Tribological and mechanical performance evaluation of metal prosthesis components manufactured via metal injection molding
Source abstract
Abstract
The increasing number of total joint replacements, in particular for the knee joint, has a growing impact on the healthcare system costs. New cost-saving manufacturing technologies are being explored nowadays. Metal injection molding (MIM) has already demonstrated its suitability for the production of CoCrMo alloy tibial trays, with a significant reduction in production costs, by holding both corrosion resistance and biocompatibility. In this work, mechanical and tribological properties were evaluated on tibial trays obtained via MIM and conventional investment casting. Surface hardness and wear properties were evaluated through Vickers hardness, scratch and pin on disk tests. The MIM and cast finished tibial trays were then subjected to a fatigue test campaign in order to obtain their fatigue load limit at 5 millions cycles following ISO 14879-1 directions. CoCrMo cast alloy exhibited 514 HV hardness compared to 335 HV of MIM alloy, furthermore it developed narrower scratches with a higher tendency towards microploughing than microcutting, in comparison to MIM CoCrMo. The observed fatigue limits were (1,766 ± 52) N for cast tibial trays and (1,625 ± 44) N for MIM ones. Fracture morphologies pointed out to a more brittle behavior of MIM microstructure. These aspects were attributed to the absence of a fine toughening and surface hardening carbide dispersion in MIM grains. Nevertheless, MIM tibial trays exhibited a fatigue limit far beyond the 900 N of maximum load prescribed by ISO and ASTM standards for the clinical application of these devices.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Orthopaedic implants and arthroplasty · Advanced materials and composites · Metal and Thin Film Mechanics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (32)
Show source-provided references
1. Dixon T, Shaw M, Ebrahim S, Dieppe P. Trends in hip and knee joint replacement: socioeconomic inequalities and projections of need. Ann Rheum Dis. 2004;63(7):825–30.10.1136/ard.2003.012724 ↗
2. Kurtz S, Ong K, Lau E, Mowat F, Halpern M. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030. J Bone Joint Surg. 2007;89(4):780–5.10.2106/JBJS.F.00222 ↗
3. Sonntag R, Reinders J, Kretzer JP. What’s next? Alternative materials for articulation in total joint replacement. Acta Biomater. 2012;8(7):2434–41.10.1016/j.actbio.2012.03.029 ↗
4. Barber TC, Healy WL. The hospital cost of total hip arthroplasty. J Bone Joint Surg Am. 1993;75(3):321–5.10.2106/00004623-199303000-00002 ↗
5. Berry G, Bolton JD, Brown JB, McQuaide S (1999) Production and properties of wrought high carbon Co–Cr–Mo alloys. In Cobalt-Base Alloys for Biomedical Applications; Norfolk, VA:3-4 Nov 1998, pp. 11–31.10.1520/STP14260S ↗
6. Dearnley PA. A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements. P I Mech Eng H. 1999;213(2):107–35.10.1243/0954411991534843 ↗
7. Nasab MB, Hassan MR. Metallic biomaterials of knee and hip: a review. Trends Biomater Artificial Organs. 2010;24(1):69–82.
8. Tandon R. Net-shaping of Co-Cr-Mo(F-75) via metal injection molding. ASTM Spec Tech Publ. 1999;1365:3–10.
9. Muterlle PV, Zendron M, Zanella C, Perina M, Bardini R, Molinari A. Effect of Microstructure on the properties of a biomedical Co-Cr-Mo Alloy Produced by MIM. Proceedings of the 2009 International Conference on Powder Metallurgy & Particulate Materials, June 28–July 1, Las Vegas, Nevada 2009.
10. Muterlle PV, Lonardelli I, Perina M, Zendron M, Bardini R, Molinari A. Solution annealing and aging of a MIM CoCrMo alloy. Int J Powder Metall. 2010;46(4):43–51.
11. Muterlle PV, Zendron M, Perina M, Bardini R, Molinari A. Microstructure and tensile properties of metal injection molding Co–29Cr–6Mo–0.23C alloy. J Mater Sci. 2010;45:1091–9.10.1007/s10853-009-4051-1 ↗
12. Melli V, Rondelli G, Sandrini E, Altomare L, Bolelli G, Bonferroni B, Lusvarghi L, De Nardo L. Metal injection molding as enabling technology for the production of metal prosthesis components: electrochemical and in vitro characterization. J Biomed Mater Res B. 2013;101(7):1294–301.10.1002/jbm.b.32942 ↗
13. Ahir SP, Blunn GW, Haider J, Walker PS. Evaluation of a testing method for the fatigue performance of total knee tibial trays. J Biomech. 1999;32:1049–57.10.1016/S0021-9290(99)00094-9 ↗
14. Ahir SP, Blunn G, Harison M, Haider H, Walker PS. Pre-clinical testing of tibial tray designs for their fatigue performance. Combined Orthopaedic Researc Societies Meeting 2001.
15. Villa T, Migliavacca F, Gastaldi D, Colombo M, Pietrabissa R. Contact stresses and fatigue life in a knee prosthesis: comparison between in vitro measurements and computational simulations. J Biomech. 2004;37:45–53.10.1016/S0021-9290(03)00255-0 ↗
16. Yu T-C, Huang C-H, Hsieh C-H, Liau J–J, Huang C-H, Cheng C-K. Fatigue resistance analysis of tibial baseplate in total knee prosthesis: an in vitro biomechanical study. Clin Biomech. 2006;21:147–51.10.1016/j.clinbiomech.2005.08.009 ↗
17. Oliver WC, Pharr GM. An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments. J Mater Res. 1992;7(6):1564–83.10.1557/JMR.1992.1564 ↗
18. Kokubo T, Takadama H. How useful is SBF in predicting in vivo bone bioactivity? Biomaterials. 2006;27(15):2907–15.10.1016/j.biomaterials.2006.01.017 ↗
19. Dixon WJ, Massey FJ. Introduction to statistical analysis. 4 (International student ed) ed. Auckland: McGraw Hill; 1983.
20. Ashby M, Abulawi J, et al. Temperature maps for frictional heating in dry sliding. Tribol T. 1991;34(4):577–87.10.1080/10402009108982074 ↗
21. Brunski JB. Metals. In: Ratner BD, Hoffman AS, Schoen FJ, Lemons JE, editors. Biomaterials Science: An Introduction to Materials in Medicine. London: Elsevier Academic Press; 1996. p. 37–50.
22. Teoh SH. Introduction to biomaterials engineering and processing: an overview. In: Teoh SH, editor. Biomaterials engineering and processing Series Vol 1: engineering materials for biomedical applications. Singapore: World Scientific Publishing; 2004. p. 1–16.
23. Stachwiak GW, Batchelor AW. Engineering tribology. 3rd ed. Burlington: Elsevier; 2005. p. 507–8.
24. Kato K, Adachi K. Wear mechanisms. Modern tribology handbook. 2001;1:273–300.
25. Bolelli G, Cannillo V, et al. Microstructural and tribological comparison of HVOF-sprayed and post-treated M-Mo–Cr–Si (M = Co, Ni) alloy coatings. Wear. 2007;263(7–12):1397–416.10.1016/j.wear.2006.12.002 ↗
26. Bolelli G, Bonferroni B, et al. Micromechanical properties and sliding wear behaviour of HVOF-sprayed Fe-based alloy coatings. Wear. 2012;276–277:29–47.10.1016/j.wear.2011.12.001 ↗
27. Pilliar R. Metallic Biomaterials. In: Narayan R, editor. Biomedical materials. New York: Springer; 2009. p. 41–81.10.1007/978-0-387-84872-3_2 ↗
28. Sharkey PF, Lichstein PM, et al. Why are total knee arthroplasties failing today: has anything changed after 10 years? J Arthroplasty. 2014. doi: 10.1016/j.arth.2013.07.024 .10.1016/j.arth.2013.07.024 ↗
29. Hug KT, Henderson RA, et al. Polished cobalt-chrome vs titanium tibial trays in total knee replacement (a comparison using the PFC Sigma system). Duke Orthop J. 2011;2(1):5–11.10.5005/jp-journals-10017-1011 ↗
30. Paul JP. Strenght requirements for internal and external prosthesis. J Biomech. 1999;32:381–93.10.1016/S0021-9290(98)00190-0 ↗
31. Kutzner I, Heinlein B, et al. Loading of the knee joint during activities of daily living measured in vivo in five subjects. J Biomech. 2010;43:2164–73.10.1016/j.jbiomech.2010.03.046 ↗
32. Teoh SH. Fatigue of biomaterials: a review. Int J Fatigue. 2000;22:825–37.10.1016/S0142-1123(00)00052-9 ↗