Abstract

Accurate image acquisition techniques and analysis protocols for a reliable characterization of tissue engineering scaffolds are yet to be well defined. To this aim, the most promising imaging technique seems to be the X-ray computed microtomography (μ-CT). However critical issues of the analysis process deal with the representativeness of the selected Volume of Interest (VOI) and, most significantly, its segmentation. This article presents an image analysis protocol that computes a set of quantitative descriptors suitable for characterizing the morphology and the micro-architecture of alginate/hydroxyapatite bone tissue engineering scaffolds. Considering different VOIs extracted from different μ-CT datasets, an automated segmentation technique is suggested and compared against a manual segmentation. Variable sizes of VOIs are also considered in order to assess their representativeness. The resulting image analysis protocol is reproducible, parameter-free and it automatically provides accurate quantitative information in addition to the simple qualitative observation of the acquired images.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: 3D Printing in Biomedical Research · Bone Tissue Engineering Materials · Anatomy and Medical Technology

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (46)

Show source-provided references
1. Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC. The optimum pore size for the fixation of porous surfaced metal implants by the ingrowth of bone. Clin Orthop Relat Res. 1980;150:263–70.10.1097/00003086-198007000-00045 ↗
2. Brun F, Dreossi D. Efficient curve-skeleton computation for the analysis of biomedical 3D images. Biomed Sci Instrum. 2010;46:475–80.
3. Brun F, Mancini L, Kasae P, Favretto S, Dreossi D, Tromba G. Pore3D: a software library for quantitative analysis of porous media. Nucl Instrum Methods Phys Res A. 2010;615:326–32.10.1016/j.nima.2010.02.063 ↗
4. Cartmell S, Huynh K, Lin A, Nagaraja S, Guldberg R. Quantitative microcomputed tomography analysis of mineralization within threedimensional scaffolds in vitro. J Biomed Mater Res A. 2010;69:97–104.
5. Darling A, Sun W. 3D microtomographic characterization of precision extruded poly-ε-caprolactone tissue scaffolds. J Biomed Mater Res A. 2004;70:311–7.10.1002/jbm.b.30050 ↗
6. Elmoutaouakkil A, Fuchs G, Bergounhon P, Peres R, Peyrin F. Three-dimensional quantitative analysis of polymer foams from synchrotron radiation X-ray microtomography. J Phys D. 2003;2003:37–43.10.1088/0022-3727/36/10A/308 ↗
7. Filmon R, Gaborit RN, Grizon F, Galloyer M, Cincu C, Basle MF, Chappard D. Non-connected versus interconnected macroporosity in poly(2-hydroxyethyl methacrylate) polymers. An X-ray microtomographic and histomorphometric study. J Biomater Sci Polym Ed. 2002;13:1105–17.10.1163/156856202320813828 ↗
8. Hildebrand T, Rüegsegger P. A new method for the model-independent assessment of thickness in three-dimensional images. J Microsc. 1997;185:67–75.10.1046/j.1365-2818.1997.1340694.x ↗
9. Hilldore A, Wojtowicz A, Johnson AW. Micro-CT based quantification of non-mineralized tissue on cultured hydroxyapatite scaffolds. J Biomed Mater Res A. 2006;82:1012–21.
10. Hilldore A, Morgan AW, Woodard JR, Wagoner Johnson AJ. The curve integration method is comparable to manual segmentation for the analysis of bone/scaffold composites using micro-CT. J Biomed Mater Res B. 2009;88:271–9.10.1002/jbm.b.31178 ↗
11. Ho ST, Hutmacher DW. A comparison of micro CT with other techniques used in the characterization of scaffolds. Biomaterials. 2006;27:1362–76.10.1016/j.biomaterials.2005.08.035 ↗
12. Hollister SJ. Porous scaffold design for tissue engineering. Nat Mater. 2005;4:518–24.10.1038/nmat1421 ↗
13. Hulbert SF, Young FA, Mathews RS, Klawitter JJ, Talbert CD, Stelling FH. Potential of ceramic materials as permanently implantable skeletal prostheses. J Biomed Mater Res. 1970;4:433–56.10.1002/jbm.820040309 ↗
14. Itoh M, Shimazu A, Hirata I, Yoshida Y, Shintani H, Okazaki M. Characterization of CO3Ap-collagen sponges using X-ray high-resolution microtomography. Biomaterials. 2004;25:2577–83.10.1016/j.biomaterials.2003.09.071 ↗
15. Jones AC, Milthorpe B, Averdunk H, Limaye A, Senden TJ, Sakellariou A, Sheppard AP, Sok RM, Knackstedt MA, Brandwood A, Rohner D, Hutmacher DW. Analysis of 3D bone ingrowth into polymer scaffolds via micro-computed tomography imaging. Biomaterials. 2004;25:4947–54.10.1016/j.biomaterials.2004.01.047 ↗
16. Kapur JN, Sahoo PK, Wong AKC. A new method for gray-level picture thresholding using the entropy of the histogram. Graph Models Image Process. 1985;29:273–85.10.1016/0734-189X(85)90125-2 ↗
17. Karageorgiou V, Kaplan D. Porosity of 3D biomaterial scaffolds and osteogenesis. Biomaterials. 2005;26:5474–91.10.1016/j.biomaterials.2005.02.002 ↗
18. Karande TS, Agrawal CM. Functions and requirements of synthetic scaffolds in tissue engineering. In: Laurencin C, Nair L, editors. Nanotechnology and tissue engineering: the scaffold. Broken Sound Parkway, NW: CRC Press; 2008. p. 53–86.10.1201/9781420051834.ch3 ↗
19. Ketcham RA, Ryan TM. Quantification and visualization of anisotropy in trabecular bon. J Microsc. 2004;213:158–71.10.1111/j.1365-2818.2004.01277.x ↗
20. Kittler J, Illingworth J. Minimum error thresholding. Pattern Recogn. 1986;19:41–7.10.1016/0031-3203(86)90030-0 ↗
21. Lin ASP, Barrows TH, Cartmell S, Guldberg R. Microarchitectural and mechanical characterization of oriented porous polymer scaffolds. Biomaterials. 2003;24:481–9.10.1016/S0142-9612(02)00361-7 ↗
22. Lindquist WB. Quantitative analysis of three dimensional X-ray tomographic images. Proc SPIE. 2002;4503:103–15.10.1117/12.452833 ↗
23. Lindquist WB, Lee SM. Medial axis analysis of void structure in three-dimensional tomographic images of porous media. J Geophys Res. 1996;101:8297–310.10.1029/95JB03039 ↗
24. Lindquist B, Venkatarangan A. Investigating 3D geometry of porous media from high resolution images. Phys Chem Earth A. 1999;25:593–9.10.1016/S1464-1895(99)00085-X ↗
25. Malafaya PB, Santos TC, van Griensven M, Reis RL. Morphology, mechanical characterization and in vivo neo-vascularization of chitosan particle aggregated scaffolds architectures. Biomaterials. 2008;29:3914–26.10.1016/j.biomaterials.2008.06.023 ↗
26. Martin I, Mastrogiacomo M, De Leo G, Muraglia A, Beltrame F, Cancedda R, Quarto R. Fluorescence microscopy imaging of bone for automated histomorphometry. Tissue Eng. 2002;8:847–52.10.1089/10763270260424204 ↗
27. Mastrogiacomo M, Komlev V, Hausard M, Peyrin F, Turquier F, Casari S, Cedola A, Rustichelli F, Cancedda R. Synchrotron radiation microtomography of bone engineered from bone marrow stromal cells. Tissue Eng. 2004;10:1767–74.10.1089/ten.2004.10.1767 ↗
28. Mastrogiacomo M, Scaglione S, Martinetti R, Dolcini L, Beltrame F, Cancedda R. Role of scaffold internal structure on in vivo bone formation in macro-porous calcium phospate bioceramics. Biomaterials. 2006;27:3230–7.10.1016/j.biomaterials.2006.01.031 ↗
29. Moore MJ, Jabbari E, Ritman EL, Lu L, Currier BL, Windebank AJ, Yaszemski MJ. Quantitative analysis of interconnectivity of porous biodegradable scaffolds with micro-computed tomography. J Biomed Mater Res A. 2004;71:258–67.10.1002/jbm.a.30138 ↗
30. Murugan R, Ramakrishna S. Bioresorbable composite bone paste using polysaccharide based nano hydroxyapatite. Biomaterials. 2004;25:3829–35.10.1016/j.biomaterials.2003.10.016 ↗
31. Odgaard A, Gundersen HJ. Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions. Bone. 1993;14:173–82.10.1016/8756-3282(93)90245-6 ↗
32. Oh W, Lindquist B. Image thresholding by indicator kriging. IEEE Trans Pattern Anal Mach Intell. 1999;21:590–602.10.1109/34.777370 ↗
33. Ohser J, Schladitz K. 3D images of materials structures: processing and analysis. Weinheim: Wiley-VCH; 2009.10.1002/9783527628308 ↗
34. Otsu N. A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern. 1979;9:62–6.10.1109/TSMC.1979.4310076 ↗
35. Otsuki B, Takemoto M, Fujibayashi S, Neo M, Kokubo T, Nakamura T. Pore throat size and connectivity determine bone and tissue ingrowth into porous implants: three-dimensional micro-CT based structural analyses of porous bioactive titanium implants. Biomaterials. 2006;27:5892–900.10.1016/j.biomaterials.2006.08.013 ↗
36. Peyrin F, Mastrogiacomo M, Cancedda R, Martinetti R. SEM and 3D synchrotron radiation micro-tomography in the study of bioceramic scaffolds for tissue-engineering applications. Biotechnol Bioeng. 2007;97:638–48.10.1002/bit.21249 ↗
37. Pun T. Entropic thresholding: a new approach. Comp Graph Image Process. 1981;16:210–39.10.1016/0146-664X(81)90038-1 ↗
38. Rajagopalan S, Lu L, Yaszemski MJ, Robb RA. Optimal segmentation of microcomputed tomographic images of porous tissue-engineering scaffolds. J Biomed Mater Res A. 2005;75:877–87.10.1002/jbm.a.30498 ↗
39. Ridler TW, Calvard S. Picture thresholding using an iterative selection method. IEEE Trans Syst Man Cybern. 1978;8:630–2.10.1109/TSMC.1978.4310039 ↗
40. Rosenfeld A, Kak AC. Digital picture processing. New York: Academic Press, Inc; 1982.
41. Sezgin M, Sankur B. Survey over image thresholding techniques and quantitative performance evaluation. J Electron Imag. 2004;13:146–65.10.1117/1.1631315 ↗
42. Tsai WH. Moment-preserving thresholding: a new approach. Graph Models Image Process. 1985;19:377–93.10.1016/0734-189X(85)90133-1 ↗
43. Turco G, Marsich E, Bellomo F, Semeraro S, Donati I, Brun F, Grandolfo M, Accardo A, Paoletti S. Alginate/hydroxyapatite biocomposite for bone ingrowth: a trabecular structure with high and isotropic connectivity. Biomacromolecules. 2009;10:1575–83.10.1021/bm900154b ↗
44. Whitehouse WJ. The quantitative morphology of anisotropic trabecular bone. J Microsc. 1974;101:153–68.10.1111/j.1365-2818.1974.tb03878.x ↗
45. Yasnoff WA, Mui JK, Bacus JW. Error measures for scene segmentation. Pattern Recogn. 1977;9:217–31.10.1016/0031-3203(77)90006-1 ↗
46. Zhang YJ. A survey on evaluation methods for image segmentation. Pattern Recogn. 1996;29:1335–46.10.1016/0031-3203(95)00169-7 ↗