A comprehensive review on the State of the Art in the research and development of poly-ether-ether-ketone (PEEK) biomaterial-based implants
Source abstract
Abstract
Polyetheretherketone (PEEK) is a preferred high-performance polymer in the spine, orthopedic, and craniomaxillofacial implant industry. However, despite its commendable mechanical properties, its bioinert nature limits the implants from integrating with neighboring tissues, impacting the implant's long-term performance. To address this limitation, various kinds of surface functionalization techniques have been developed over the years. Noteworthy efforts have been made to incorporate bioactive fillers in the PEEK matrix to develop standalone bioactive composites. In personalized medicine, significant advances have been made in the 3D Printing of PEEK implants. 3D-printed PEEK implants are now being developed at Point-of-Care, significantly reducing manufacturing and logistic time. Given the recent clinical follow-up updates and advancements in PEEK-based implants, PEEK implants are witnessing an important phase in its history. Recognizing this vital phase, this paper aims to comprehensively review the advancements of PEEK implants over the past decade. The review starts with an overview of the clinical impact of varying PEEK implants, followed by PEEK's surface functionalization techniques and engineering of PEEK-based bioactive composites. Next, this review describes the advancements made in the 3D printing of PEEK implants and points out the essential considerations that should be considered when developing 3D-printed PEEK-based implants. Finally, the review ends with an estimated projection about the future of PEEK-based implants. Readers are expected to gain an all-encompassing and in-depth understanding of PEEK biomedical implants' past, present, and future, enabling researchers to advance the research and development of PEEK-based implants in the required direction. STATEMENT OF SIGNIFICANCE: PEEK is a preferred high-performance polymer in the implant industry, with notable benefits over metallic and ceramic implants, such as bone-matching stiffness and durability. Significant strides have been made in the last decade to make PEEK implants bioactive and utilize 3D Printing to develop patient-specific implants. Given the recent advancements in PEEK-based implants, this review aims to provide an all-encompassing and in-depth understanding of PEEK biomedical implants' past, present, and future. It will comprehensively discuss the know-how gained from the clinical follow-up, the strategies to address the limitations of PEEK implants, and the essential considerations in 3D Printing of PEEK implants. This review will enable researchers to advance the research and development of PEEK implants in the required direction.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Additive Manufacturing and 3D Printing Technologies · 3D Printing in Biomedical Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Polyetheretherketones
2. Polyetheretherketone
3. PEEK biomaterials in trauma, orthopedic, and spinal implants10.1016/j.biomaterials.2007.07.013 ↗
4. Poly-Ether-Ether-Ketone (PEEK) in orthopaedic practice–a current concept review10.1016/j.jorep.2022.03.013 ↗
5. Polyetheretherketone (PEEK) for medical applications10.1007/s10856-016-5731-4 ↗
6. PEEK versus titanium cages in lateral lumbar interbody fusion: a comparative analysis of subsidence10.3171/2020.6.FOCUS20367 ↗
7. Comparison between 3-dimensional-printed titanium and polyetheretherketone cages: 1-year outcome after minimally invasive transforaminal interbody fusion10.14245/ns.2244140.070 ↗
8. A comparison of polyetheretherketone and titanium-coated polyetheretherketone in minimally invasive transforaminal lumbar interbody fusion: a randomized clinical trial10.1016/j.wneu.2022.10.006 ↗
9. Titanium-coated PEEK versus uncoated PEEK cages in lumbar interbody fusion: a systematic review and meta-analysis of randomized controlled trial10.1097/BSD.0000000000001378 ↗
10. Comparison in the same intervertebral space between titanium-coated and uncoated PEEK cages in lumbar interbody fusion surgery10.1016/j.jos.2019.07.004 ↗
11. Integral fixation titanium/polyetheretherketone cages for cervical arthrodesis: evolution of cage design and early radiological outcomes and fusion rates10.1111/os.12413 ↗
12. Titanium vs. polyetheretherketone (PEEK) interbody fusion: meta-analysis and review of the literature10.1016/j.jocn.2017.06.062 ↗
13. Titanium (Ti) cages may be superior to polyetheretherketone (PEEK) cages in lumbar interbody fusion: a systematic review and meta-analysis of clinical and radiological outcomes of spinal interbody fusions using Ti versus PEEK cages10.1007/s00586-021-06748-w ↗
14. Polyetheretherketone versus titanium cages for posterior lumbar interbody fusion: meta-analysis and review of the literature10.14245/ns.2040058.029 ↗
15. Comparison of fusion rates following transforaminal lumbar interbody fusion using polyetheretherketone cages or titanium cages with transpedicular instrumentation10.1007/s00586-014-3466-9 ↗
16. Titanium interlayer-mediated hydroxyapatite-coated polyetheretherketone cage in transforaminal lumbar interbody fusion surgery10.1186/s12891-021-04803-7 ↗
17. Transforaminal lumbar interbody fusion using polyetheretherketone oblique cages with and without a titanium coating: a randomised clinical pilot study10.1302/0301-620X.99B10.BJJ-2016-1292.R2 ↗
18. Randomized controlled trial of posterior lumbar interbody fusion with Ti-and CaP-nanocoated polyetheretherketone cages: comparative study of the 1-year radiological and clinical outcome10.14444/6080 ↗
19. Two-year results of a double-blind multicenter randomized controlled non-inferiority trial of polyetheretherketone (PEEK) versus silicon nitride spinal fusion cages in patients with symptomatic degenerative lumbar disc disorders10.21037/jss-20-588 ↗
20. T. Hasegawa, H. Ushirozako, E. Shigeto, T. Ohba, H. Oba, K. Mukaiyama, S. Shimizu, Y. Yamato, K. Ide, Y. Shibata, The titanium-coated PEEK cage maintains better bone fusion with the endplate than the PEEK cage 6 months after PLIF surgery: a multicenter, prospective, randomized study, LWW, 2020.10.1097/BRS.0000000000003464 ↗
21. PLIF surgery with titanium-coated PEEK or uncoated PEEK cages: a prospective randomised clinical and radiological study10.1007/s00586-020-06642-x ↗
22. Outcome of Ti/PEEK versus PEEK cages in minimally invasive transforaminal lumbar interbody fusion10.1177/21925682211000323 ↗
23. Comparison between acrylic cage and polyetheretherketone (PEEK) cage in single-level anterior cervical discectomy and fusion: a randomized clinical trial10.1097/BSD.0000000000000251 ↗
24. Evaluation of cage subsidence in standalone lateral lumbar interbody fusion: novel 3D-printed titanium versus polyetheretherketone (PEEK) cage10.1007/s00586-021-06912-2 ↗
25. Comparison of lumbar interbody fusion with 3D-printed porous titanium cage versus polyetheretherketone cage in treating lumbar degenerative disease: a systematic review and meta-analysis
26. Fusion assessment in standalone lateral lumbar interbody fusion: 3D-printed titanium versus polyetheretherketone (PEEK) cages10.21037/jss-22-17 ↗
27. Bony ingrowth potential of 3D-printed porous titanium alloy: a direct comparison of interbody cage materials in an in vivo ovine lumbar fusion model10.1016/j.spinee.2018.02.018 ↗
28. Early outcomes of three-dimensional–printed porous titanium versus polyetheretherketone cage implantation for stand-alone lateral lumbar interbody fusion in the treatment of symptomatic adjacent segment degeneration10.1016/j.wneu.2021.11.122 ↗
29. Three-dimensional-printed titanium versus polyetheretherketone cages for lumbar interbody fusion: a systematic review of comparative in vitro, animal, and human studies10.14245/ns.2346244.122 ↗
30. The therapeutic effect of patient-specific implants in cranioplasty10.1016/j.jcms.2016.10.016 ↗
31. Cranioplasty complications and risk factors associated with bone flap resorption10.1186/s13049-015-0155-6 ↗
32. A randomised controlled trial comparing autologous cranioplasty with custom-made titanium cranioplasty: long-term follow-up10.1007/s00701-018-3514-z ↗
33. Autologous cranioplasty is associated with increased reoperation rate: a systematic review and meta-analysis10.1016/j.wneu.2018.05.009 ↗
34. Materials used in cranioplasty: a history and analysis10.3171/2014.2.FOCUS13561 ↗
35. Complications of titanium cranioplasty–a retrospective analysis of 174 patients10.1007/s00701-014-2024-x ↗
36. Complications following titanium cranioplasty compared with nontitanium implants cranioplasty: a systematic review and meta-analysis10.1016/j.jocn.2020.12.009 ↗
37. Exposure of titanium implants after cranioplasty: a matter of long-term consequences10.1016/j.inat.2017.01.015 ↗
38. A retrospective comparative analysis of titanium mesh and custom implants for cranioplasty10.1093/neuros/nyz358 ↗
39. Mortality after local allergic response to titanium cranioplasty10.1007/s00701-012-1429-7 ↗
40. Computer-designed polyetheretherketone implants versus titanium mesh (±acrylic cement) in alloplastic cranioplasty: a retrospective single-surgeon, single-center study10.1097/SCS.0000000000000623 ↗
41. Comparison of polyetheretherketone and titanium cranioplasty after decompressive craniectomy10.1016/j.wneu.2014.06.003 ↗
42. Surgical and patient-reported outcomes in patients with PEEK versus titanium cranioplasty reconstruction10.1097/SCS.0000000000007192 ↗
43. Outcomes following polyetheretherketone (PEEK) cranioplasty: systematic review and meta-analysis10.1016/j.jocn.2017.03.028 ↗
44. Preliminary results of a prospective study on methods of cranial reconstruction10.1016/j.joms.2015.07.008 ↗
45. Outcome and risk factors of complications after cranioplasty with polyetheretherketone and titanium mesh: a single-center retrospective study10.3389/fneur.2022.926436 ↗
46. Adult cranioplasty reconstruction with customized cranial implants: preferred technique, timing, and biomaterials10.1097/SCS.0000000000004385 ↗
47. Craniofacial reconstruction using patient-specific implants polyether ether ketone with computer-assisted planning10.1097/SCS.0000000000001443 ↗
48. Outcome in patient-specific PEEK cranioplasty: a two-center cohort study of 40 implants10.1016/j.jcms.2016.07.005 ↗
49. The application of polyetheretherketone (PEEK) implants in cranioplasty10.1016/j.brainresbull.2019.08.010 ↗
50. Quantitative assessment of point-of-care 3D-printed patient-specific polyetheretherketone (PEEK) cranial implants10.3390/ijms22168521 ↗
51. Polyetheretherketone implants for the repair of large cranial defects: a 3-center experience10.1227/NEU.0000000000000477 ↗
52. Reconstruction of cranial vault defect with polyetheretherketone implants10.1016/j.wneu.2017.04.049 ↗
53. Patient-specific polyetheretherketone implants for repair of craniofacial defects10.1097/SCS.0000000000001413 ↗
54. Polyetheretherketone custom-made implants for craniofacial defects: report of 14 cases and review of the literature10.1016/j.jcms.2015.04.028 ↗
55. Computed-tomography modeled polyether ether ketone (PEEK) implants in revision cranioplasty10.1016/j.bjps.2014.11.001 ↗
56. Cranial reconstruction with polyetheretherketone patient-specific implant: a single-center experience10.1007/s00238-023-02083-z ↗
57. Customized polyetheretherketone (PEEK) implants are associated with similar hospital length of stay compared to autologous bone used in cranioplasty procedures10.1016/j.jns.2022.120169 ↗
58. Integrated porous polyetheretherketone implants for treating skull defect10.1016/j.jmrt.2022.11.122 ↗
59. Primary and secondary reconstruction of complex craniofacial defects using polyetheretherketone custom-made implants10.1016/j.jcms.2015.06.043 ↗
60. Applications of polyetheretherketone in craniomaxillofacial surgical reconstruction
61. Use of customized polyetheretherketone (PEEK) implants in the reconstruction of complex maxillofacial defects10.1001/archfaci.11.1.53 ↗
62. The utility of polyether-ether-ketone implants adjacent to sinus cavities after craniofacial trauma10.1016/j.joms.2018.05.002 ↗
63. The use of patient specific polyetheretherketone implants for reconstruction of maxillofacial deformities10.1016/j.jcms.2019.03.018 ↗
64. Polyetheretherketone patient-specific implants (PPSI) for the reconstruction of two different mandibular contour deformities10.1007/s10006-021-00984-6 ↗
65. PEEK implants: an innovative solution for facial aesthetic surgery
66. Risk factors for postoperative inflammatory complications after maxillofacial reconstruction using polyether-ether-ketone implants10.1016/j.joms.2020.09.039 ↗
67. Clinical application of 3D-printed PEEK implants for repairing mandibular defects10.1016/j.jcms.2022.06.002 ↗
68. The use of interlocking polyetheretherketone (PEEK) patient-specific facial implants in the treatment of facial deformities. A retrospective review of ten patients10.1016/j.joms.2020.12.009 ↗
69. Mandibular recontouring with polyetheretherketone (PEEK) patient-specific implants10.1136/bcr-2022-248826 ↗
70. Accurate reconstruction of bone defects in orbital–maxillary–zygomatic (OMZ) complex with polyetheretherketone (PEEK)10.1016/j.bjps.2021.11.101 ↗
71. Use of virtual surgical planning for simultaneous maxillofacial osteotomies and custom polyetheretherketone implant in secondary orbito-frontal reconstruction: importance of restoring orbital volume10.1097/SCS.0000000000003313 ↗
72. Fatigue and fracture resistance testing of polyether ether ketone (PEEK) implant abutments in an ex vivo chewing simulator model10.3390/ma15196927 ↗
73. Fatigue limits of different PEEK materials for dental implants10.1016/j.jmbbm.2016.12.019 ↗
74. The role of polyether ether ketone (PEEK) in dentistry–a review10.25122/jml-2019-0003 ↗
75. PEEK dental implants: a review of the literature10.1563/AAID-JOI-D-11-00002 ↗
76. PEEK materials as an alternative to titanium in dental implants: a systematic review10.1111/cid.12706 ↗
77. Oral microbial colonization on titanium and polyetheretherketone dental implant healing abutments: an in vitro and in vivo study10.1016/j.prosdent.2023.08.010 ↗
78. Bioactivity and osseointegration of PEEK are inferior to those of titanium: a systematic review10.1563/aaid-joi-D-16-00072 ↗
79. PEEK in fixed dental prostheses: application and adhesion improvement10.3390/polym14122323 ↗
80. Applications of polyetheretherketone (PEEK) in oral implantology and prosthodontics10.1016/j.jpor.2015.10.001 ↗
81. Behavior of polyether-ether-ketone (PEEK) in prostheses on dental implants. A review10.4317/jced.58102 ↗
82. Biomechanical analyses of one-piece dental implants composed of titanium, zirconia, PEEK, CFR-PEEK, or GFR-PEEK: stresses, strains, and bone remodeling prediction by the finite element method10.1002/jbm.b.34890 ↗
83. Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants10.1016/j.jmbbm.2017.09.005 ↗
84. Randomized clinical trial of zirconia and polyetheretherketone implant abutments for single-tooth implant restorations: a 5-year evaluation10.1016/j.prosdent.2021.02.037 ↗
85. Clinical applications of polyetheretherketone in removable dental prostheses: accuracy, characteristics, and performance10.3390/polym14214615 ↗
86. Polyetherketoneketone (PEKK): an emerging biomaterial for oral implants and dental prostheses10.1016/j.jare.2020.09.004 ↗
87. Polyether ether ketones (PEEK): properties and applications as implants for alternative dentistry materials: a narrative review10.4103/jioh.jioh_10_22 ↗
88. The biologic response to polyetheretherketone (PEEK) wear particles in total joint replacement: a systematic review10.1007/s11999-016-4976-z ↗
89. PEEK versus titanium locking plates for proximal humerus fracture fixation: a comparative biomechanical study in two-and three-part fractures10.1007/s00402-016-2620-8 ↗
90. Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today
91. Carbon fibre reinforced PEEK versus traditional metallic implants for orthopaedic trauma surgery: a systematic review10.1016/j.jcot.2021.101674 ↗
92. Carbon fiber reinforced PEEK optima–a composite material biomechanical properties and wear/debris characteristics of CF-PEEK composites for orthopedic trauma implants10.1016/j.jmbbm.2012.09.013 ↗
93. Biomechanical comparison between stainless steel, titanium and carbon-fiber reinforced polyetheretherketone volar locking plates for distal radius fractures10.1016/j.otsr.2018.05.002 ↗
94. The treatment of proximal humerus fracture using internal fixation with fixed-angle plates: a randomized controlled study comparing carbon fiber reinforced polyetheretherketone with titanium
95. Early comparative outcomes of carbon fiber–reinforced polymer plate in the fixation of distal femur fractures10.1097/BOT.0000000000001223 ↗
96. Clinical outcomes of proximal femoral fractures treated with a novel carbon fiber-reinforced polyetheretherketone intramedullary nail10.1016/j.injury.2020.01.007 ↗
97. Clinical outcome of carbon fiber reinforced polyetheretherketone plates in patients with proximal humeral fracture: one-year follow-up10.3390/jcm12216881 ↗
98. Plasma treatment of polyether-ether-ketone: a means of obtaining desirable biomedical characteristics10.1016/j.eurpolymj.2019.06.030 ↗
99. Surface phosphonation enhances hydroxyapatite coating adhesion on polyetheretherketone and its osseointegration potential10.1016/j.actbio.2016.10.004 ↗