journal article·2014-09Open access

Correlation between in vivo stresses and oxidation of UHMWPE in total hip arthroplasty

M. Regis, P. Bracco, L. Giorgini, S. Fusi, P. Dalla Pria, L. Costa, C. Schmid

Abstract

The possibility of in vivo, stress-induced oxidation in orthopaedic UHMWPE has been investigated. EtO sterilised, uncrosslinked UHMWPE liners, explanted or shelf-aged, have been collected. Linear wear and wear rate were assessed and FTIR spectroscopy was employed to detect oxidation and to build up oxidation products spatial maps across the liners section. Oxidation profiles have been compared to stress distribution profiles, resulting from a FE analysis conducted on the same liners geometries and couplings. It was found that oxidised and stressed areas followed the same asymmetrical, localized distribution profile. It was therefore possible to establish a correlation between stressed areas and observed oxidation.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Advanced materials and composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (38)

Show source-provided references
1. Kurtz SM, Muratoglu OK, Evans M, Edidin AA. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials. 1999;20:1659–88.10.1016/S0142-9612(99)00053-8 ↗
2. Kurtz SM. The UHMWPE biomaterials handbook. 2nd ed. Burlington: Elsevier; 2009.
3. Kurtz SM, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg Am. 2007;89:780–5.10.2106/JBJS.F.00222 ↗
4. Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic K. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res. 2009;467:2606–12.10.1007/s11999-009-0834-6 ↗
5. Willert HG, Bertram H, Buchhorn HG. Osteolysis in alloarthroplasty of the hip. The role of ultra high molecular weight polyethylene wear particles. Clin Orthop. 1990;258:95–107.
6. Costa L, Luda MP, Trossarelli L. Ultra-high molecular weight polyethylene: mechano-oxidative degradation. Polym Degrad Stab. 1997;55:329–38.10.1016/S0141-3910(96)00170-X ↗
7. Bracco P, Oral E. Vitamin E-stabilized UHMWPE for total joint implants:a review. Clin Orthop Relat Res. 2011;469:2286–93.10.1007/s11999-010-1717-6 ↗
8. Mc Kellop H, Shen FW, Lu B, Campbell F, Salovey R. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra high molecular weight polyethylene: a hip-simulator study. J Bone Joint Surg Am. 2000;82:1708–25.10.2106/00004623-200012000-00004 ↗
9. Costa L, Bracco P, Brach del Prever EM, Kurtz SM, Gallinaro P. Oxidation and oxidation potential in contemporary packaging for UHMWPE total joint replacement components. J Biomed Mater Res Appl B. 2006;78(1):20–6.10.1002/jbm.b.30454 ↗
10. Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gllinaro P. Oxidation in orthopaedic UHMWPE sterilized by gamma and EtO. Biomaterials. 1998;19:659–68.10.1016/S0142-9612(97)00160-9 ↗
11. Bohl JR, Bohl WR, Postak PD, Greenwald AS. The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components. Clin Orthop Relat Res. 1999;367:28–38.
12. Walsh HA, Furman BD, Naab S, Li S. Role of oxidation in the clinical fracture of acetabular cups. Trans ORS. 1999;45:845.
13. Medel FJ, Kurtz SM, Parvizi J, Klein JR, Kraay MJ, Rimnac CM. In vivo oxidation contributes to delamination but not pitting in polyethylene components for total knee arthroplasty. J Arthtrop. 2011;26:802–10.10.1016/j.arth.2010.07.010 ↗
14. Costa L, Luda MP, Trossarelli L, Brach del Prever EM, Crova M, Gallinaro P. In vivo UHMWPE biodegradation of retrieved prosthesis. Biomaterials. 1998;19:1371–85.10.1016/S0142-9612(98)00013-1 ↗
15. Brach del Prever EM, Bistolfi A, Bracco P, Costa L. UHMWPE for arthroplasy: past or future? J Orthop Traumatol. 2009;10:1–8.10.1007/s10195-008-0038-y ↗
16. Baker DA, Bellare A, Pruitt L. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res A. 2003;66:146–54.10.1002/jbm.a.10606 ↗
17. Avanzini A. Mechanical characterization and finite element modeling of cyclic stress–strain behaviour of ultra high molecular weight polyethylene. Mater Des. 2008;29:330–43.10.1016/j.matdes.2007.01.031 ↗
18. Lacoste J, Carlsson DJ. Gamma, photo and thermally-initiated oxidation of linear low-density polyethylene: a quantitative comparison of oxidation products. J Polym Sci A. 1992;30:493–500.10.1002/pola.1992.080300316 ↗
19. Igarashi M. Free radical identification by ESR in polyethylene and nylon. J Polym Sci A. 1983;21:2405–25.
20. Arnaud R, Mosain JY, Lemarie J. Primary hydroperoxidation in low density polyethylene. Macromolecules. 1984;17:332–6.10.1021/ma00133a012 ↗
21. Costa L, Brach del Prever EM. UHMWPE for arthroplasty, vol. 1. Turin: Minerva Medica; 2000.
22. Oral E, Christensen SD, Malhi AS, Wannomae KK, Muratoglu OK. Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E. J Arthrop. 2006;21:580–91.10.1016/j.arth.2005.07.009 ↗
23. Brach del Prever EM, Costa L, Crova M, Dallera A, Camino G, Gallinaro P. Unacceptable biodegradation of polyethylene in vivo. Biomaterials. 1996;17:873–8.10.1016/0142-9612(96)83282-0 ↗
24. Costa L, Jacobson K, Bracco P, Brach del Prever EM. Oxidation of orthopaedic UHMWPE. Biomaterials. 2002;23:1613–24.10.1016/S0142-9612(01)00288-5 ↗
25. Costa L, Jacobson K, Bracco P, Brach del Prever EM. Erratum to “Oxidation of orthopaedic UHMWPE” [Biomaterials 23 (2002) 1613–1624]. Biomaterials. 2005;26:347–8.
26. Costa L, Luda MP, Trossarelli L. Ultra-high molecular weight polyethylene: thermal and foto oxidation. Polym Degrad Stab. 1997;58:41–54.10.1016/S0141-3910(97)00010-4 ↗
27. Costa L, Bracco P, Brach del Prever EM, Luda MP. Oxidation and stabilization of orthopedic UHMWPE, vol. 1., UHMWPE for arthroplasty: from synthesis to implantTurin: Università degli studi di Torino; 2005.
28. Currier BH, Van Citters DW, Currier JH, Carlson EM, Tibbo ME, Collier JP. In vivo oxidation in retrieved highly crosslinked tibial inserts. J Biomed Mater Res B. 2013;101B:441–8.10.1002/jbm.b.32805 ↗
29. Oral E, Ghali B, Neils A, Muratoglu O. A new mechanism of oxidation in UHMWPE caused by squalene absorption. J Biomed Mater Res B. 2012;100:742–51.10.1002/jbm.b.32507 ↗
30. Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990;72:518–28.10.2106/00004623-199072040-00008 ↗
31. Costa L, Carpentieri I, Bracco P. Post electron beam irradiation oxidation of orthopaedic UHMWPE. Polym Degrad Stab. 2008;93:1695–703.10.1016/j.polymdegradstab.2008.06.003 ↗
32. Costa L, Jacobson K, Brunella V, Bracco P. Effects of microtomy on the material properties of ultra-high molecular weight polyethylene. Polym Test. 2001;20:649–59.10.1016/S0142-9418(00)00088-X ↗
33. Bergmann G, Deuretzbacher G, Heller M, Graichen F, Rohlmann A, Strauss J, Duda GN. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34:859–71.10.1016/S0021-9290(01)00040-9 ↗
34. Taylor M, Barrett DS. Explicit finite element simulation of eccentric loading in total knee replacement. Clin Orthop Relat Res. 2003;414:162–71.10.1097/01.blo.0000079267.91782.58 ↗
35. Bergstrom JS, Rimnac CM, Kurtz SM. An augmented hybrid constitutive model for simulation of unloading and cyclic loading behavior of conventional and highly crosslinked UHMWPE. Biomaterials. 2004;25:2171–8.10.1016/j.biomaterials.2003.08.065 ↗
36. Furmanski J, Pruitt LA. Peak stress intensity dictates fatigue crack propagation in UHMWPE. Polymer. 2007;48:3512–9.10.1016/j.polymer.2007.04.006 ↗
37. Goebel P, Kluess D, Wieding J, Souffrant R, Heyer H, Sander M, Bader R. The influence of head diameter and wall thickness on deformations of metallic acetabular press-fit cups and UHMWPE liners: a finite element analysis. J Orthop Sci. 2013;18:264–70.10.1007/s00776-012-0340-7 ↗
38. Mac Donald D, Hanzlik J, Sharkey P, Parvizi J, Kurtz SM. In vivo oxidation and surface damage in retrieved ethylene-oxide sterilized total knee arthroplasties. Clin Orthop Relat Res. 2012;470:1826–33.10.1007/s11999-011-2184-4 ↗