Differences between the wear couples metal-on-polyethylene and ceramic-on-ceramic in the stability against dislocation of total hip replacement
Source abstract
Abstract
After total hip replacement an insufficient range of motion (ROM) can lead to contact between femoral neck and rim of the cup (= impingement) causing dislocation and consecutive material failure. The purpose of this study was to analyse the influence of different wear couples on the ROM and stability against dislocation. By means of a special testing device the ROM until impingement, the ROM until dislocation as well as the resisting moment against levering the head out of the cup were experimentally determined. Various total hip systems with cup inserts made of ceramic and polyethylene were comparatively examined in different implant positions. Maximum resisting moment as well as the ROM until impingement and dislocation were clearly influenced by the implant position. Furthermore, the stability against dislocation was affected by design parameters, whereas in the case of appropriate implant position differing wear couples (metal-on-polyethylene vs. ceramic-on-ceramic) had a minor impact. However, as shown by tests under lubricant conditions, ceramic-on-ceramic couples provided less dislocation stability in unfavourable implant position in comparison to metal-on-polyethylene. Therefore, ceramic-on-ceramic couples should only be applied in the case of optimised implant orientation preventing impingement and dislocation with subsequent material failure like chipping off or breakage.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (25)
Show source-provided references
1. J. D'Antonio, W. Capello, M. Manley and B. Bierbaum, J. Arthroplasty 17 (2002) 390.10.1054/arth.2002.32183 ↗
2. P. Herberts and H. Malchau, Acta Orthop. Scand. 71 (2000) 111.10.1080/000164700317413067 ↗
3. H. Oonishi, H. Amino, M. Ueno and H. Yunoki, in “Reliability and Long-term Results of Ceramics in Orthopaedics”, edited by L. Sedel and G. Willmann (Georg Thieme, Stuttgart, 1999) p. 7.
4. J. P. Garino, in “Bioceramics in Joint Arthroplasty”, edited by H. Zippel and M. Dietrich (Steinkopf, Darmstadt, 2003) p. 215.10.1007/978-3-642-85763-8_35 ↗
5. B. E. Bierbaum, J. Nairus, D. Kuesis, J. C. Morrison and D. Ward, Clin. Orthop. 405 (2002) 158.10.1097/00003086-200212000-00019 ↗
6. R. J. Bader, E. Steinhauser, G. Willmann and R. Gradinger, Hip Int. 11 (2001) 80.10.1177/112070000101100203 ↗
7. R. L. Barrack and T. P. Schmalzried, J. Bone Joint Surg. 84-A (2002) 1218.10.2106/00004623-200207000-00021 ↗
8. D. E. McCollum and W. J. Gray, Clin. Orthop. 261 (1990) 159.10.1097/00003086-199012000-00019 ↗
9. J. Sanchez-Sotelo and D. J. Berry, Orthop. Clin. North Am. 32 (2001) 543.10.1016/S0030-5898(05)70225-X ↗
10. G. M. Robbins, B. A. Masri, D. S. Garbuz, N. Greidanus and C. P. Duncan, Orthop. Clin. North Am. 32 (2001) 593.10.1016/S0030-5898(05)70230-3 ↗
11. D. Kohn, O. Rührmann and C. J. Wirth, Z. Orthop. 135 (1997) 40.10.1055/s-2008-1039553 ↗
12. C. Lavernia, R. Barrack, R. Thornberry and E. Tozakoglou, Scientific exhibit presented at 68th AAOS Meeting, New Orleans, LA, 1998.
13. R. Bader, R. Scholz, E. Steinhauser and W. Mittelmeier, Orthopädische Praxis 39 (2003) 430.
14. G. Bergmann, F. Graichen and A. Rohlmann, J. Biomech 6 (1994) 969.
15. F. J. Kummer, S. Shah, S. Iyer and P. E. Dicesare, J. Arthroplasty 14 (1999) 509.10.1016/S0883-5403(99)90110-9 ↗
16. R. Y. G. Woo and B. F. Morrey, J. Bone Joint Surg. 64-A (1982) 1295.10.2106/00004623-198264090-00004 ↗
17. B. F. Morrey, Orthop. Clin. North Am. 23 (1992) 237.10.1016/S0030-5898(20)31734-X ↗
18. J. G. Kennedy, W. B. Rogers, K. E. Soffe, R. J. Sullivan, D. G. Griffen and L. J. Sheehan, J. Arthroplasty 13 (1998) 530.10.1016/S0883-5403(98)90052-3 ↗
19. J. E. Nevelos, E. Ingham, C. Doyle, A. B. Nevelos and J. Fisher, J. Mater. Sci. 12 (2001) 141.
20. C. F. Scifert, P. C. Noble, T. D. Brown, R. L. Bartz, N. Kadakia, N. Sugano, R. C. Johnston, D. R. Pedersen and J. J. Callaghan, Orthop. Clin. North Am. 32 (2001) 553.10.1016/S0030-5898(05)70226-1 ↗
21. R. Klabunde and C. Jäggi, in “World Tribology Forum in Arthroplasty”, edited by C. Rieker, S. Oberholzer and U. Wyss (Hans Huber, Bern, 2000) p. 295.
22. G. Willmann, Biomed. Tech. 46 (2001) 343.10.1515/bmte.2001.46.12.343 ↗
23. A. Toni, S. Stea, B. Bordini and A. Sudanese, in “Bioceramics in Joint Arhroplasty”, edited by J. Garino and G. Willmann (Georg Thieme, Stuttgart, 2002) p. 75.
24. G. E. Lewinnek, J. L. Lewis, R. Tarr, C. L. Compere and J. R. Zimmerman, J. Bone Joint Surg. 60-A (1978) 217.10.2106/00004623-197860020-00014 ↗
25. R. J. Beaver, C. McCormick and A. Kop, in “Bioceramics in Joint Arhroplasty”, edited by J. Garino and G. Willmann (Georg Thieme, Stuttgart, 2002) p. 65.