Implants coated with bioactive glass by CO2-laser, an in vivo study

N. Moritz, S Rossi, E. Vedel, T. Tirri, H. Ylänen, H. Aro, T Närhi

Publisher page

Abstract

Due to ageing of the population, the number of revision operations is expected to increase. Thus good fixation of medical implants is crucial for successful treatment. In our previous studies, a method to coat titanium implants with bioactive glass (BAG) via CO2 laser treatment was introduced. It allows to localise the application of a bioactive coating, without heat treatment of the whole implant. In the present study, cylindrical titanium implants were used (BAG-coated, control group: NaOH-treated and grit-blasted Ti). Three implants were placed in each femoral epicondyle of six rabbits. After eight weeks the animals were sacrificed. Half of the implants were subjected to a torsional loading test. In the control groups, the failure occurred at the bone-implant interface, in the BAG group the failure occurred mainly in the reacted glass. The implants coated with BAG were integrated into host bone without a connective tissue capsule and were surrounded by significantly more bone than the control implants. The findings indicate clearly that the use of CO2 laser radiation to create BAG coatings did not inhibit the bioactive properties of the glass in terms of osteoconduction.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (39)

Show source-provided references
1. R. A. JAFFIN and C. L. BERMAN, J. Periodontol. 62 (1991) 2.10.1902/jop.1991.62.1.2 ↗
2. C. W. ULM, P. SOLAR, B. GISELLMANN, M. MALEJKA and G. WATZEK, Int. J. Oral. Maxillofac. Surg. 24 (1995) 279.10.1016/S0901-5027(95)80029-8 ↗
3. L. G. CHEUNG and A. C. LEUNG, J. Oral Maxillofac. Surg. 61 (2003) 1263.10.1016/S0278-2391(03)00726-2 ↗
4. J. ROTGER and R. ELSON, Clin. Orthop. 211 (1986) 154.
5. J. DUPARC and P. MASSIN, J. Bone Joint Surg. Br. 74 (1992) 251.10.1302/0301-620X.74B2.1544963 ↗
6. K. SOBALLE, S. OVERGAARD, E. S. HANSEN, H. BROKSTEDT-RASMUSSEN, M. LIND and C. BUNGER, J. Long Term Eff. Med. Implants 9 (1999) 131.
7. Annual Industry Report, Implant Dent. 2 (2003) 108.
8. L. L. HENCH, R. J. SPLINTER, W. C. ALLEN and T. K. GREENLEE, J. Biomed. Mater. Res. 5 (1971) 117.10.1002/jbm.820050611 ↗
9. D. F. WILLIAMS, in “Definitions in Biomaterials”, Proceedings of a Consensus Conference of the European Society for Biomaterials Chester, vol. 4, England, UK, 1986 (Elsevier, Amsterdam, 1987) pp. 24, 28 and 64.
10. L. L. HENCH and ö. H. ANDERSSON, in “An Introduction to BIOCERAMICS. Advanced Series in Ceramics,” vol. 1 (World Scientific, Singapore, 1993), pp. 41-62.10.1142/9789814317351_0003 ↗
11. A. ITäLä, E. G. NORDSTRöM, H. O. YLäNEN, H. T. ARO and M. HUPA, J. Biomed. Mater. Res. 56(2) (2001) 282.10.1002/1097-4636(200108)56:2<282::AID-JBM1096>3.0.CO;2-5 ↗
12. M. JOKINEN, T. PELTOLA, J. SIMOLA, J. KORVENTAUSTA and A. YLI-URPO, in “Proceedings of the 13th International Symposium on Ceramics in Medicine”, Key Eng. Mater. 192–195 (2001) 601.
13. M. PEREIRA and L. L. HENCH, J. Sol-Gel Sci. Techol. 7 (1996) 59.10.1007/BF00401884 ↗
14. P. DUCHEYNE, A. EL-GHANNAM and I. SHAPIRO, J. Cell Biochem. 56 (1994) 162.10.1002/jcb.240560207 ↗
15. ö. H. ANDERSSON, G. LIU, K. H. KARLSSON, L. NIEMI, J. MIETTINEN and J. JUHANOJA, J. Mater. Sci.: Mater. Med. 1 (1990) 219.
16. T. KOKUBO, H. KUSHITANI, S. SAKKA, T. KITSUGI and T. YAMAMURO, J. Biomed. Mater. Res. 24 (1990) 721.10.1002/jbm.820240607 ↗
17. C. LOTY, J. M. SAUTIER, M. T. TAN, M. OBOEUF, E. JALLOT, H. BOULEKBACHE, D. GREENSPAN and N. FOREST, J. Bone Miner. Res. 16 (2001) 231.10.1359/jbmr.2001.16.2.231 ↗
18. E. SUOMINEN, in “Bioactive Ceramics in Reconstruction of Bone Defects. Academic Dissertation” (University of Turku, Turku, 1996) pp. 33-55.
19. J. HEIKKILä, H. AHO, A. YLI-URPO, R.-P. HAPPONEN and A. AHO, Acta Orthop. Scand. 66 (1995) 463.10.3109/17453679508995588 ↗
20. T. TURUNEN, J. PELTOLA, H. HELENIUS, A. YLI-URPO and R.-P. HAPPONEN, Clin. Oral Implants Res. 8 (1997) 96.10.1034/j.1600-0501.1997.080204.x ↗
21. M. PELTOLA, K. ATASALO, J. SUONPää, A. YLI-URPO and P. LAIPPALA, J. Biomed. Mater. Res. (Appl. Biomater.) 58 (2001) 261.10.1002/1097-4636(2001)58:3<261::AID-JBM1015>3.0.CO;2-7 ↗
22. K. J. PAJAMäKI, T. S. LINDHOLM, ö. H. ANDERSSON, K. H. KARLSSON, E. VEDEL, A. YLI-URPO and R. P. HAPPONEN, J. Mater. Sci.: Mater. Med. 6 (1995) 14.
23. L. L. HENCH and ö. H. ANDERSSON, in “An Introduction to BIOCERAMICS. Advanced Series in Ceramics”, vol. 1 (World Scientific, Singapore, 1993) pp. 239-260.10.1142/9789814317351_0013 ↗
24. ö. H. ANDERSSON, K. H. KARLSSON, H. HERO, E. VEDEL, A. YLI-URPO, K. J. J. PAJAMäKI and T. S. LINDHOLM, J. Mater. Sci.: Mater. Med. 6 (1995) 242.
25. J. HAUTANIEMI, H. HERO and J. JUHANOJA, ibid. 3 (1992) 186.
26. N. MORITZ, E. VEDEL, H. YLäNEN, M. JOKINEN, M. HUPA and A. YLI-URPO, in “Proceedings of the 15th International Symposium On Ceramics in Medicine”, Key Eng. Mat. 240–242 (2003) 221.
27. E. VEDEL, N. MORITZ, H. YLäNEN, M. JOKINEN, A. YLI-URPO and M. HUPA, in “Proceedings of the 15th International Symposium On Ceramics in Medicine”, Key Eng. Mater. 240–242 (2003) 225.
28. M. BRINK, J. Biomed. Mater. Res. 36 (1997) 109.10.1002/(SICI)1097-4636(199707)36:1<109::AID-JBM13>3.0.CO;2-D ↗
29. M. BRINK, T. TURUNEN, R.-P. HAPPONEN and A. YLI-URPO, ibid. 37 (1997) 114.10.1002/(SICI)1097-4636(199710)37:1<114::AID-JBM14>3.0.CO;2-G ↗
30. W. M. STEEN, in “Laser Materials Processing” (Springer-Verlag, London, 1991).10.1007/978-1-4471-3820-4 ↗
31. T. CHIA, L. L. HENCH, C. QIN and C. K. HSIEH, Mat. Res. Soc. Symp. Proc. 190 (1990) 819.10.1557/PROC-180-819 ↗
32. H.-M. KIM, F. MIYAJI, T. KOKUBO and T. NAKAMURA, J. Biomed. Mater. Res. 32 (1996) 409.10.1002/(SICI)1097-4636(199611)32:3<409::AID-JBM14>3.0.CO;2-B ↗
33. H.-M. KIM, T. KOKUBO, S. FUJIBAYASHI, S. NISHIGUCHI and T. NAKAMURA, ibid. 52 (2000) 553.10.1002/1097-4636(20001205)52:3<553::AID-JBM14>3.0.CO;2-X ↗
34. H. TAKADAMA, H.-M. KIM, T. KOKUBO and T. NAKAMURA, ibid. 57 (2001) 441.10.1002/1097-4636(20011205)57:3<441::AID-JBM1187>3.0.CO;2-B ↗
35. F. AKIN, H. ZREIQAT, S. JORDAN, M. B. J. WIJESUNDARA and L. HANLEY, ibid. 57 (2001) 588.10.1002/1097-4636(20011215)57:4<588::AID-JBM1206>3.0.CO;2-Y ↗
36. J. T. HEIKKILä, N. BELIAEV, A. YLI-URPO and A. AHO, in “Proceedings of the 8th International Symposium On Ceramics in Medicine” (Pergamon/Elsevier, 1995) p. 505.
37. Y. H. AN, W. R. BARFIELD and I. KNETS, in “Mechanical Testing of Bone and Bone-Implant Interface” (CRC Press, Boca Raton, FL, 2000) pp. 103-118.
38. N. MORITZ, M. JOKINEN, T. PELTOLA, S. AREVA and A. YLI-URPO, J. Biomed. Mater. Res. 65A (2003) 9.10.1002/jbm.a.10434 ↗
39. T. PELTOLA, H. PALDAN, N. MORITZ, S. AREVA, J. KORVENTAUSTA, M. JOKINEN, T. NäRHI, R. P. HAPPONEN and A. YLI-URPO, in “Proceedings of the 15th International Symposium On Ceramics in Medicine”, Key Eng. Mater. 218–220 (2002) 207.