journal article·2012-11

Overcoming hypoxia in 3D culture systems for tissue engineering of bone in vitro using an automated, oxygen-triggered feedback loop

Elias Volkmer, Sven Otto, Hans Polzer, Maximilian Saller, Daniel Trappendreher, Darin Zagar, Sabine Hamisch, Günter Ziegler, Arndt Wilhelmi, Wolf Mutschler, Matthias Schieker

Publisher page

Abstract

Tissue engineering is an attractive approach to heal bony defects. However, three-dimensional cell-scaffold constructs display uneven oxygen supply resulting in inhomogeneous tissue quality. We assessed different strategies to improve oxygen supply in vitro. Scaffolds with differing inner surface were seeded with preosteoblastic cells and cultivated either statically or in perfusion bioreactors. Oxygen concentration and pH were measured in the center of the scaffolds. An inductive feedback mechanism was build to increase bioreactor pump speed according to the oxygen concentrations measured within the scaffolds. While pH remained stable, oxygen concentration decreased significantly under static conditions within the cell-seeded scaffolds. Reducing the scaffolds' inner surface as well as increasing perfusion speeds in bioreactors resulted in improved oxygen supply. We conclude that improving oxygen supply to three dimensional culture systems for bone tissue engineering is feasible in an automated manner. Culture conditions have to be adapted to each cell-scaffold system individually.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: 3D Printing in Biomedical Research · Bone Tissue Engineering Materials · Mesenchymal stem cell research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (20)

Show source-provided references
1. Schieker M, Heiss C, Mutschler W. Bone substitutes. Unfallchirurg. 2008;111(8):613–9.10.1007/s00113-008-1489-6 ↗
2. Drosse I, et al. Tissue engineering for bone defect healing: an update on a multi-component approach. Injury. 2008;39(Suppl 2):S9–20.10.1016/S0020-1383(08)70011-1 ↗
3. Vacanti CA, Bonassar LJ, Vacanti MP, Shufflebarger J. Replacement of an avulsed phalanx with tissue-engineered bone. N Engl J Med. 2001;344(20): 1511–14, 17–5.
4. Levin LS. Vascularized fibula graft for the traumatically induced long-bone defect. J Am Acad Orthop Surg. 2006;14(10 Spec No.):S175–6.10.5435/00124635-200600001-00038 ↗
5. Heiss C, Schieker M, Schnettler R. Implantation of bone substitutes for tibial head fractures. Unfallchirurg. 2008;111(8):621–7.10.1007/s00113-008-1463-3 ↗
6. Seitz S, et al. Influence of in vitro cultivation on the integration of cell-matrix constructs after subcutaneous implantation. Tissue Eng. 2007;13(5):1059–67.10.1089/ten.2006.0334 ↗
7. Volkmer E, et al. Hypoxia in static and dynamic 3D culture systems for tissue engineering of bone. Tissue Eng Part A. 2008;14(8):1331–40.10.1089/ten.tea.2007.0231 ↗
8. Volkmer E, et al. Hypoxic preconditioning of human mesenchymal stem cells overcomes hypoxia-induced inhibition of osteogenic differentiation. Tissue Eng Part A. 2010;16(1):153–64.10.1089/ten.tea.2009.0021 ↗
9. Carrier RL, et al. Effects of oxygen on engineered cardiac muscle. Biotechnol Bioeng. 2002;78(6):617–25.10.1002/bit.10245 ↗
10. McClelland RE, Coger RN. Use of micropathways to improve oxygen transport in a hepatic system. J Biomech Eng. 2000;122(3):268–73.10.1115/1.429657 ↗
11. Arkudas A, et al. Axial prevascularization of porous matrices using an arteriovenous loop promotes survival and differentiation of transplanted autologous osteoblasts. Tissue Eng. 2007;13(7):1549–60.10.1089/ten.2006.0387 ↗
12. Mylotte LA, et al. Metabolic flexibility permits mesenchymal stem cell survival in an ischemic environment. Stem Cells. 2008;26(5):1325–36.10.1634/stemcells.2007-1072 ↗
13. Boker W, et al. Introducing a single-cell-derived human mesenchymal stem cell line expressing hTERT after lentiviral gene transfer. J Cell Mol Med. 2008;12(4):1347–59.10.1111/j.1582-4934.2008.00299.x ↗
14. Detsch R, Uhl F, Deisinger U, Ziegler G. 3D-Cultivation of bone marrow stromal cells on hydroxyapatite scaffolds fabricated by dispense-plotting and negative mould technique. J Mater Sci Mater Med. 2008;19(4):1491–6.10.1007/s10856-007-3297-x ↗
15. Malda J, Klein TJ, Upton Z. The roles of hypoxia in the in vitro engineering of tissues. Tissue Eng. 2007;13(9):2153–62.10.1089/ten.2006.0417 ↗
16. Malladi P, Xu Y, Chiou M, Giaccia AJ, Longaker MT. Effect of reduced oxygen tension on chondrogenesis and osteogenesis in adipose-derived mesenchymal cells. Am J Physiol Cell Physiol. 2006;290(4):C1139–46.10.1152/ajpcell.00415.2005 ↗
17. Ye H, Xia Z, Ferguson DJ, Triffitt JT, Cui Z. Studies on the use of hollow fibre membrane bioreactors for tissue generation by using rat bone marrow fibroblastic cells and a composite scaffold. J Mater Sci Mater Med. 2007;18(4):641–8.10.1007/s10856-007-2314-4 ↗
18. Jee WSS. The skeletal tissues. In: Weiss L, editor. Histology: cell and tissue biology. 5th ed. Baltimore: Urban and Schwartzenberg; 1983. p. 206–54.
19. Singh H, Ang ES, Lim TT, Hutmacher DW. Flow modeling in a novel non-perfusion conical bioreactor. Biotechnol Bioeng. 2007;97(5):1291–9.10.1002/bit.21327 ↗
20. Sikavitsas VI, et al. Flow perfusion enhances the calcified matrix deposition of marrow stromal cells in biodegradable nonwoven fiber mesh scaffolds. Ann Biomed Eng. 2005;33(1):63–70.10.1007/s10439-005-8963-x ↗