In vitro microhardness of glass ionomer cements
Source abstract
Abstract
This study evaluated the surface microhardness of four glass ionomer cements and a composite resin (Fuji IX, Ketac Molar, Vidrion R, Vitromolar and Z 250). Ten specimens of each glass ionomer cement with 8.0 mm diameter and 5.0 mm high dimensions were made and Vicker's microhardness measurements were taken at 1 day and 1 week after initial setting reaction. The results were analyzed using Student's T test and Tukey test (p < 0.05) and demonstrated that the values of microhardness increased after 1 week, with the exception of Fuji IX. Resin composite Z250 presented the greatest values for microhardness.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. J. E. FRENCKEN, Y. SONGPAISAN, P. PHANTUMVANIT and T. PILOT, Int. Dent. J. 44 (1994) 460.
2. J. E. FRENCKEN, T. PILOT, Y. SONGPAISAN and P. PHANTUMVANIT, J. Public Health Dent. 56 (1996) 135.10.1111/j.1752-7325.1996.tb02423.x ↗
3. H. YIP, R. SMALES, C. YU, X. GAO and D. DENG, Quintessence Int. 33 (2002) 17.
4. J. E. FRENCKEN, F. MAKONI and W. D. SITHOLE, Community Dent. Oral Epidemiol. 26 (1998) 372.10.1111/j.1600-0528.1998.tb01975.x ↗
5. J. E. FRENCKEN and C. J. HOLMGREN, Community Dent. Oral Epidemiol. 27 (1999) 423.10.1111/j.1600-0528.1999.tb02043.x ↗
6. S. MICKENAUTSCH, I. MUNSHI and E. S. GROSSMAN, SADJ 57 (2002) 52.
7. C. S TOI, M. BONECKER and P. E. CLEATON-JONES, Oral Microbiol. Immunol. 18 (2003) 160.10.1034/j.1399-302X.2003.00051.x ↗
8. A. D. WILSON and B. E. KENT, Br. Dent. J. 132 (1972) 133.10.1038/sj.bdj.4802810 ↗
9. A. U. J. YAP, Y. S. PEK and P. CHEANG, J. Oral Rehabil. 30 (2003) 1.10.1046/j.1365-2842.2003.01006.x ↗
10. T. BASTING, M. C. SERRA and J. R. RODRIGUES, J. Oral Rehabil. 29 (2002) 1187.10.1046/j.1365-2842.2002.00906.x ↗
11. J. B. B. C. LEITE, in “Estudo comparativo da dureza superficial de cimentos ionoméricos restauradores submetidos à condições de umidade e dessecamento” (Dissertação Mestrado, Araraquara: Faculdade de Odontologia, 1997).
12. K. J. ANUSAVICE, in “Phillips” Science of dental materials” (W. B. Saunders, USA, 1996) 10th ed.
13. L. FORSTEN, Biomaterials 19 (1998) 503.10.1016/S0142-9612(97)00130-0 ↗
14. N. EWOLDSEN, D. COVEY and M. LAVIN, Spec. Care Dent. 17 (1997) 19.10.1111/j.1754-4505.1997.tb00531.x ↗
15. J. ELLAKURIA, R. TRIANA, N. MÍNGUEZ, I. SOLER, G. IBASETA, J. MAZA and F. GARCIA-GODOY, Dent. Mater. 19 (2003) 286.10.1016/S0109-5641(02)00042-8 ↗
16. Y. MOMOI, K. HIROSAKI, A. KOHNO and J. F. MCCABE, Dent. Mater. 13 (1997) 82.10.1016/S0109-5641(97)80016-4 ↗
17. A. PEUTZFELDT, F. GARCIA-GODOY and E. ASMUSSEN, Am. J. Dent. 10 (1997) 15.
18. A. U. J. YAP, S. H. TEOH, G. W. HASTINGS and C. S. LU, J. Oral Rehabil. 24 (1997) 574.10.1046/j.1365-2842.1997.00528.x ↗
19. R. J. SMALES, D. A. WEBSTER and P. I. LEPPARD, J. Dent. 20 (1992) 215.10.1016/0300-5712(92)90082-N ↗
20. L. H. MAIR, T. A. STOLARSKI, R. W. VOWLES and C. H. LLOYD, J. Dent. 24 (1996) 141.10.1016/0300-5712(95)00043-7 ↗