journal article·2000-02

Load-bearing behavior of a simulated craniofacial structure fabricated from a hydroxyapatite cement and bioresorbable fiber-mesh

A. S. Von Gonten, J. R. Kelly, J. M. Antonucci

Publisher page

Abstract

Calcium phosphate cements (CPC) have proven successful in the repair of small, non-stress bearing skeletal defects. These cements do not have sufficient tensile strength or fracture toughness to allow their use in stress-bearing applications. It was hypothesized that a bioresorbable fiber mesh would improve the load-bearing behavior of shell structures fabricated of CPC. This study used a biaxial flexure fixture to compare the work-to-fracture values of discs made of: (1) CPC; (2) CPC reinforced with a bioresorbable two-dimensionally oriented poly(glactin) fiber-mesh; and (3) poly(methyl methacrylate) (PMMA) that were immersed in a serum-like solution for 0-28 days. CPC-mesh and PMMA discs were indistinguishable at 0, 1 and 7 days, based on work-to-fracture data. CPC and CPC-mesh discs were indistinguishable at day 28, because of fiber hydrolysis. The knitted fiber-mesh was effective in improving load-bearing behavior of a calcium phosphate cement for potential structural repair of bone defects.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (18)

Show source-provided references
1. D. G. Kline, Arch. Surg. 91 (1965) 924.10.1001/archsurg.1965.01320180058014 ↗
2. C. E. Nussbaum, P. K. Maurer and J. V. Mcdonald, J. Neurosurg. 71 (1989) 124.10.3171/jns.1989.71.1.0124 ↗
3. J. Beumer, D. N. Firtell and T. A. Curtis, J. Prosthet. Dent. 42 (1979) 67.10.1016/0022-3913(79)90332-9 ↗
4. J. F. Ronderos, D. A. Wiles and F. A. Ragan et al., Surg. Neurol. 37 (1992) 356.10.1016/0090-3019(92)90003-6 ↗
5. P. D. Costantino, C. D. Friedman, K. Jones, L. C. Chow and G. A. Sisson, Plast. Reconstr. Surg. 90 (1992) 174.10.1097/00006534-199290020-00003 ↗
6. P. D. Costantino and C. D. Friedman, Otolaryngol. Clin. North Amer. 27 (1994) 1037.10.1016/S0030-6665(20)30622-8 ↗
7. S. Isaksson, Swed. Dent. J. Suppl. 84 (1992) 1.
8. P. W. Brown and B. Constantz, in Proceedings, Materials Research Society Meeting, San Francisco, CA, April 13-15, 1993, (CRC Press, Boca Raton, 1994) p. 127.
9. L. C. Chow, S. Takagi, P. D. Costantino and C. D. Friedman, Mater. Res. Soc. Symp. Proc. 179 (1991) 3.
10. Y. Fukase, E. D. Eanes, S. Takagi, L. C. Chow and W. E. Brown, J. Dent. Res. 69 (1990) 1852.10.1177/00220345900690121201 ↗
11. P. K. Maurer and J. V. Mcdonald, J. Neurosurg. 63 (1985) 448.10.3171/jns.1985.63.3.0448 ↗
12. B. Vallfors, H-A. Hansson and J. Svensson, J. Neurosurg. ibid. 9 (1981) 407.10.1227/00006123-198110000-00011 ↗
13. A. G. Evans and D. B. Marshall, Acta Metall. 37 (1989) 2567.10.1016/0001-6160(89)90291-5 ↗
14. D. K. Shetty, A. R. Rosenfield, P. Mcguire, G. K. Bansal and W. H. Duckworth, Ceram. Bull. 159 (1980) 1193.
15. G. D. Quinn, J. Salem, I. Bar-on, K. Cho, M. Foley and H. Fang, J. Res. Natl. Inst. Stand. Technol. 97 (1992) 579.10.6028/jres.097.026 ↗
16. J. R. Kelly, Dent. Mater. 11 (1995) 103.10.1016/0109-5641(95)80043-3 ↗
17. C. C. Chu, Ann. Surg. 195 (1982) 55.10.1097/00000658-198201001-00009 ↗
18. P. H. Craig, J. A. Williams and K. W. Davis et al., Surg. Gynecol. Obstet. 141 (1975) 1.