journal article·2024-08-13Open access

Assessment of cranial reconstruction utilizing various implant materials: finite element study

Yomna H. Shash

Abstract

Abstract The human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure that involves replacing the removed portion with either autologous bone or alloplastic material. While titanium has traditionally been the preferred material for cranial implants due to its excellent properties and biocompatibility, its limitations have prompted the search for alternative materials. This research aimed to explore alternative materials to titanium for cranial implants in order to address the limitations of titanium implants and improve the performance of the cranioplasty process. A 3D model of a defective skull was reconstructed with a cranial implant, and the implant was simulated using various stiff and soft materials (such as alumina, zirconia, hydroxyapatite, zirconia-reinforced PMMA, and PMMA) as alternatives to titanium under 2000N impact forces. Alumina and zirconia implants were found to reduce stresses and strains on the skull and brain compared to titanium implants. However, PMMA implants showed potential for causing skull damage under current loading conditions. Additionally, PMMA and hydroxyapatite implants were prone to fracture. Despite these findings, none of the implants exceeded the limits for tensile and compressive stresses and strains on the brain. Zirconia-reinforced PMMA implants were also shown to reduce stresses and strains on the skull and brain compared to PMMA implants. Alumina and zirconia show promise as alternatives to titanium for the production of cranial implants. The use of alternative implant materials to titanium has the potential to enhance the success of cranial reconstruction by overcoming the limitations associated with titanium implants. Graphical Abstract
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Facial Trauma and Fracture Management · Craniofacial Disorders and Treatments · Head and Neck Surgical Oncology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (51)

Show source-provided references
1. Richardson J. Clinical and neuropsychological aspects of closed head injury. Psychology Press; Hove: East Sussex; 2013. Retrieved from http://books.google.ie/books?id=1ioVAgAAQBAJ&printsec=frontcover&dq=Clinical+and+Neuropsychological+Aspects+of+Closed+Head+Injury&hl=&cd=1&source=gbs_api10.4324/9781315804538 ↗
2. Aarabi B. Decompressive craniectomy. 2018. Retrieved from http://books.google.ie/books?id=GUhrswEACAAJ&dq=Decompressive+Craniectomy&hl=&cd=2&source=gbs_api
3. Mee H, Anwar F, Timofeev I, Owens N, Grieve K, Whiting G, ... et al. Cranioplasty: a multidisciplinary approach. Front Surg. 2022;9. https://doi.org/10.3389/fsurg.2022.86438510.3389/fsurg.2022.864385 ↗
4. Aydin S, Kucukyuruk B, Abuzayed B, Aydin S, Sanus GZ. Cranioplasty: review of materials and techniques. J Neurosci Rural Pract. 2011;2:162–7. https://doi.org/10.4103/0976-3147.8358410.4103/0976-3147.83584 ↗
5. Antoniac IV. Handbook of bioceramics and biocomposites. Springer International Publishing; 2016. Retrieved from http://books.google.ie/books?id=MWOcAQAACAAJ&dq=Current+Implants+Used+in+Cranioplasty&hl=&cd=1&source=gbs_api
6. Kim CNT, Binh CX, Dung VT, Toan TV. Design and mechanical evaluation of a large cranial implant and fixation parts. Interdiscip Neurosurg. 2023;31:101676 https://doi.org/10.1016/j.inat.2022.10167610.1016/j.inat.2022.101676 ↗
7. Cheng BC. Handbook of spine technology. Springer Cham; Switzerland AG 2021. Retrieved from http://books.google.ie/books?id=itauDQEACAAJ&dq=Mechanical+Implant+Material+Selection,+Durability,+Strength,+and+Stiffness&hl=&cd=1&source=gbs_api
8. Mori Y, Kamimura M, Ito K, Koguchi M, Tanaka H, Kurishima H, et al. A review of the impacts of implant stiffness on fracture healing. Appl Sci. 2024;14:2259 https://doi.org/10.3390/app1406225910.3390/app14062259 ↗
9. Persson J, Helgason B, Engqvist H, Ferguson SJ, Persson C. Stiffness and strength of cranioplastic implant systems in comparison to cranial bone. J Cranio-Maxillofac Surg. 2018;46:418–23. https://doi.org/10.1016/j.jcms.2017.11.02510.1016/j.jcms.2017.11.025 ↗
10. Demirci F, Tekin S, Değer Y. Evaluation of the use of PEEK material in implant-supported fixed restorations by finite element analysis. Niger J Clin Pract. 2019;22:1252 https://doi.org/10.4103/njcp.njcp_144_1910.4103/njcp.njcp_144_19 ↗
11. Moharil S, Reche A, & Durge K Polyetheretherketone (PEEK) as a biomaterial: an overview. Cureus. 2023. https://doi.org/10.7759/cureus.4430710.7759/cureus.44307 ↗
12. Zhu S, Chen Y, Lin F, Chen Z, Jiang X, Zhang J, et al. Complications following titanium cranioplasty compared with nontitanium implants cranioplasty: A systematic review and meta-analysis. J Clin Neurosci: Off J Neurosurg Soc Australas. 2021;84:66–74. https://doi.org/10.1016/j.jocn.2020.12.00910.1016/j.jocn.2020.12.009 ↗
13. Kim KT, Eo MY, Nguyen TTH, & Kim SM. General review of titanium toxicity. Int J Implant Dent. 2019;5. https://doi.org/10.1186/s40729-019-0162-x10.1186/s40729-019-0162-x ↗
14. Albrektsson T, Chrcanovic B, Mölne J, Wennerberg A. Foreign body reactions, marginal bone loss and allergies in relation to titanium implants. Eur J Oral Implantol. 2018;11:S37–S46.
15. Fretwurst T, Nelson K, Tarnow D, Wang HL, Giannobile W. Is metal particle release associated with peri-implant bone destruction? An emerging concept. J Dent Res. 2017;97:259–65. https://doi.org/10.1177/002203451774056010.1177/0022034517740560 ↗
16. Jain MS, Lingarajah S, Luvsannyam E, Somagutta MR, Jagani RP, Sanni J, et al. Delayed titanium hypersensitivity and retained foreign body causing late abdominal complications. Case Rep Surg. 2021;2021:1–6. https://doi.org/10.1155/2021/551540110.1155/2021/5515401 ↗
17. Thamaraiselvi T, Rajeswari S. Biological evaluation of bioceramic materials—a review. Carbon. 2004;24:172.
18. Siracusa V, Maimone G, Antonelli V. State-of-art of standard and innovative materials used in cranioplasty. Polymers. 2021;13:1452 https://doi.org/10.3390/polym1309145210.3390/polym13091452 ↗
19. Geogi CC, Rawat A, Dubey S, Singh P. Bioceramics in endodontics—a review. IP Indian J Conserv Endod. 2023;7:163–71. https://doi.org/10.18231/j.ijce.2022.03710.18231/j.ijce.2022.037 ↗
20. Hilal MK. Review of literature on bioceramics. Glob J Res Anal. 2012;3:1–3. https://doi.org/10.15373/22778160/apr2014/90. D. M. K. H.10.15373/22778160/apr2014/90 ↗
21. Maenhoudt W, Hallaert G, Kalala JP, Baert E, Dewaele F, Bauters W, et al. Hydroxyapatite cranioplasty: a retrospective evaluation of osteointegration in 17 cases. Acta Neurochir. 2018;160:2117–24. https://doi.org/10.1007/s00701-018-3694-610.1007/s00701-018-3694-6 ↗
22. Pepla E. Nano-hydroxyapatite and its applications in preventive, restorative and regenerative dentistry: a review of literature. Ann Stomatol. 2014. https://doi.org/10.11138/ads/2014.5.3.10810.11138/ads/2014.5.3.108 ↗
23. Zafar MS. Prosthodontic applications of polymethyl methacrylate (PMMA): an update. Polymers. 2020;12:2299 https://doi.org/10.3390/polym1210229910.3390/polym12102299 ↗
24. Ali U, Karim KJBA, Buang NA. A review of the properties and applications of poly (methyl methacrylate) (PMMA). Polym Rev. 2015;55:678–705. https://doi.org/10.1080/15583724.2015.103137710.1080/15583724.2015.1031377 ↗
25. Leão RDS, Moraes SLDD, Gomes JMDL, Lemos CAA, Casado BGDS, Vasconcelos BCDE, et al. Influence of addition of zirconia on PMMA: a systematic review. Mater Sci Eng C. 2020;106:110292 https://doi.org/10.1016/j.msec.2019.11029210.1016/j.msec.2019.110292 ↗
26. Chęcińska K, Chęciński M, Sikora M, Nowak Z, Karwan S, Chlubek D. The effect of zirconium dioxide (ZrO2) nanoparticles addition on the mechanical parameters of polymethyl methacrylate (PMMA): a systematic review and meta-analysis of experimental studies. Polymers. 2022;14:1047 https://doi.org/10.3390/polym1405104710.3390/polym14051047 ↗
27. Lakshmininarayana H. Finite elements analysis: procedures in engineering. Universities Press: India; 2004. Retrieved from http://books.google.ie/books?id=12wLpL9wILMC&printsec=frontcover&dq=Finite+Elements+Analysis:+Procedures+in+Engineering&hl=&cd=2&source=gbs_api
28. Yang ZC. Finite element analysis for biomedical engineering applications. CRC Press: London; Newyork; 2019. Retrieved from http://books.google.ie/books?id=7tSNDwAAQBAJ&printsec=frontcover&dq=Finite+Element+Analysis+for+Biomedical+Engineering+Applications&hl=&cd=1&source=gbs_api10.1201/9780429061264 ↗
29. Santos PO, Carmo GP, Sousa RJAD, Fernandes FAO, Ptak M. Mechanical strength study of a cranial implant using computational tools. Appl Sci. 2022;12:878 https://doi.org/10.3390/app1202087810.3390/app12020878 ↗
30. Wan Z, Huang C, Li Y, Wan C, & Zhong R. The evaluation of bio-mechanical properties of four different skull implants by finite element methods. Biomed Res. 2018;29. https://doi.org/10.4066/biomedicalresearch.29-18-13910.4066/biomedicalresearch.29-18-139 ↗
31. lifesciencedb.jp. (n.d.). Body parts 3D/anatomography: select parts and make embeddable model of your own. Available at: https://lifesciencedb.jp/bp3d/
32. Tsouknidas A, Maropoulos S, Savvakis S, Michailidis N. FEM assisted evaluation of PMMA and Ti6Al4V as materials for cranioplasty resulting mechanical behaviour and the neurocranial protection. Bio-Med Mater Eng. 2011;21:139–47. https://doi.org/10.3233/bme-2011-066310.3233/bme-2011-0663 ↗
33. Geraldes DM, Phillips ATM. A comparative study of orthotropic and isotropic bone adaptation in the femur. Int J Numer Methods Biomed Eng. 2014;30:873–89. https://doi.org/10.1002/cnm.263310.1002/cnm.2633 ↗
34. Beer FP, Johnston ER, DeWolf JT, Mazurek DF, & Sanghi S. Mechanics of materials. 2017. Retrieved from http://books.google.ie/books?id=MndeAQAACAAJ&dq=Mechanics+of+materials:+Seventh+edition&hl=&cd=1&source=gbs_api
35. Martínez-Valencia M, Navarro C, Vázquez-López J, Hernández-Arellano J, Jiménez-García J, & Díaz-León J. Optimization of titanium cranial implant designs using generalized reduced gradient method, analysis of finite elements, and artificial neural networks. Rev Int Métodos Numéricos Para Cálculo Y Diseño En Ingeniería, 2022;38. https://doi.org/10.23967/j.rimni.2022.06.00410.23967/j.rimni.2022.06.004 ↗
36. Beer FP, Johnston ER, DeWolf JT, Mazurek DF, & Sanghi, S. (2017). Mechanics of Materials. McGraw-Hill Education (India). Retrieved from http://books.google.ie/books?id=MndeAQAACAAJ&dq=Mechanics+of+materials:+Seventh+edition&hl=&cd=1&source=gbs_api
37. Christensen RM. The theory of materials failure. Oxford University Press; United Kingdom; 2013. Retrieved from http://books.google.ie/books?id=MwxGWnG7t58C&printsec=frontcover&dq=The+theory+of+materials+failure&hl=&cd=1&source=gbs_api10.1093/acprof:oso/9780199662111.001.0001 ↗
38. Sugiura T, Yamamoto K, Horita S, Murakami K, Tsutsumi S, Kirita T. The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis. J Periodontal Implant Sci. 2016;46:152 https://doi.org/10.5051/jpis.2016.46.3.15210.5051/jpis.2016.46.3.152 ↗
39. Frassanito P, Massimi L, Tamburrini G, Bianchi F, Nataloni A, Canella V, et al. Custom-made hydroxyapatite for cranial repair in a specific pediatric age group (7–13 years old): a multicenter post-marketing surveillance study. Child’s Nerv Syst. 2018;34:2283–9. https://doi.org/10.1007/s00381-018-3905-810.1007/s00381-018-3905-8 ↗
40. Bergmann C & Stumpf A. Dental ceramics. Springer Science & Business Media: Brazil; 2013. Retrieved from http://books.google.ie/books?id=kfg_AAAAQBAJ&printsec=frontcover&dq=Ceramics+in+Dentistry%E2%80%94Part+I:+Classes+of+Materials&hl=&cd=1&source=gbs_api
41. Denry I, Holloway J. Ceramics for dental applications: a review. Materials. 2010;3:351–68. https://doi.org/10.3390/ma301035110.3390/ma3010351 ↗
42. Kobayashi S, Hara H, Okudera H, Takemae T, Sugita K. Usefulness of ceramic implants in neurosurgery. Neurosurgery. 1987;21:751–5. https://doi.org/10.1227/00006123-198711000-0003210.1227/00006123-198711000-00032 ↗
43. Properties: alumina as a biomaterial (99.5% alumina). (n.d.). Retrieved from https://www.azom.com/properties.aspx?ArticleID=105
44. Zafar MS, Ahmed N. Nanoindentation and surface roughness profilometry of poly methyl methacrylate denture base materials. Technol Health Care. 2014;22:573–81. https://doi.org/10.3233/thc-14083210.3233/thc-140832 ↗
45. Jindal P, Chaitanya, Bharadwaja SSS, Rattra S, Pareek D, Gupta V, et al. Optimizing cranial implant and fixture design using different materials in cranioplasty. Proc Inst Mech Eng, Part L: J Mater: Des Appl. 2022;237:107–21. https://doi.org/10.1177/1464420722110487510.1177/14644207221104875 ↗
46. Miller K. Biomechanics of the brain. Springer; Austalia; 2019. Retrieved from http://books.google.ie/books?id=iEuoDwAAQBAJ&printsec=frontcover&dq=brain+tissue+mechanical+properties&hl=&cd=1&source=gbs_api
47. Leipzig ND, Shoichet MS. The effect of substrate stiffness on adult neural stem cell behavior. Biomaterials. 2009;30:6867–78. https://doi.org/10.1016/j.biomaterials.2009.09.00210.1016/j.biomaterials.2009.09.002 ↗
48. Taylor Z, Miller K. Reassessment of brain elasticity for analysis of biomechanisms of hydrocephalus. J Biomech. 2004;37:1263–9. https://doi.org/10.1016/j.jbiomech.2003.11.02710.1016/j.jbiomech.2003.11.027 ↗
49. Technical Products, Zirconia (ZrO2) - YTZP material specifications, https://www.technicalproductsinc.com/pdf/Specs/Zirconia%20YTZP%20Specs.pdf
50. Calcium hydroxyapatite, Ca10(PO4)6(OH)2. (n.d.). Retrieved from https://www.matweb.com/search/datasheet_print.aspx?matguid=e1654c43ab994d7fab5e0f9aabe4dddc
51. Gunjal B and Mandale MB. Numerical study of stresses in dental materials by using finite element analysis. JournalNX, 2018;347–52