The present study assessed in vivo new bone formation around titanium alloy implants chemically grafted with macromolecules bearing ionic sulfonate and/or carboxylate groups. Unmodified and grafted Ti-6Al-4V exhibiting either 100% carboxylate, or 100% sulfonate, or both carboxylate and sulfonate groups in the percent of 50/50 and 80/20 were bilaterally implanted into rabbit femoral condyle. Neither toxicity nor inflammation were observed for all implants tested. After 4 weeks, peri-implant new bone formation varied as a function of the chemical composition of the titanium surfaces. The percent bone-implant contact (BIC) was the lowest (13.4 +/- 6.3%) for the implants modified with grafted carboxylate only. The value of BIC on the implants with 20% sulfonate (24.6 +/- 5.2%) was significantly (P < 0.05) lower than that observed on 100% sulfonate (38.2 +/- 13.2%) surfaces. After both 4 and 12 weeks post-implantation, the BIC value for implants with more than 50% sulfonate was similar to that obtained with the unmodified Ti-6Al-4V. The grafted titanium alloy exhibiting either 100% sulfonate or carboxylate and sulfonate (50% each) groups promoted bone formation. Such materials are of clinical interest because, they do not promote bacteria adhesion but, they support new bone formation, a condition which can lead to osseointegration of bone implants while preventing peri-implant infections.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (28)

Show source-provided references
1. Esposito M, Hirsch JM, Lekholm U, Thomsen P. Biological factors contributing tofailures of osseointegrated oral implants. (II). Etiopathogenesis. Eur J Oral Sci. 1998;106:721–64.10.1046/j.0909-8836..t01-6-.x ↗
2. Roos-Jansaker AM, Renvert S, Egelberg J. Treatment of peri-implant infections: a literature review. J Clin Periodontol. 2003;30:467–85.10.1034/j.1600-051X.2003.00296.x ↗
3. Hetrick EM, Schoenfisch MH. Reducing implant-related infections: active release strategies. Chem Soc Rev. 2006;35:780–9.10.1039/b515219b ↗
4. Norowski PA Jr, Bumgardner JD. Biomaterial and antibiotic strategies for peri-implantitis: a review. J Biomed Mater Res B Appl Biomater. 2009;88:530–43.10.1002/jbm.b.31152 ↗
5. Yoshinari M, Oda Y, Kato T, Okuda K, Hirayama A. Influence of surface modifications to titanium on oral bacterial adhesion in vitro. J Biomed Mater Res. 2000;52:388–94.10.1002/1097-4636(200011)52:2<388::AID-JBM20>3.0.CO;2-E ↗
6. Cen L, Neoh KG, Kang ET. Antibacterial activity of cloth functionalized with N-alkylated poly(4-vinylpyridine). J Biomed Mater Res A. 2004;71:70–80.10.1002/jbm.a.30125 ↗
7. Tiller JC, Liao CJ, Lewis K, Klibanov AM. Designing surfaces that kill bacteria on contact. Proc Natl Acad Sci USA. 2001;98:5981–5.10.1073/pnas.111143098 ↗
8. Chua PH, Neoh KG, Kang ET, Wang W. Surface functionalization of titanium with hyaluronic acid/chitosan polyelectrolyte multilayers and RGD for promoting osteoblast functions and inhibiting bacterial adhesion. Biomaterials. 2008;29:1412–21.10.1016/j.biomaterials.2007.12.019 ↗
9. Berlot S, Aissaoui Z, Pavon-Djavid G, Belleney J, Jozefowicz M, Helary G, et al. Biomimetic poly(methyl methacrylate)-based terpolymers: modulation of bacterial adhesion effect. Biomacromolecules. 2002;3:63–8.10.1021/bm015580m ↗
10. Anagnostou F, Debet A, Pavon-Djavid G, Goudaby Z, Helary G, Migonney V. Osteoblast functions on functionalized PMMA-based polymers exhibiting Staphylococcus aureus adhesion inhibition. Biomaterials. 2006;27:3912–9.10.1016/j.biomaterials.2006.03.004 ↗
11. Crémieux A, Pavon-Djavid G, Saleh Mghir A, Hélary G, Migonney V. Bioactive polymers grafted on silicone to prevent Staphylococcus aureus prosthesis adherence: in vitro and in vivo studies. JABBS. 2003;1:178–85.
12. Zhou J, Pavon-Djavid G, Anagnostou F, Migonney V. Inhibition de l’adherence de Porphyromonas gingivalis sur la surface de titane greffe de poly(styrene sulfonate de sodium). ITBM-RBM. 2007;28:42–8.
13. Latz C, Pavon-Djavid G, Helary G, Evans M, Migonney V. Alternative intracellular signaling mechanism involved in the inhibitory biological response of functionalized PMMA-based polymers. Biomacromolecules. 2003;4:766–71.10.1021/bm025764g ↗
14. El Khadali F, Helary G, Pavon-Djavid G, Migonney V. Modulating fibroblast cell proliferation with functionalized poly(methyl methacrylate) based copolymers: chemical composition and monomer distribution effect. Biomacromolecules. 2002;3:51–6.10.1021/bm015563x ↗
15. Mueller WD, Gross U, Fritz T, Voigt C, Fischer P, Berger G, et al. Evaluation of the interface between bone and titanium surfaces being blasted by aluminium oxide or bioceramic particles. Clin Oral Implants Res. 2003;14:349–56.10.1034/j.1600-0501.2003.00791.x ↗
16. Helary G, Noirclere F, Mayingi J, Migonney V. A new approach to graft bioactive polymer on titanium implants: Improvement of MG 63 cell differentiation onto this coating. Acta Biomater. 2009;5:124–33.10.1016/j.actbio.2008.07.037 ↗
17. Mayingi J, Helary G, Noirclere F, Bacroix B, Migonney V. Grafting of bioactive polymers onto titanium surfaces and human osteoblasts response. Conf Proc IEEE Eng Med Biol Soc. 2007;1:5119–22.
18. Puleo DA, Nanci A. Understanding and controlling the bone-implant interface. Biomaterials. 1999;20:2311–21.10.1016/S0142-9612(99)00160-X ↗
19. Sul YT, Johansson C, Byon E, Albrektsson T. The bone response of oxidized bioactive and non-bioactive titanium implants. Biomaterials. 2005;26:6720–30.10.1016/j.biomaterials.2005.04.058 ↗
20. Hanawa T, Kamiura Y, Yamamoto S, Kohgo T, Amemiya A, Ukai H, et al. Early bone formation around calcium-ion-implanted titanium inserted into rat tibia. J Biomed Mater Res. 1997;36:131–6.10.1002/(SICI)1097-4636(199707)36:1<131::AID-JBM16>3.0.CO;2-L ↗
21. De Maeztu MA, Alava JI, Gay-Escoda C. Ion implantation: surface treatment for improving the bone integration of titanium and Ti6Al4V dental implants. Clin Oral Implants Res. 2003;14:57–62.10.1034/j.1600-0501.2003.140108.x ↗
22. Cooper LF, Zhou Y, Takebe J, Guo J, Abron A, Holmen A, et al. Fluoride modification effects on osteoblast behavior and bone formation at TiO2 grit-blasted c.p. titanium endosseous implants. Biomaterials. 2006;27:926–36.10.1016/j.biomaterials.2005.07.009 ↗
23. Bagno A, Di Bello C. Surface treatments and roughness properties of Ti-based biomaterials. J Mater Sci Mater Med. 2004;15:935–49.10.1023/B:JMSM.0000042679.28493.7f ↗
24. Davies JE. Understanding peri-implant endosseous healing. J Dent Educ. 2003;67:932–49.10.1002/j.0022-0337.2003.67.8.tb03681.x ↗
25. Thor A, Rasmusson L, Wennerberg A, Thomsen P, Hirsch JM, Nilsson B, et al. The role of whole blood in thrombin generation in contact with various titanium surfaces. Biomaterials. 2007;28:966–74.10.1016/j.biomaterials.2006.10.020 ↗
26. Rupprecht S, Bloch-Birkholz A, Lethaus B, Rosiwal S, Neukam FW, Schlegel A. The bone-metal interface of defect and press-fit ingrowth of microwave plasma-chemical vapor deposition implants in the rabbit model. Clin Oral Implants Res. 2005;16:98–104.10.1111/j.1600-0501.2004.01079.x ↗
27. Tavares MG, de Oliveira PT, Nanci A, Hawthorne AC, Rosa AL, Xavier SP. Treatment of a commercial, machined surface titanium implant with H2SO4/H2O2 enhances contact osteogenesis. Clin Oral Implants Res. 2007;18:452–8.10.1111/j.1600-0501.2007.01344.x ↗
28. Abrahamsson I, Berglundh T, Linder E, Lang NP, Lindhe J. Early bone formation adjacent to rough and turned endosseous implant surfaces. An experimental study in the dog. Clin Oral Implants Res. 2004;15:381–92.10.1111/j.1600-0501.2004.01082.x ↗