journal article·2011-08

Electrodeposition of chitosan-glucose oxidase biocomposite onto Pt–Pb nanoparticles modified stainless steel needle electrode for amperometric glucose biosensor

Meiqing Guo, Haidong Fang, Rui Wang, Zhiqiang Yang, Xinhua Xu

Publisher page

Abstract

A glucose biosensor was fabricated by electrodepositing chitosan (CS)-glucose oxidase(GOD) biocomposite onto the stainless steel needle electrode (SSN electrode) modified by Pt-Pb nanoparticles (Pt-Pb/SSN electrode). Firstly, Pt-Pb nanoparticles were deposited onto the SSN electrode and then CS-GOD biocomposite was co-electrodeposited onto the Pt-Pb/SSN electrode in a mixed solution containing p-benzoquinone (p-BQ), CS and GOD. The electrochemical results showed that the Pt-Pb nanoparticles can accelerate the electron transfer and improve the effective surface area of the SSN electrode. As a result, the detection range of the proposed biosensor was from 0.03 to 9 mM with a current sensitivity of 0.4485 μA/mM and a response time of 15 s. The Michaelis constant value was calculated to be 4.9837 mM. The cell test results indicated that the electrodes have a low cytotoxicity. This work provided a suitable technology for the fabrication of the needle-type glucose biosensor.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. Pei JH, Tian F, Thundat T. Glucose biosensor based on the microcantilever. Anal Chem. 2004;76:292–7.10.1021/ac035048k ↗
2. Wilson GS, Hu YB. Enzyme based biosensors for in vivo measurements. Chem Rev. 2000;100:2693–704.10.1021/cr990003y ↗
3. Zhao W, Xu JJ, Shi CG, Chen HY. Multilayer membranes via layer-by-layer deposition of organic polymer protected Prussian blue nanoparticles and glucose oxidase for glucose biosensing. Langmuir. 2005;21:9630–4.10.1021/la051370+ ↗
4. Wang G, Mantey K, Nayfeh MH, Yau ST. Enhanced amperometric detection of glucose using Si-29 particles. Appl Phys Lett. 2006;89:243901.10.1063/1.2405384 ↗
5. Wang G, Yau ST, Mantey K, Nayfeh MH. Fluorescent Si nanoparticle-based electrode for sensing biomedical substances. Opt Commun. 2008;281:1765–70.10.1016/j.optcom.2007.07.070 ↗
6. Wu BY, Hou SH, Yin F, Zhao ZX, Wang YY, Wang XS, Chen Q. Amperometric glucose biosensor based on multilayer films via layer-by-layer self-assembly of multi-wall carbon nanotubes, gold nanoparticles and glucose oxidase on the Pt electrode. Biosens Bioelectron. 2007;22:2854–60.10.1016/j.bios.2006.11.028 ↗
7. Ahmed S, Dack C, Farace G, Rigby G, Vadgama P. Tissue implanted glucose needle electrodes: early sensor stabilisation and achievement of tissue-blood correlation during the run in period. Anal Chim Acta. 2005;537:153–61.10.1016/j.aca.2005.01.065 ↗
8. Churchouse SJ, Battersby CM, Mullen WH, Vadgama PM. Needle enzyme electrodes for biological studies. Biosens Bioelectron. 1986;2:325–42.10.1016/0265-928X(86)85022-2 ↗
9. Ichimori S, Nishida K, Shimoda S, Sekigami T, Matsuo Y, Ichinose K, Shichiri M, Sakakida M, Araki E. Development of a highly responsive needle-type glucose sensor using polyimide for a wearable artificial endocrine pancreas. J Artif Organs. 2006;9:105–13.10.1007/s10047-005-0326-8 ↗
10. Shen J, Dudik L, Liu CC. An iridium nanoparticles dispersed carbon based thick film electrochemical biosensor and its application for a single use, disposable glucose biosensor. Sensor Actuat B-Chem. 2007;125:106–13.10.1016/j.snb.2007.01.043 ↗
11. Chen Q, Kobayashi Y, Takeshita H, Hoshi T, Anzai J. Avidin-biotin system-based enzyme multilayer membranes for biosensor applications: optimization of loading of choline esterase and choline oxidase in the bienzyme membrane for acetylcholine biosensors. Electroanalysis. 1998;10:94–7.10.1002/(SICI)1521-4109(199802)10:2<94::AID-ELAN94>3.0.CO;2-A ↗
12. Hoshi T, Saiki H, Kuwazawa S, Tsuchiya C, Chen Q, Anzai J. Selective permeation of hydrogen peroxide through polyelectrolyte multilayer films and its use for amperometric biosensors. Anal Chem. 2001;73:5310–5.10.1021/ac010605t ↗
13. Ammam M, Fransaer J. Two-enzyme lactose biosensor based on beta-galactosidase and glucose oxidase deposited by AC-electrophoresis: characteristics and performance for lactose determination in milk. Sensor Actuat B-Chem. 2010;148:583–9.10.1016/j.snb.2010.05.027 ↗
14. Ammam M, Fransaer J. AC-electrophoretic deposition of glucose oxidase. Biosens Bioelectron. 2009;25:191–7.10.1016/j.bios.2009.06.036 ↗
15. Ammam M, Fransaer J. AC-electrophoretic deposition of glucose oxidase (vol 25, pg 191, 2009). Biosens Bioelectron. 2010;25:1856–1856.10.1016/j.bios.2009.11.013 ↗
16. Sorlier P, Denuziere A, Viton C, Domard A. Relation between the degree of acetylation and the electrostatic properties of chitin and chitosan. Biomacromolecules. 2001;2:765–72.10.1021/bm015531+ ↗
17. Wang XY, Gu HF, Yin F, Tu YF. A glucose biosensor based on Prussian blue/chitosan hybrid film. Biosens Bioelectron. 2009;24:1527–30.10.1016/j.bios.2008.09.025 ↗
18. Chen X, Jia JB, Dong SJ. Organically modified sol-gel/chitosan composite based glucose biosensor. Electroanalysis. 2003;15:608–12.10.1002/elan.200390076 ↗
19. Wang G, Xu JJ, Chen HY, Lu ZH. Amperometric hydrogen peroxide biosensor with sol-gel/chitosan network-like film as immobilization matrix. Biosens Bioelectron. 2003;18:335–43.10.1016/S0956-5663(02)00152-5 ↗
20. Cao SS, Mishra R, Pilla S, Tripathi S, Pandey MK, Shah G, Mishra AK, Prabaharan M, Mishra SB, Xin J, Pandey RR, Wu WW, Pandey AC, Tiwari A. Novel chitosan/gold-MPA nanocomposite for sequence-specific oligonucleotide detection. Carbohyd Polym. 2010;82:189–94.10.1016/j.carbpol.2010.04.051 ↗
21. Bharathi S, Nogami M, Ikeda S. Novel electrochemical interfaces with a tunable kinetic barrier by self-assembling organically modified silica gel and gold nanoparticles. Langmuir. 2001;17:1–4.10.1021/la0010572 ↗
22. Deepa PN, Kanungo M, Claycomb G, Sherwood PMA, Collinson MM. Electrochemically deposited sol-gel-derived silicate films as a viable alternative in thin-film design. Anal Chem. 2003;75:5399–405.10.1021/ac026459o ↗
23. Yi HM, Wu LQ, Ghodssi R, Rubloff GW, Payne GF, Bentley WE. A robust technique for assembly of nucleic acid hybridization chips based on electrochemically templated chitosan. Anal Chem. 2004;76:365–72.10.1021/ac034662t ↗
24. Yi HM, Wu LQ, Ghodssi R, Rubloff GW, Payne GF, Bentley WE. Signal-directed sequential assembly of biomolecules on patterned surfaces. Langmuir. 2005;21:2104–7.10.1021/la047529k ↗
25. Xi FN, Liu LJ, Wu Q, Lin XF. One-step construction of biosensor based on chitosan-ionic liquid-horseradish peroxidase biocomposite formed by electrodeposition. Biosens Bioelectron. 2008;24:29–34.10.1016/j.bios.2008.03.023 ↗
26. Zhou QM, Xie QJ, Fu YC, Su ZH, Jia X, Yao SZ. Electrodeposition of carbon nanotubes-chitosan-glucose oxidase biosensing composite films triggered by reduction of p-benzoquinone or H2O2. J Phys Chem B. 2007;111:11276–84.10.1021/jp073884i ↗
27. Li C, Liu Y, Luong JHT. Impedance sensing of DNA binding drugs using gold substrates modified with gold nanoparticles. Anal Chem. 2005;77:478–85.10.1021/ac048672l ↗
28. Wang J. Electrochemical glucose biosensors. Chem Rev. 2008;108:814–25.10.1021/cr068123a ↗
29. Sun YP, Buck H, Mallouk TE. Combinatorial discovery of alloy electrocatalysts for amperometric glucose sensors. Anal Chem. 2001;73:1599–604.10.1021/ac0015117 ↗
30. Shervedani RK, Mehrjardi AH, Zamiri N. A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor. Bioelectrochemistry. 2006;69:201–8.10.1016/j.bioelechem.2006.01.003 ↗
31. Miao XM, Yuan R, Chai YQ, Shi YT, Yuan YY. Direct electrocatalytic reduction of hydrogen peroxide based on Nafion and copper oxide nanoparticles modified Pt electrode. J Electroanal Chem. 2008;612:157–63.10.1016/j.jelechem.2007.09.026 ↗
32. Song MJ, Hwang SW, Whang D. Non-enzymatic electrochemical CuO nanoflowers sensor for hydrogen peroxide detection. Talanta. 2010;80:1648–52.10.1016/j.talanta.2009.09.061 ↗
33. Laviron E, Roullier L. Electrochemical reactions with adsorption of the reactants and electrosorption. Simple analytical solutions for a Henry isotherm. J Electroanal Chem. 1998;443:195–207.10.1016/S0022-0728(97)00502-0 ↗
34. Laviron E. General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems. J Electroanal Chem. 1979;101:19–28.10.1016/S0022-0728(79)80075-3 ↗