Evaluation of nickel release from Ni-Ti stents in various media for safety assessment purposes
Source abstract
Abstract
Nickel (Ni) was an essential component of Ni-Ti alloys used in cardiovascular implants. However, the release of Ni from these alloys might pose potential health risks. This study aimed to identify a simple extraction medium for evaluating Ni release from Ni-Ti alloys and to establish safety assessment guidelines. Seven extraction media, including 0.005% HCl and goat whole blood, were tested. The Ni release was analyzed using inductively coupled plasma atomic emission spectroscopy (ICP-AES) and statistical methods. The results indicated that 0.005% HCl could replace goat blood, as it showed comparable Ni release levels and provided a more conservative assessment. The optimal extraction medium was validated over 41 days at 37 °C. The Ni release curves demonstrated higher release in 0.005% HCl than in physiological media. Safety evaluation against the International Council for Harmonisation's (ICH) permissible daily exposure (PDE) of 20 μg/day revealed that some samples exceeded the limits, highlighting the need for stringent risk assessment. This study provided a practical method for Ni release evaluation, supporting regulatory oversight and enhancing product safety in the medical device industry.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Hydrogen embrittlement and corrosion behaviors in metals · Orthopaedic implants and arthroplasty · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. Biesiekiersk A, Wang J, Gepreel MA-H, Wen C. A new look at biomedical Ti-based shape memory alloys. Acta Biomater. 2012;8:1661–9.10.1016/j.actbio.2012.01.018 ↗
2. American Cancer Society cancer.org 1.800.227.2345
3. Riedel F, Aparicio-Soto M, Curato C, Thierse H-J, Siewert K, Luch A. Immunological mechanisms of metal allergies and the nickel-specific TCR-pMHC interface. Int J Environ Res Public Health. 2021;18:10867.10.3390/ijerph182010867 ↗
4. Ramagopal G, Duggal B, Bansal NO, Narayana G. Study of nickel levels in patients with atrial septal defect undergoing Amplatzer device closure. Heart Views. 2018;19:85–87.10.4103/HEARTVIEWS.HEARTVIEWS_76_17 ↗
5. Elkiran O, Karakurt C, Koca G, Taskapan C. Serum nickel and titanium levels after transcatheter closure of atrial septal defects with Amplatzer septal occluder. Cardiol Res Pr. 2019;2019:7891746.
6. Zhang Z, Fu B, Zhang D, Zhang Z, Cheng Y, Sheng L, et al. Safety and efficacy of nano lamellar TiN coatings on nitinol atrial septal defect occluders in vivo. Mater Sci Eng C Mater Biol Appl. 2013;33:1355–60.10.1016/j.msec.2012.12.036 ↗
7. Wichai W, Anuwongnukroh N, Dechkunakorn S. Comparison of chemical properties and Ni release of stainless steel and nickel titanium wires. Adv Mater Res. 2014;884–885:560–5.10.4028/www.scientific.net/AMR.884-885.560 ↗
8. Fernandes P, Sharma S-R, Magee A, Michielon G, Fraisse A. Severe migraine associated with nickel allergy requiring surgical removal of atrial septal device. Ann Thorac Surg. 2019;108:e183–e184.10.1016/j.athoracsur.2019.01.034 ↗
9. Močnik P, Kosec A, Kovač J, Bizjak M. The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires. Mater Sci Eng C Mater Biol Appl. 2017;78:682–9.10.1016/j.msec.2017.04.050 ↗
10. Apostolos A, Drakopoulou M, Toutouza K. New migraines after atrial septal defect occlusion. Is the nickel hypersensitivity the start of everything? Med Hypotheses. 2021;146:110442.10.1016/j.mehy.2020.110442 ↗
11. Center for Devices and Radiological Health, Non-Clinical Engineering Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems, Dec 18 2018.
12. GB24627-2009 Standard specification for wrought Nickel-Titanium shape memory alloys for medical devices and surgical implants.
13. ASTM F2063-18 Standard Specification for Wrought Nickel-Titanium Shape Memory Alloys for Medical Devices and Surgical Implants.
14. ISO 16429:2004 Implants for surgery—Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods.
15. YY/T 1552-2017 Implants for surgery—Measurements of open-circuit potential to assess corrosion behaviour of metallic implantable materials and medical devices over extended time periods.
16. ASTM F2129-06 Standard Test Method For Conducting Cyclic Potentiodynamic Polarization Measurements To Determine The Corrosion Susceptibility Of Small Implant Devices.
17. Siddiqui DA, Sivan S, Weaver JD, Prima MD. Effect of wire fretting on the corrosion resistance of common medical alloys. J Biomed Mater Res B Appl Biomater. 2017;105:2487–94.10.1002/jbm.b.33788 ↗
18. ASTM F3306-19 Standard Test Method for Ion Release Evaluation of Medical Implants.
19. ISO 10993-12:2021 Biological evaluation of medical devices—Part 12: Sample preparation and reference materials.
20. YY/T 1823-2022 Cardiovascular implants-Standard test method for nickel ion release of nickel-titanium alloy.
21. YY/T 1802-2021 Additive manufacturing medical product-3D printing titanium alloy implant metal ion precipitation evaluation method.
22. Commission Regulation (EC). No. 552/2009 of 22 June 2009 amending Regulation (EC), No. 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) as regards Annex XVII, Annex: Entry 27. J Eur Union 2009;L164:7–9.
23. N.m.P. Administration, Standard specification for wrought Nickel-Titanium shape memory alloys for medical devices and surgical implants, GB24627-2009, Standards Press of China 2009.
24. Jia L-H, Li Y, Li Y-Z. Determination of wholesome elements and heavy metals in safflower (Carthamus tinctorius L.) from Xinjiang and Henan by ICP-MS/ICP-AES. J Pharm Anal. 2011;1:100–3.10.1016/S2095-1779(11)70017-X ↗
25. Ribeiro AM, Estevinho BN, Rocha F. Microencapsulation of polyphenols—the specific case of the microencapsulation of Sambucus Nigra L. extracts—a review. Trends Food Sci Technol. 2020;105:454–67.10.1016/j.tifs.2019.03.011 ↗
26. International Coordination of Technical Requirements for the Registration of Medicines for Human Use, “Guidelines for elemental impurities,” 2022.
27. Suarez C, Vilar T, Gil J, Sevilla P. In vitro evaluation of surface topographic changes and nickel release of lingual orthodontic archwires. J Mater Sci: Mater Med. 2010;21:675–83. https://doi.org/10.1007/s10856-009-3898-710.1007/s10856-009-3898-7 ↗
28. General Administration of Quality Supervision, Jewellery-Determination of the release of Nickel-Method of spectrometry, GB/T19719-2005, Standards Press of China, 2005.
29. General Administration of Quality Supervision, Determination of nickel released from accessories on textile products, GB/T30158-2013, Standards Press of China, 2013.
30. Talha M, Ma Y, A YL, Mandal AK, Sinha OP, Kong X. Corrosion performance of various deformed surfaces of implant steel for coronary stent applications: effect of protein concentration. Colloids Surf B Biointerfaces. 2021;197:111407.10.1016/j.colsurfb.2020.111407 ↗
31. Feng Z, Li J, Yang Z, Buchheit R. The effect of vanadate, phosphate, fluoride compounds on the aqueous corrosion of magnesium alloy AZ31 in dilute chloride solutions. Materials. 2020;13:1325.10.3390/ma13061325 ↗
32. Aparicio M, Mosa J, Rodriguez G, Guzman J, Picard Q, Klein LC, et al. Consolidated melting gel coatings on AZ31 magnesium alloy with excellent corrosion resistance in NaCl solutions: an interface study. Appl Mater Interfaces. 2019;11:3493–505.10.1021/acsami.8b20199 ↗
33. Yang Z, Kan B, Li J, Su Y, Qiao L, Volinsky AA. A statistical study on the effect of hydrostatic pressure on metastable pitting corrosion of X70 pipeline steel. Materials. 2017;10:1307.10.3390/ma10111307 ↗
34. Scherer J, Ocko BM, Magnussen OM. Structure, dissolution, and passivation of Ni(111) electrodes in sulfuric acid solution: an in situ STM, X-ray scattering, and electrochemical study. Electrochim Acta. 2003;48:1169–91.10.1016/S0013-4686(02)00827-7 ↗
35. The United States Pharmacopeial Convention, U.S. Pharmacopeia/National Formulary, 2013.