In vitro biocompatibility of degradable biopolymers in cell line cultures from various ocular tissues: extraction studies
Source abstract
Abstract
In vitro biocompatibility of 50:50 PDLGA, 85:15 PDLGA, and Inion GTR(TM) membrane was evaluated in cell line cultures from various ocular tissues, in human corneal epithelial cells (HCE), rabbit stromal fibroblasts (SIRC), bovine corneal endothelial cells (BCE), human conjunctival epithelial cells (IOBA-NHC), and human retinal pigment epithelial cells (ARPE-19). To study the toxicity of degradation products, the biomaterials were extracted in phosphate buffered saline at 70 degrees C for 24 h. The cell cultures were exposed to biomaterial extract diluted in medium (1:1-1:8) and the biocompatibility was evaluated by the WST-1 cytotoxicity/cell proliferation test. In all experiments without pH neutralization, cell viability increased with decreasing biomaterial extract volume. The highest extraction ratio 1:1 of PDLGA 50:50 decreased viability from 5-20%, from the control level, depending on the cell type. The corresponding cell viability values for PDLGA 85:15 and Inion GTR membrane ranged from 47-87% and 66-92%, respectively. When the pH of biomaterial extract was neutralized, Inion GTR membrane and PDLGA 85:15 had no effect on viability. BCE, HCE, and IOBA-NHC appeared to the most sensitive cell types, while SIRC and ARPE-19 were more resistant. The results of our in vitro studies suggest that the polymers tested are satisfactorily biocompatible.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Corneal Surgery and Treatments · Ocular Disorders and Treatments · Bone Tissue Engineering Materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. T. YASUKAWA, Y. OGURA, H. KIMURA, E. SAKURAI and Y. TABATA, Expert Opin. Drug Deliv. 3 (2006) 26110.1517/17425247.3.2.261 ↗
2. C. ANDRIEU-SOLER, A. AUBERT-POUESSEL, M. DOAT, S. PICAUD, M. HALHAL, M. SIMONUTTI, M. C. VENIER-JULIENNE, J. P. BENOIT and F. BEHAR-COHEN, Mol. Vis. 11 (2005) 1002
3. R. A. BEJJANI, D. BENEZRA, H. COHEN, J. RIEGER, C. ANDRIEU, J. C. JEANNY, G. GOLLOMB and F. F. BEHAR-COHEN, Mol. Vis. 11 (2005) 124
4. L. C. LU, M. J. YASZEMSKI and A. G. MIKOS, Biomaterials 22 (2001) 334510.1016/S0142-9612(01)00172-7 ↗
5. L. P. ANG, Z. Y. CHENG, R. W. BEUERMAN, S. H. TEOH, X. ZHU and D. T. TAN, Invest. Ophthalmol. Vis. Sci. 47 (2006) 10510.1167/iovs.05-0512 ↗
6. INTERNATIONAL ORGANIZATION FOR STANDARDIZATION, in “Biological Evaluation Of Medical Devices – Part 5: Tests for In Vitro Cytotoxicity (ISO 10993-5:1999)” (International Organization for Standardization, Geneva, 1999). p. 3
7. INTERNATIONAL ORGANIZATION FOR STANDARDIZATION, in “Biological Evaluation Of Medical Devices – Part 12: Sample Preparation And Reference Materials (ISO 10993-12:1996)” (International Organization for Standardization, Geneva, 1996). p. 5
8. K. ARAKI-SASAKI, Y. OHASHI, T. SASABE, K. HAYASHI, H. WATANABE, Y. TANO and H. HANDA, Invest. Ophthalmol. Vis. Sci. 36 (1995) 614
9. J. LEERHOY, Science 149 (1965) 63310.1126/science.149.3684.633 ↗
10. D. GOSPODAROWICZ, A. L. MESCHER and C. R. BIRDWELL, Exp.Eye Res. 25 (1977) 7510.1016/0014-4835(77)90248-2 ↗
11. Y. DIEBOLD, M. CALONGE, A. E. DE SALAMANCA, S. CALLEJO, R. M. CORRALES, V. SAEZ, K. F. SIEMASKO and M. E. STERN, Invest. Ophthalmol. Vis. Sci. 44 (2003) 426310.1167/iovs.03-0560 ↗
12. K. C. DUNN, A. E. AOTAKIKEEN, F. R. PUTKEY and L. M. HJELMELAND, Exp. Eye Res. 62 (1996) 15510.1006/exer.1996.0020 ↗
13. K. A. ATHANASIOU, G. G. NIEDERAUER and C. M. AGRAWAL, Biomaterials 17 (1996) 9310.1016/0142-9612(96)85754-1 ↗
14. T. YASUKAWA, H. KIMURA, Y. TABATA and Y. OGURA, Adv. Drug Deliv. Rev. 52 (2001) 2510.1016/S0169-409X(01)00192-2 ↗
15. J. CAI, K. J. ZHU and S. L. YANG, Polymer 39 (1998) 440910.1016/S0032-3861(97)10346-9 ↗
16. K. J. ZHU, J. X. ZHANG, C. WANG, H. YASUDA, A. ICHIMARU and K. YAMAMOTO, J. Microencapsul. 20 (2003) 73110.3109/02652040309178084 ↗
17. M. S. TAYLOR, A. U. DANIELS, K. P. ANDRIANO and J. HELLER, J. Appl. Biomater. 5 (1994) 15110.1002/jab.770050208 ↗
18. J. B. ULREICH and M. CHAVAPILIN, in “In Vitro Toxicity Testing: A Quantitative Microassay”, Edited by: S. A. Brown (ASTM, Philadelphia, 1983), p. 10210.1520/STP30160S ↗
19. R. ZANGE, Y. LI and T. KISSEL, J. Control. Release 56 (1998) 24910.1016/S0168-3659(98)00093-5 ↗
20. K. R. KIDD, D. Dal PONTE, A. L. STONE, J. B. HOYING, R. B. NAGLE and S. K. WILLIAMS, Tissue Eng. 11 (2005) 137910.1089/ten.2005.11.1379 ↗
21. E. BINZEN, A. LENDLEIN, S. KELCH, D. RICKERT and R. P. FRANKE, Clin. Hemorheol. Microcirc. 30 (2004) 283