Corrosion behaviour of titanium after short-term exposure to an acidic environment containing fluoride ions
Source abstract
Abstract
The negative effect of fluoride ions on titanium has been known in dentistry for a long time. The presented work was aimed at the interaction between titanium and model saliva following a short-term exposure of a specimen to a model medical preparation rich in fluoride ions. The experimental work was carried out using titanium grade 2 in a physiological solution (pH non-adjusted, 5.8, 4.2; 5000 ppm F-) and in model saliva. Electrochemical measurement techniques were supplemented with XPS analysis. The presence of fluoride ions resulted in partial degradation of the passive layer even in a slightly acidic environment. The decrease of pH to the value of 4.2 and the presence of 5000 ppm F- caused titanium activation followed by a slow repassivation in model saliva. Formation of low soluble compound rich in fluorine explains experimental data. Short medical treatment can result in relatively long period of increased titanium corrosion.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Radiography and Imaging · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. Jones DA. Principles of prevention of corrosion. Upper Saddle River: Prentice Hall; 1995.
2. Cohen F, Chemla M, Burdairon G. Corrosive properties of odontologic fluoride-containing gels against titanium. Comptes Rendus de l’Academie des Sciences, Serie II. 1991;313:501–8.
3. Boere G. Influence of fluoride on titanium in an acidic environment measured by polarization resistance technique. J Appl Biomat. 1995;6:283–8.10.1002/jab.770060409 ↗
4. Johansson BI, Bergman B. Corrosion of titanium and amalgam couples: effect of fluoride, area size, surface preparation and fabrication procedures. Dent Mater. 1995;11:41–6.10.1016/0109-5641(95)80007-7 ↗
5. Kononen MH, Lavonius ET, Kivilahti JK. SEM observations on stress corrosion cracking of commercially pure titanium in a topical fluoride solution. Dent Mater. 1995;11:269–72.10.1016/0109-5641(95)80061-1 ↗
6. Toumelin-Chemla F, Rouelle F, Burdairon G. Corrosive properties of fluoride-containing odontologic gels against titanium. J Dent. 1996;24:109–15.10.1016/0300-5712(95)00033-X ↗
7. Ozeki K, Oda Y, Sumii T. The influence of fluoride prophylactic agents on the corrosion of titanium and titanium alloys. Shika Gakuho. 1996;96:293–304.
8. Strietzel R, Hosch A, Kalbfleisch H, Buch D. In vitro corrosion of titanium. Biomaterials. 1998;19:1495–9.10.1016/S0142-9612(98)00065-9 ↗
9. Arys A, Philippart C, Dourov N, He Y, Le QT, Pireaux JJ. Analysis of titanium dental implants after failure of osseointegration: combined histological, electron microscopy, and x-ray photoelectron spectroscopy approach. J Biomed Mater Res. 1998;43:300–12.10.1002/(SICI)1097-4636(199823)43:3<300::AID-JBM11>3.0.CO;2-J ↗
10. Joska L, Venclikova Z, Poddana M, Benada O. The mechanism of gingiva metallic pigmentations formation. Clin Oral Invest. 2009;13:1–7.10.1007/s00784-008-0206-8 ↗
11. Nakagawa M, Matsuya S, Shiraishi T, Ohta M. Effect of fluoride concentration and pH on corrosion behavior of titanium for dental use. J Dent Res. 1999;78:1568–72.10.1177/00220345990780091201 ↗
12. Fovet Y, Gal JY, Toumelin-Chemla F. Influence of pH and fluoride concentration on titanium passivating layer: stability of titanium dioxide. Talanta. 2001;53:1053–63.10.1016/S0039-9140(00)00592-0 ↗
13. Titanoff N, Manwell MA, Zameck RN, Grosso JE. Clinical and microbiological effects of daily brushing with either NaF or SnF2 gels in subjects with fixed or removable dental prostheses. J Clin Periodontol. 1989;16:284–90.10.1111/j.1600-051X.1989.tb01656.x ↗
14. Lindholm-Sethson B, Ardlin BI. Effects of pH and fluoride concentration on the corrosion of titanium. J Biomed Mater Res A. 2008;86A:149–59.10.1002/jbm.a.31415 ↗
15. Stájer A, Ungvári K, Pels IK. Corrosive effects of fluoride on titanium: Investigation by X-ray photoelectron spectroscopy, atomic force microscopy, and human epithelial cell culturing. J Biomed Mater Res A. 2008;87A:450–8.10.1002/jbm.a.31764 ↗
16. Marek M. The effect of tin in the Ag-Hg phase of dental amalgam on dissolution of mercury. Dent Mater. 1997;13:353–9.10.1016/S0109-5641(97)80106-6 ↗
17. CRC. Handbook of chemistry and physics. 89th ed, electronic ed. London: Taylor and Francis. http://www.hbcpnetbase.com/ (2008). Accessed 4 Feb 2009.
18. Orazem ME, Tribollet B. Electrochemical impedance spectroscopy. Hoboken: Wiley; 2008.10.1002/9780470381588 ↗
19. Barsoukov E, MacDonald R. Impedance spectroscopy: theory, experiment, and applications. 2nd ed. Hoboken: Wiley; 2005.10.1002/0471716243 ↗
20. Cottis B, Turgoose S. Corrosion testing made easy: impedance and noise analysis. Houston: NACE; 1999.
21. NIST. X-ray photoelectron spectroscopy database. Version 4.0. Gaithersburg: NIST. http://srdata.nist.gov/xps2 (2008). Accessed 8 Feb 2009.
22. James WJ, Johnson JW. Titanium, zirconium and hafnium. In: Bard AJ, Parsons R, Jordan J, editors. Standard potentials in aqueous solution. New York: Marcel Dekker; 1985. p. 539–47.
23. Pourbaix MJN. Atlas of electrochemical equilibriums in aqueous solutions. 2nd ed. Houston: NACE; 1974.
24. Al-Mayouf AM, Al-Swayih AA, Al-Mobarak NA. Effect of potential on the corrosion behavior of a new titanium alloy for dental implant applications in fluoride media. Mater Corros. 2004;55:88–94.10.1002/maco.200303697 ↗
25. Huang H-H. Effects of fluoride concentration and elastic tensile strain on the corrosion resistance of commercially pure titanium. Biomaterials. 2002;23:59–63.10.1016/S0142-9612(01)00079-5 ↗
26. Huang H-H. Effect of fluoride and albumin concentration on the corrosion behavior of Ti-6Al-4 V alloy. Biomaterials. 2003;24:275–82.10.1016/S0142-9612(02)00315-0 ↗
27. Mabilleau G, Bourdon S, Joly-Guillou ML, Filmon R, Basle MF, Chappard D. Influence of fluoride, hydrogen peroxide and lactic acid on the corrosion resistance of commercially pure titanium. Acta Biomater. 2006;2:121–9.10.1016/j.actbio.2005.09.004 ↗
28. Takemoto S, Hattori M, Yoshinari M, Kawada E, Oda Y. Corrosion behavior and surface characterization of titanium in solution containing fluoride and albumin. Biomaterials. 2004;26:829–37.10.1016/j.biomaterials.2004.03.025 ↗