-F, Guo Y-J. Fabrication of mesoporous carbonated hydroxyapatite/carbon nanotube composite coatings by microwave irradiation method. Mater Lett. 2011;65:1007–9.10.1016/j.matlet.2010.12.036 ↗