journal article·2023-05-25Open access

Impacts of residual 3D printing metal powders on immunological response and bone regeneration: an in vivo study

Jincheng Tang, Zhuo Sang, Xiaolei Zhang, Changhui Song, Wei Tang, Xiaoping Luo, Ming Yan

Abstract

Abstract Residual powder is a defect in powder bed fusion-based additive manufacturing (3D printing), and it is difficult to completely remove it from as-printed materials. In addition, it is not necessary to apply 3D printed implants with residual powder in the clinic. The immunological response triggered by the residual powder is an important area of study in medical research. To further understand the possible immunological reactions and hidden dangers caused by residual powders in vivo, this study compared the immunological reactions and osteolysis caused by typical powders for four implant materials: 316 L stainless steel, CoCrMo, CP-Ti, and Ti-6Al-4V (particle size range of 15–45 μm), in a mouse skull model. Furthermore, the possible immunological responses and bone regeneration induced by the four 3D printed implants with residual powder in a rat femur model were compared. In the mouse skull model, it was found that the 316L-S, CoCrMo-S, and especially the 316L-M powders, upregulated the expression of pro-inflammatory factors, increased the ratio of RANKL/OPG, and activated more functional osteoclasts, resulting in more severe bone resorption compared with those in other groups. In the rat femur model, which is more suitable for clinical practice, there is no bone resorption in implants with residual powders, but they show good bone regeneration and integration ability because of their original roughness. The results indicate that the expressions of inflammatory cytokines in all experimental groups were the same as those in the control group, showing good biological safety. The results answered some critical questions related to additively manufactured medical materials in vivo and indicated that as-printed implants may have great potential in future clinical applications. Graphical Abstract
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (55)

Show source-provided references
1. Ali S, Rani AMA, Baig Z, Ahmed SW, Hussain G, Subramaniam K, et al. Biocompatibility and corrosion resistance of metallic biomaterials. Corros Rev. 2020;38:381–402.10.1515/corrrev-2020-0001 ↗
2. Chen QZ, Thouas GA. Metallic implant biomaterials. Mat Sci Eng R 2015;87:1–57.10.1016/j.mser.2014.10.001 ↗
3. Li J, Cui XL, Hooper GJ, Lim KS, Woodfield TBF. Rational design, bio-functionalization and biological performance of hybrid additive manufactured titanium implants for orthopaedic applications: a review. J Mech Behav Biomed. 2020;105:103671.10.1016/j.jmbbm.2020.103671 ↗
4. Wei Q, Li S, Han C, Li W, Cheng L, Hao L, et al. Selective laser melting of stainless-steel/nano-hydroxyapatite composites for medical applications: microstructure, element distribution, crack and mechanical properties. J Mater Process Tech. 2015;222:444–53.10.1016/j.jmatprotec.2015.02.010 ↗
5. Blackwood DJ. Biomaterials: past successes and future problems. Corros Rev. 2003;21:97–24.10.1515/CORRREV.2003.21.2-3.97 ↗
6. Aslan N, Aksakal B, Findik F. Fabrication of porous-Ti6Al4V alloy by using hot pressing technique and Mg space holder for hard-tissue biomedical applications. J Mater Sci Mater Med. 2021;32:80.10.1007/s10856-021-06546-2 ↗
7. Rack HJ, Qazi JI. Titanium alloys for biomedical applications. Mat Sci Eng C-Mater. 2006;26:1269–77.10.1016/j.msec.2005.08.032 ↗
8. Lowther M, Louth S, Davey A, Hussain A, Ginestra P, Carter L, et al. Clinical, industrial, and research perspectives on powder bed fusion additively manufactured metal implants. Addit Manuf. 2019;28:565–84.
9. Dong YP, Tang JC, Wang DW, Wang N, He ZD, Li J, et al. Additive manufacturing of pure Ti with superior mechanical performance, low cost, and biocompatibility for potential replacement of Ti-6Al-4V. Mater Des. 2020;196:109142.10.1016/j.matdes.2020.109142 ↗
10. Liu BC, Hou GJ, Yang ZW, Li XC, Zheng YF, Wen P, et al. Repair of critical diaphyseal defects of lower limbs by 3D printed porous Ti6Al4V scaffolds without additional bone grafting: a prospective clinical study. J Mater Sci Mater Med. 2022;33:64.10.1007/s10856-022-06685-0 ↗
11. Zhou YH, Zhang ZH, Wang YP, Liu G, Zhou SY, Li YL, et al. Selective laser melting of typical metallic materials: an effective process prediction model developed by energy absorption and consumption analysis. Addit Manuf. 2019;25:204–17.
12. Luo JP, Sun JF, Huang YJ, Zhang JH, Zhang YD, Zhao DP, et al. Low-modulus biomedical Ti–30Nb–5Ta–3Zr additively manufactured by selective laser melting and its biocompatibility. Mat Sci Eng C-Mater. 2019;97:275–84.10.1016/j.msec.2018.11.077 ↗
13. Yang L, Yan CZ, Cao WC, Liu ZF, Song B, Wen SF, et al. Compression-compression fatigue behaviour of gyroid-type triply periodic minimal surface porous structures fabricated by selective laser melting. Acta Mater. 2019;181:49–66.10.1016/j.actamat.2019.09.042 ↗
14. Zhou X, Li KL, Zhang DD, Liu XH, Ma J, Liu W, et al. Textures formed in a CoCrMo alloy by selective laser melting. J Alloy Compd. 2015;631:153–64.10.1016/j.jallcom.2015.01.096 ↗
15. Gong H, Rafi K, Gu H, Starr T, Stucker B. Analysis of defect generation in Ti–6Al–4V parts made using powder bed fusion additive manufacturing processes. Addit Manuf. 2014;1-4:87–98.
16. Andani MT, Dehghani R, Karamooz-Ravari MR, Mirzaeifar R, Ni J. A study on the effect of energy input on spatter particles creation during selective laser melting process. Addit Manuf. 2018;20:33–43.
17. Liang XL, Liu ZQ, Liu WT, Wang B, Yao GH. Surface integrity analysis for high-pressure jet assisted machined Ti-6Al-4V considering cooling pressures and injection positions. J Manuf Process. 2019;40:149–59.10.1016/j.jmapro.2019.03.020 ↗
18. Wysocki B, Idaszek J, Buhagiar J, Szlazak K, Brynk T, Kurzydlowski KJ, et al. The influence of chemical polishing of titanium scaffolds on their mechanical strength and in-vitro cell response. Mat Sci Eng C-Mater. 2019;95:428–39.10.1016/j.msec.2018.04.019 ↗
19. Zhang BQ, Pei X, Zhou CC, Fan YJ, Jiang Q, Ronca A, et al. The biomimetic design and 3D printing of customized mechanical properties porous Ti6Al4V scaffold for load-bearing bone reconstruction. Mater Des. 2018;152:30–39.10.1016/j.matdes.2018.04.065 ↗
20. Bao W, He Y, Fan YJ, Liao YM. Metal allergy in total-joint arthroplasty case report and literature review. Medicine 2018;97:38.10.1097/MD.0000000000009015 ↗
21. Campbell RM, Smith MD. Thoracic insufficiency syndrome and exotic scoliosis. J Bone Jt Surg Am. 2007;89a:108–22.
22. Haynes DR, Crotti TN, Potter AE, Loric M, Atkins GJ, Howie DW, et al. The osteoclastogenic molecules RANKL and RANK are associated with periprosthetic osteolysis. J Bone Jt Surg Br. 2001;83b:902–11.10.1302/0301-620X.83B6.0830902 ↗
23. Man K, Jiang LH, Foster R, Yang XBB. Immunological responses to total hip arthroplasty. J Funct Biomater. 2017;8:33.10.3390/jfb8030033 ↗
24. Tang JC, Luo JP, Huang YJ, Sun JF, Zhu ZY, Xu JY, et al. Immunological response triggered by metallic 3D printing powders. Addit Manuf. 2020;35:101392.
25. Pabst W, Gregerova E. Characterisation of particle and particle systems. ICT Prague. 2007;1–23.
26. Khan J, Noboru N, Young A, Thomas D. Pro and anti-inflammatory cytokine levels (TNF-α, IL-1β, IL-6 and IL-10) in rat model of neuroma. Pathophysiology. 2017;24:155–9.10.1016/j.pathophys.2017.04.001 ↗
27. Zhou XD, Xi K, Bian J, Li ZA, Wu L, Tang JC, et al. Injectable engineered micro/nano-complexes trigger the reprogramming of bone immune epigenetics. Chem Eng J. 2023;462:142158.10.1016/j.cej.2023.142158 ↗
28. Li J, Li Y, Peng X, Li B, Qin H, Chen Y. In vivo analysis of the effects of CoCrMo and Ti particles on inflammatory responses and osteolysis. RSC Adv. 2018;8:5151–5157.10.1039/C7RA12325F ↗
29. Li Y, Li J, Li B, Qin H, Peng X, Zhao Y, et al. Anthocyanin suppresses CoCrMo particle-induced osteolysis by inhibiting IKKα/β mediated NF-κB signaling in a mouse calvarial model. Mol Immunol. 2017;85:27–34.10.1016/j.molimm.2017.02.003 ↗
30. Wang XM, Liu H, Li JY, Wei JX, Li X, Zhang YL, et al. Rosamultin attenuates acute hypobaric hypoxia-induced bone injuries by regulation of sclerostin and its downstream signals. High Alt Med Biol. 2020;21:273–86.10.1089/ham.2019.0113 ↗
31. Zhou CH, Shi ZL, Meng JH, Hu B, Zhao CC, Yang YT, et al. Sophocarpine attenuates wear particle-induced implant loosening by inhibiting osteoclastogenesis and bone resorption via suppression of the NF-κB signalling pathway in a rat model. Br J Pharm. 2018;175:859–76.10.1111/bph.14092 ↗
32. Anderson IE, Byrd D, Meyer J. Highly tuned gas atomization for controlled preparation of coarse powder. Materialwiss Werkst. 2010;41:504–12.10.1002/mawe.201000636 ↗
33. Gunther A, Lampa A, Fritsching U, Schroder J, Kleinhans A, Gaukel V, et al. Benchmarking of gas-assisted atomization systems for liquid disintegration. Chem Eng Technol. 2016;39:699–707.10.1002/ceat.201500331 ↗
34. Li X, Ominsky MS, Warmington KS, Morony S, Gong J, Cao J, et al. Sclerostin antibody treatment increases bone formation, bone mass, and bone strength in a rat model of postmenopausal osteoporosis. J Bone Min Res. 2009;24:578–88.10.1359/jbmr.081206 ↗
35. Zawawi MSF, Perilli E, Stansborough RL, Marino V, Cantley MD, Xu J, et al. Caffeic acid phenethyl ester abrogates bone resorption in a murine calvarial model of polyethylene particle-induced osteolysis. Calcif Tissue Int. 2015;96:565–74.10.1007/s00223-015-9982-8 ↗
36. Franz S, Rammelt S, Scharnweber D, Simon JC. Immune responses to implants – a review of the implications for the design of immunomodulatory biomaterials. Biomaterials .2011;32:6692–709.10.1016/j.biomaterials.2011.05.078 ↗
37. Green TR, Fisher J, Matthews JB, Stone MH, Ingham E. Effect of size and dose on bone resorption activity of macrophages by in vitro clinically relevant ultra high molecular weight polyethylene particles. J Biomed Mater Res. 2000;53:490–7.10.1002/1097-4636(200009)53:5<490::AID-JBM7>3.0.CO;2-7 ↗
38. Hedberg Y, Gustafsson J, Karlsson HL, Moller L, Wallinder IO. Bioaccessibility, bioavailability and toxicity of commercially relevant iron- and chromium-based particles: in vitro studies with an inhalation perspective. Part Fibre Toxicol. 2010;7:1–14.10.1186/1743-8977-7-23 ↗
39. Otero-González L, García-Saucedo C, Field JA, Sierra-Álvarez R. Toxicity of TiO2, ZrO2, Fe0, Fe2O3, and Mn2O3 nanoparticles to the yeast, Saccharomyces cerevisiae. Chemosphere. 2013;93:1201–6.10.1016/j.chemosphere.2013.06.075 ↗
40. Puerari RC, da Costa CH, Vicentini DS, Fuzinatto CF, Melegari SP, Schmidt ÉC, et al. Synthesis, characterization and toxicological evaluation of Cr2O3 nanoparticles using Daphnia magna and Aliivibrio fischeri. Ecotox Environ Safe. 2016;128:36–43.10.1016/j.ecoenv.2016.02.011 ↗
41. Mosser DM, Edwards JP. Exploring the full spectrum of macrophage activation. Nat Rev Immunol. 2008;8:958–69.10.1038/nri2448 ↗
42. Lebre F, Hearnden CH, Lavelle EC. Modulation of immune responses by particulate materials. Adv Mater. 2016;28:5525–41.10.1002/adma.201505395 ↗
43. Panegrossi G, Ceretti M, Papalia M, Casella F, Favetti F, Falez F. Bone loss management in total knee revision surgery. Int Orthop. 2014;38:419–27.10.1007/s00264-013-2262-1 ↗
44. Assmann G, Kasch R, Maher CG, Hofer A, Barz T, Merk H, et al. Comparison of health care costs between aseptic and two stage septic hip revision. J Arthroplast. 2014;29:1925–31.10.1016/j.arth.2014.04.043 ↗
45. Giertz SH, Fernandes BL, Fernandes CR, Franco CRC. Metallic ions in organs of rats injected with metallic particles of stainless steel 316L and Ti6Al4V alloy. Mater Res-Ibero-Am J 2010;13:35–39.10.1590/S1516-14392010000100009 ↗
46. Miranda RN, Khoury JD, Medeiros LJ. Lymphadenopathy Associated with Joint Prostheses. In: Miranda RN, Khoury JD, Medeiros LJ, (eds.) Atlas of Lymph Node Pathology. New York: Academic; 2013. 149–51.10.1007/978-1-4614-7959-8_35 ↗
47. Liu S, Virdi AS, Sena K, Hughes WF, Sumner DR. Bone turnover markers correlate with implant fixation in a rat model using LPS-doped particles to induced implant loosening. J Biomed Mater Res A 2012;100A:918–28.10.1002/jbm.a.34029 ↗
48. Guo XB, Bai JX, Ge GR, Wang ZD, Wang Q, Zheng K, et al. Bioinspired peptide adhesion on Ti implants alleviates wear particle-induced inflammation and improves interfacial osteogenesis. J Colloid Interf. Science .2022;605:410–24.
49. Bauer TW, Schils J. The pathology of total joint arthroplasty. Skelet Radio. 1999;28:483–97.10.1007/s002560050552 ↗
50. Bauer TW, Schils J. The pathology of total joint arthroplasty. Skelet Radio. 1999;28:423–32.10.1007/s002560050541 ↗
51. Smith RA, Maghsoodpour A, Hallab NJ. In vivo response to cross-linked polyethylene and polycarbonate-urethane particles. J Biomed Mater Res A. 2010;93A:227–34.10.1002/jbm.a.32531 ↗
52. Zawawi MSF, Marino V, Perilli E, Cantley MD, Xu J, Purdue PE, et al. Parthenolide reduces empty lacunae and osteoclastic bone surface resorption induced by polyethylene particles in a murine calvarial model of peri-implant osteolysis. J Biomed Mater Res A. 2015;103:3572–9.10.1002/jbm.a.35484 ↗
53. Park-Min KH. Mechanisms involved in normal and pathological osteoclastogenesis. Cell Mol Life Sci. 2018;75:2519–28.10.1007/s00018-018-2817-9 ↗
54. Ladewig A, Schlick G, Fisser M, Schulze V, Glatzel U. Influence of the shielding gas flow on the removal of process by-products in the selective laser melting process. Addit Manuf. 2016;10:1–9.
55. Sutton AT, Kriewall CS, Leu MC, Newkirk JW, Brown B. Characterization of laser spatter and condensate generated during the selective laser melting of 304L stainless steel powder. Addit Manuf. 2020;31:100904.