Abstract

This study presents the microstructural and mechanical behavior of the CF/PA12 composite material developed as well as its biomechanical performance when used for the fabrication of femoral stems. The static tests were performed to evaluate the compressive and flexural modulus as well as the ultimate compressive and bending strength. It was found that CF/PA12 composite had bone-matching properties in the same order of magnitude as cortical bone in the femur. Density and void content measurements were also done to assess the consolidation quality. Dynamic fatigue testing was conducted on both CF/PA12 cylinders and femoral stems to evaluate the long term durability and mechanical reliability of the composite. Compression-compression cyclic loading was used at a frequency of 6 Hz with loads varying between 17 kN and 22 kN for the composite cylinders while a frequency of 10 Hz and load of 2300 N was employed for the femoral stems. Results indicate that the fatigue performance of CF/PA12 composite surpasses by far the required fatigue performance for total hip prosthesis (THP) stems. The overall performance of the CF/PA12 femoral stems confirms that this composite is an excellent candidate material for orthopedic applications such as THP stems.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Orthopedic Infections and Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. S. KURTZ, E. LAU, K. ZHAO, F. MOWAT, K. ONG, and M. HALPERN, in 73rd Annual Meeting of the American Academy of Orthopaedic Surgeons (Chicago, IL, 2006)
2. D. TAYLOR, C. MARTIN, B. CORNELIS and M. E. B. JONES, J. Eng. Med. 207(2) (1993) 12110.1243/PIME_PROC_1993_207_280_02 ↗
3. H. BOUGHERARA, M. N. BUREAU, M. CAMPBELL, A. VADEAN and L’H. YAHIA, J. Biomed. Mater. Res. A. 82A(1) (2007) 2710.1002/jbm.a.31146 ↗
4. A. REINHARDT, S. G. ADVANI, M. H. SANTARE and F. MILLER, J. Compos. Mater. 33(9) (1999) 85310.1177/002199839903300904 ↗
5. J. A. SIMOES and A. T. MARQUES, Comp. Sci. Tech. 60 (2000) 55910.1016/S0266-3538(99)00155-4 ↗
6. J. A. SIMOES and A. T. MARQUES, Compos. Part A 32 (2001) 65510.1016/S1359-835X(00)00157-3 ↗
7. J. A. SIMOES and A. T. MARQUES, Mater. Des. 26 (2005) 39110.1016/j.matdes.2004.07.024 ↗
8. F. K. CHANG, J. L. PEREZ and J. A. DAVIDSON, J. Biomed. Mater. Res. 24(7) (1990) 87310.1002/jbm.820240707 ↗
9. R. DE SANTIS, L. AMBROSIO and L. NICOLAIS, J. Inorg. Biochem. 79(1–4) (2000) 9710.1016/S0162-0134(99)00228-7 ↗
10. F. ADAM, D. S. HAMMER, S. PFAUTSCH and K. WESTERMANN, J. Arthroplasty 17(2) (2002) 21710.1054/arth.2002.30285 ↗
11. M. AKAY and N. ASLAN, J. Biomed. Mater. Res. 31 (1996) 16710.1002/(SICI)1097-4636(199606)31:2<167::AID-JBM3>3.0.CO;2-L ↗
12. J. R. BRITTON, C. G. C. LYONS and P. J. PRENDERGAST, Strain 40 (2004) 19310.1111/j.1475-1305.2004.00167.x ↗
13. J.-G. LEGOUX, F. CHELLAT, R. LIMA, B. MARPLE, M. N. BUREAU, H. SHEN and G. A. CANDELIERE, J. Thermal Spray Technol. 15(4) (2006) 629
14. K. CHOI and S. A. GOLDSTEIN, J. Biomech. 25(12) (1992) 137110.1016/0021-9290(92)90051-2 ↗
15. American Society for Testing and Materials, “ASTM D348-00”, Standard Test Methods for Rigid Tubes Used for Electrical Insulation
16. American Society for Testing and Materials, “ASTM D790-03”, Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials p. 6
17. American Society for Testing and Materials, “ASTM E2207–02”, Standard Practice for Strain-Controlled Axial-Torsional Fatigue Testing with Thin-walled Tubular Specimens
18. O. H. BASQUIN, in “Proceedings of the American Society for Testing and Materials”, Vol 10 (1910)
19. International Standard Organization, “ISO7206–4”, Implants for Surgery-Partial and Total Hip Joint Prostheses-Part 4: Determination of Endurance Properties of Stemmed Femoral Components
20. American Society for Testing and Materials, “ASTM F1612–95”, Standard Practice For Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components with Torsion
21. M. N. BUREAU and J. DENAULT, Comp. Sci. Tech. 64 (2004) 178510.1016/j.compscitech.2004.01.016 ↗
22. D. C. WIRTZ, N. SCHIFFERS, T. PANDORF, K. RADERMACHER, D. WEICHERT and R. FORST, J. Biomech. 33 (2000) 132510.1016/S0021-9290(00)00069-5 ↗
23. D. T. REILLY and A. H. BURSTEIN, J. Biomech. 8(6) (1975) 39310.1016/0021-9290(75)90075-5 ↗
24. D. T. REILLY, A. H. BURSTEIN and V. H. FRANKEL, J. Biomech. 7(3) (1974) 27110.1016/0021-9290(74)90018-9 ↗
25. S. M. SNYDER and E. SCHNEIDER, J. Orthop. Res. 9 (1991) 42210.1002/jor.1100090315 ↗
26. H. B. SKINNER, Orthopedics 14(3) (1991) 323
27. G. BERGMANN, F. GRAICHEN and A. ROHLMANN, J. Biomech. 26(8) (1993) 96910.1016/0021-9290(93)90058-M ↗
28. American Society for Testing and Materials, “ASTM F1440–92”, Standard Practice for Cyclic Fatigue Testing of Metallic Stemmed Hip Arthroplasty Femoral Components Without Torsion