In vivo biocompatibility of two PEG/PAA interpenetrating polymer networks as corneal inlays following deep stromal pocket implantation
Source abstract
Abstract
This study compared the effects of implanting two interpenetrating polymer networks (IPNs) into rabbit corneas. The first (Implant 1) was based on PEG-diacrylate, the second (Implant 2) was based on PEG-diacrylamide. There were inserted into deep stromal pockets created using a manual surgical technique for either 3 or 6 months. The implanted corneas were compared with normal and sham-operated corneas through slit lamp observation, anterior segment optical coherence tomography, in vivo confocal scanning and histological examination. Corneas with Implant 1 (based on PEG-diacrylate) developed diffuse haze, ulcers and opacities within 3 months, while corneas with Implant 2 (based on PEG-diacrylamide) remained clear at 6 months. They also exhibited normal numbers of epithelial cell layers, without any immune cell infiltration, inflammation, oedema or neovascularisation at post-operative 6 month. Morphological studies showed transient epithelial layer thinning over the hydrogel inserted area and elevated keratocyte activity at 3 months; however, the epithelium thickness and keratocyte morphology were improved at 6 months. Implant 2 exhibited superior in vivo biocompatibility and higher optical clarity than Implant 1. PEG-diacrylamide-based IPN hydrogel is therefore a potential candidate for corneal inlays to correct refractive error.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Corneal surgery and disorders · Ocular Surface and Contact Lens · Corneal Surgery and Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (37)
Show source-provided references
1. Solomon KD, de Fernandez Castro LE, Sandoval HP, Biber JM, Groat B, Neff KD, Ying MS, French JW, Donnenfeld ED, Lindstorm RL. JointLasik Study Task Force. LASIK world literature review: quality of life and patient satisfaction. Ophthalmology. 2009;116:691–701.10.1016/j.ophtha.2008.12.037 ↗
2. Caster AI, Trattler W. Corneal ectasia after laser vision correction. Int Ophthalmol Clin. 2008;48:73–81.10.1097/IIO.0b013e31815efc65 ↗
3. Binder PS. Analysis of ectasia after laser in situ keratomileusis: risk factors. J Cataract Refract Surg. 2007;33:1530–8.10.1016/j.jcrs.2007.04.043 ↗
4. Klein SR, Epstein RJ, Randleman JB, Stulting RD. Corneal ectasia after laser in situ keratomileusis in patients without apparent preoperative risk factors. Cornea. 2006;25:388–403.10.1097/01.ico.0000222479.68242.77 ↗
5. Sweeney DF, Vannas A, Hughes TC, Evans MD, McLean KM, Xie RZ, Pravin VK, Prakasam RK. Vision Inlay team. Synthetic corneal inlays. Clin Exp Optom. 2008;91:56–66.10.1111/j.1444-0938.2007.00198.x ↗
6. Barraquer J. Querataplastia refractive: studios e infomaciones oftalmologicas. 1949;2:1–21.
7. Choyce DP. The correction of refractive errors with polysulfone corneal inlays. A new frontier to be explored? Trans ophthalmol soc U. K. 1985;104:332–42.
8. Mester U, Roth K, Mu D. Versvchemit 2-hydroxyaethylmethycrylatlinsen als keratophakiematerial. Ber Ophthalmol Ges. 1972;72:326.10.1007/978-3-642-47088-2_59 ↗
9. McCarey BE, Andrews DM. Refractive keratoplasty with intrastromal hydrogel lenticular implants. Invest Ophthalmol Vis Sci. 1981;21:107–15.
10. Dupont D, Gravagna P, Albinet P, Tayot JL, Romanet JP, Mouillon M. Biocompatibility of human collagen type IV intracorneal implants. Cornea. 1989;8:251–8.10.1097/00003226-198912000-00005 ↗
11. Lekskul M, Burrows R, Kublin CL, Cintron C. CxGELSIX: a novel preparation of type VI collagen with possible use as a biomaterial. Cornea. 2000;19:194–203.10.1097/00003226-200003000-00013 ↗
12. Oh’Eineachin R. New synthetic lenticule produces good results in hyperopic patients. European Times. 2000;9:53.
13. Xie RZ, Evans MD, Bojarski B, Hughes TC, Chan GY, Nguyen X, Wilkie JS, McLean KM, Vannas A, Sweeney DF. Two-year preclinical testing of perfluoropolyether polymer as a corneal inlay. Invest Ophthalmol Vis Sci. 2006;47:574–81.10.1167/iovs.05-0872 ↗
14. Beekhuis WH, McCarey BE, van Rij G, Waring GO. Complications of hydrogel intracorneal lenses in monkeys. Arch Ophthalmol. 1987;105:116–22.10.1001/archopht.1987.01060010122043 ↗
15. McCarey BE, Lane SS, Lindstrom RL. Alloplastic corneal lenses. Int Ophthalmol Clin. 1988;28:155–64.10.1097/00004397-198802820-00009 ↗
16. Evans MDM, Sweeney DF. Synthetic corneal implants. In: Traian C, editor. Biomaterials and Regenerative Medicine in Ophthalmology. Cambridge: Woodhead Publishing; 2010. p. 65–133.10.1533/9781845697433.1.65 ↗
17. Evans MDM, McLean KM, Hughes TC, Sweeney DF. The development of a synthetic onlay for the correction of refractive error. Biomats. 2001;22:3319–28.10.1016/S0142-9612(01)00169-7 ↗
18. Myung D, Duhamel PE, Cochran JR, Noolandi J, Ta CN, Frank CW. Development of hydrogel-based keratoprostheses: a materials perspective. Biotechnol Prog. 2008;24:735–41.10.1021/bp070476n ↗
19. Myung D, Koh W, Bakri A, Zhang F, Marshall A, Ko J, Noolandi J, Carrasco M, Cochran JR, Frank CW, Ta CN. Design and fabrication of an artificial cornea based on a photolithographically patterned hydrogel construct. Biomed Microdevices. 2007;9:911–22.10.1007/s10544-006-9040-4 ↗
20. Cruise GM, Scharp DS, Hubbell JA. Characterization of permeability and network structure of interfacially photopolymerized poly(ethylene glycol) diacrylate hydrogels. Biomaterials. 1998;19:1287–94.10.1016/S0142-9612(98)00025-8 ↗
21. Myung D, Koh W, Ko J, Hu Y, Carrassio M, Noolandi J, Frank CW, Ta CN. Biomimetic strain hardening in interpenetrating polymer network hydrogels. Polymer. 2007;48:5376–87.10.1016/j.polymer.2007.06.070 ↗
22. Myung D, Farooqui N, Waters D, Schaber S, Koh W, Carrasco M, Noolandi J, Frank CW, Ta CN. Glucose-permeable interpenetrating polymer network hydrogels for corneal implant applications: a pilot study. Curr Eye Res. 2008;33:29–43.10.1080/02713680701793930 ↗
23. Hartmann L, Watanabe K, Zheng LL, Kim CY, Beck SE, Huie P, Noolandi J, Cochran JR, Ta CN, Frank CW. Toward the development of an artificial cornea: improved stability of interpenetrating polymer networks. J Biomed Mater Res B Appl Biomater. 2011;98:8–17.10.1002/jbm.b.31806 ↗
24. He J, Bazan NG, Bazan HE. Mapping the entire human corneal nerve architecture. Exp Eye Res. 2010;91:513–23.10.1016/j.exer.2010.07.007 ↗
25. Muller LJ, Marfurt CF, Kruse F, Tervo TM. Corneal nerves: structure, contents and function. Exp Eye Res. 2003;76:521–42.10.1016/S0014-4835(03)00050-2 ↗
26. Evans MD, Prakasam RK, Vaddavalli PK, Hughes TC, Knower W, Wilkie JS, McLean KM, Johnson G, McFarland GA, Xie RZ, Sweeney DF. A perfluoropolyether corneal inlay for the correction of refractive error. Biomaterials. 2011;32:3158–65.10.1016/j.biomaterials.2011.01.047 ↗
27. Yilmaz OF, Alagoz N, Pekel G, Azman E, Aksoy EF, Cakir H, Bozkurt E, Demirok A. Intracorneal inlay to correct presbyopia: long-term results. J Cataract Refract Surg. 2011;37:1275–81.10.1016/j.jcrs.2011.01.027 ↗
28. Calvillo MP, McLaren JW, Hodge DO, Bourne WM. Corneal reinnervation after LASIK: prospective 3-year longitudinal study. Invest Ophthalmol Vis Sci. 2004;45:3991–6.10.1167/iovs.04-0561 ↗
29. Larrea X, De Courten C, Feingold V, Burger J, Buchler P. Oxygen and glucose distribution after intracorneal lens implantation. Optom Vis Sci. 2007;84:1074–81.10.1097/OPX.0b013e31815b9dd6 ↗
30. Angunawela RI, Riau AK, Chaurasia SS, Tan DT, Mehta JS. Refractive lenticule re-implantation after myopic ReLEx: a feasibility study of stromal restoration after refractive surgery in a rabbit model. Invest Ophthalmol Vis Sci. 2012;53:4975–85.10.1167/iovs.12-10170 ↗
31. Roth N. Relationship between corneal radius of curvature and age in rabbits. Br Vet J. 1969;125:560–3.10.1016/S0007-1935(17)48658-1 ↗
32. Kim P, Sutton GL, Rootman DS. Applications of the femtosecond laser in corneal refractive surgery. Curr Opin Ophthalmol. 2011;22:238–44.10.1097/ICU.0b013e3283477c9c ↗
33. Dexl AK, Seyeddain O, Riha W, Hohensinn M, Ruckl T, Reischl V, et al. One-year visual outcomes and patient satisfaction after surgical correction of presbyopia with an intracorneal inlay of a new design. J Cataract Refract Surg. 2011;38:262–9.10.1016/j.jcrs.2011.08.031 ↗
34. Bouzoukis DI, Kymionis GD, Limnopoulou AN, Kounis GA, Pallikaris IG. Femtosecond laser-assisted corneal pocket creation using a mask for inlay implantation. J Refract Surg. 2011;27:818–20.10.3928/1081597X-20110706-01 ↗
35. Ruiz LA, Cepeda LM, Fuentes VC. Intrastromal correction of presbyopia using a femtosecond laser system. J Refract Surg. 2009;25:847–54.10.3928/1081597X-20090917-05 ↗
36. Mulet ME, Alio JL, Knorz MC. Hydrogel intracorneal inlays for the correction of hyperopia: outcomes and complications after 5 years of follow-up. Ophthalmology. 2009;116:1455–60.10.1016/j.ophtha.2009.05.019 ↗
37. Kanellopoulos AJ. Collagen cross-linking in early keratoconus with riboflavin in a femtosecond laser-created pocket: initial clinical results. J Refract Surg. 2009;25:1034–7.10.3928/1081597X-20090901-02 ↗