Mechanical characterisation of a bone defect model filled with ceramic cements
Source abstract
Abstract
Ceramic bone substitute materials are often used to fill defects in comminuted articular fractures. In an in vivo study [1], calcium phosphate cements have been injected into highly loaded slot defects in the proximal tibial metaphysis. During healing, cracks were formed mostly in the proximal anterior aspect of the implanted cement and wedge-like gaps formed between the tibial plateau and the cement. Mechanical ex vivo tests were done to investigate the mechanical competence of the bone cement in such a defect situation. Entirely filled defects were loaded with up to 4.5 kN until they failed. Cyclic loading of the proximal tibiae caused micro fragmentation of the cement after 1000 cycles at 1.5-2.0 kN load. This aspect was comparable to cement fragmentation observed in vivo. Large defects in highly loaded areas should therefore additionally be stabilised with metallic implants. The ceramic cement can only be used as a filler material, which can be replaced by new bone upon resorption.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials · Bone fractures and treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (16)
Show source-provided references
1. A. GISEP, R. WIELING, M. BOHNER, S. MATTER, E. SCHNEIDER and B. RAHN, J Biomed. Mazer. Res. 66A (2003) 532.
2. P. D. BURSTE1N, S.R. COHEN, R. HUDGINS, W. BOYDSTON and C. SIMMS, Plast. Reconstr. Surg 104(1999) 1270.10.1097/00006534-199910000-00005 ↗
3. K. F. DICKSON, I. FRIEDMAN, I. G. BUCHHOLZ and F. D. FLANDRY, J. Trauma 53(2002) 1103.10.1097/00005373-200212000-00012 ↗
4. P. LOBENH0FFER, T. GERICH F. WITTE and H. TSCHERNE, J Orthop. Trauma 16(2002) 143.10.1097/00005131-200203000-00001 ↗
5. T. A. SCHILDHAUER, T. W. BAUER, C. JOSTEN and G. MUHR, ibid. 14(2000) 309.10.1097/00005131-200006000-00001 ↗
6. K. I. BOZIC, P. A. OLAZER, D. ZURAKOWSKI, B. I. SIMON, S. I. LIPSON and W. C. HAYES, Spine 24(1999) 2127.10.1097/00007632-199910150-00012 ↗
7. B. R. CONSTANTZ, I. C. ISON, M. T. FULMER, R. D. POSER, S. T. SM1TH, M. VANWAGONER, I. ROSS, S. A. GOLDSTEIN, J. B. JUPITER and D. I. ROSENTHAL, Science 267(1995) 1796.10.1126/science.7892603 ↗
8. K. A. HING, S. M. BEST, K. E. TANNER, P. A. REVELL and W. BONFIELD, P I. Mech Eng. H. 212(1998) 437.10.1243/0954411981534204 ↗
9. P. D. COSTANTINO, C. D. FRIEDMAN, K. JONES, L. C. CHOW and G. A. SISSON, Plast. Reconstr. Surg 90(1992) 174.10.1097/00006534-199290020-00003 ↗
10. E. P. FRANKENBURG, S. A. GOLDSTEIN, T. W. BAUER, S. A. HARRIS and R. D. POSER, J. Bone. Joint Surg Am. 80 (1998) 1112.10.2106/00004623-199808000-00004 ↗
11. S.-W. HA and E. WINTERMANTEL, in "Biokompatible Werkstoffe und Bauweisen" (Springer, Berh, 1996) p. 315.10.1007/978-3-662-06077-3_20 ↗
12. J. LEMAITRE, A. A. MIRTCHI and A. MORTIER, Silic.Ind. 9 (1987) 141.
13. J. LEMAITRE, E. MUNTING and A. A. MIRTCHI, Rev. Stomatol. Chir. Maxillofac. 93(1992) 163.
14. K. OHURA, M. BOHNER, P. HARDOUIN, I. LEMAITRE, G. PASQUIER and B. FLAUTRE, J.Biomed. Mater. Res. 30(1996) 193.10.1002/(SICI)1097-4636(199602)30:2<193::AID-JBM9>3.0.CO;2-M ↗
15. G. N. DUDA, K. ECKERT-HUBNER, R. SOKIRANSKI, A. KREUTNER, R. MILLER and L. CLAES, J.Biomech. 31(1998) 201.10.1016/S0021-9290(97)00127-9 ↗
16. B. SURBER, A. GISEP and B. RAHN, Diploma Thesis, ETH Zürich (2000) 26.