journal article·2022-07Open access

Concepts and clinical aspects of active implants for the treatment of bone fractures

Bergita Ganse, Marcel Orth, Michael Roland, Stefan Diebels, Paul Motzki, Stefan Seelecke, Susanne-Marie Kirsch, Felix Welsch, Annchristin Andres, Kerstin Wickert, Benedikt J Braun, Tim Pohlemann

Acta Biomaterialia· Volume 146

Abstract

Nonunion is a complication of long bone fractures that leads to disability, morbidity and high costs. Early detection is difficult and treatment through external stimulation and revision surgery is often a lengthy process. Therefore, alternative diagnostic and therapeutic options are currently being explored, including the use of external and internal sensors. Apart from monitoring fracture stiffness and displacement directly at the fracture site, it would be desirable if an implant could also vary its stiffness and apply an intervention to promote healing, if needed. This could be achieved either by a predetermined protocol, by remote control, or even by processing data and triggering the intervention itself (self-regulated 'intelligent' or 'smart' implant). So-called active or smart materials like shape memory alloys (SMA) have opened up opportunities to build active implants. For example, implants could stimulate fracture healing by active shortening and lengthening via SMA actuator wires; by emitting pulses, waves, or electromagnetic fields. However, it remains undefined which modes of application, forces, frequencies, force directions, time durations and periods, or other stimuli such implants should ideally deliver for the best result. The present paper reviews the literature on active implants and interventions for nonunion, discusses possible mechanisms of active implants and points out where further research and development are needed to build an active implant that applies the most ideal intervention. STATEMENT OF SIGNIFICANCE: Early detection of delays during fracture healing and timely intervention are difficult due to limitations of the current diagnostic strategies. New diagnostic options are under evaluation, including the use of external and internal sensors. In addition, it would be desirable if an implant could actively facilitate healing ('Intelligent' or 'smart' implant). Implants could stimulate fracture healing via active shortening and lengthening; by emitting pulses, waves, or electromagnetic fields. No such implants exist to date, but new composite materials and alloys have opened up opportunities to build such active implants, and several groups across the globe are currently working on their development. The present paper is the first review on this topic to date.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Bone fractures and treatments · Hip and Femur Fractures · Pelvic and Acetabular Injuries

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (100+)

Show source-provided references
1. Effects of Mechanical Factors on the Fracture Healing Process10.1097/00003086-199810001-00015 ↗
2. The influence of biomechanical stability on bone healing and fracture-related infection: the legacy of Stephan Perren10.1016/j.injury.2020.06.044 ↗
3. A Concert between Biology and Biomechanics: the Influence of the Mechanical Environment on Bone Healing10.3389/fphys.2016.00678 ↗
4. The reliability of plain radiography in experimental fracture healing10.1007/s002560000317 ↗
5. A new method for measurement of bone deformation by echo tracking10.1016/j.medengphy.2005.09.005 ↗
6. A new method for evaluation of fracture healing by echo tracking10.1016/j.ultrasmedbio.2007.11.005 ↗
7. An Ultrasound Wearable System for the Monitoring and Acceleration of Fracture Healing in Long Bones10.1109/TBME.2005.851507 ↗
8. Smart implants in orthopaedic surgery, improving patient outcomes: a review10.2147/IEH.S133518 ↗
9. Biomechanical methods for the assessment of fracture repair10.1016/j.injury.2014.04.006 ↗
10. Telemetric assessment of bone healing with an instrumented internal fixator: a preliminary study10.1302/0301-620X.94B3.27550 ↗
11. Programable Active Fixator System for Systematic In Vivo Investigation of Bone Healing Processes10.3390/s21010017 ↗
12. Monitoring and healing analysis of 100 tibial shaft fractures10.1007/s00423-002-0306-x ↗
13. Clinical feasibility of fracture healing assessment through continuous monitoring of implant load10.1016/j.jbiomech.2020.110188 ↗
14. Dynamic interfragmentary motion in fractures during routine patient activity10.1097/00003086-199703000-00030 ↗
15. The influence of induced micromovement upon the healing of experimental tibial fractures10.1302/0301-620X.67B4.4030869 ↗
16. Low-magnitude high-frequency mechanical signals accelerate and augment endochondral bone repair: preliminary evidence of efficacy10.1002/jor.20824 ↗
17. In vivo measurement of bending stiffness in fracture healing10.1186/1475-925X-2-8 ↗
18. Load transmission through a healing tibial fracture10.1016/j.clinbiomech.2005.08.011 ↗
19. Assessment of fracture healing in orthopaedic trauma
20. Smart implants in fracture care – Only buzzword or real opportunity?
21. High-speed and high-efficiency shape memory alloy actuation
22. Modeling and Design Optimization of a Rotational Soft Robotic System Driven by Double Cone Dielectric Elastomer Actuators Front10.3389/frobt.2019.00150 ↗
23. Shape Memory Alloy Actuators: modelling and Simulation10.1115/1.1584064 ↗
24. L. Zimmer, R. Britz, Y. Goergen, G. Rizzello, T. Pohlemann, M. Orth, B. Ganse, S. Seelecke, P. Motzki, An SMA-based multifunctional implant for improved bone fracture healing, SMASIS2021-67261 doi:10.1115/SMASIS2021-6726110.1115/SMASIS2021-67261 ↗
25. Tibiotalocalcaneal Arthrodesis Utilizing a Titanium Intramedullary Nail With an Internal Pseudoelastic Nitinol Compression Element: a Retrospective Case Series of 33 Patients10.1053/j.jfas.2018.08.046 ↗
26. Smart materials in cardiovascular implants: shape memory alloys and shape memory polymers10.1111/aor.13851 ↗
27. Computational mechanics of Nitinol stent grafts10.1016/j.jbiomech.2008.05.032 ↗
28. Radiographic Results of Nitinol Compression Staples for Hindfoot and Midfoot Arthrodeses10.1177/1071100717737740 ↗
29. Fracture nonunion in long bones: a literature review of risk factors and surgical management10.1016/j.injury.2020.11.029 ↗
30. Prevalence and influencing factors of nonunion in patients with tibial fracture: systematic review and meta-analysis10.1186/s13018-020-01904-2 ↗
31. Clinical and Radiographic Predictors of Nonunion in Open Tibial Shaft Fractures10.3928/01477447-20210416-04 ↗
32. Prevalence of long-bone non-unions10.1016/S0020-1383(07)80003-9 ↗
33. Epidemiology of Fracture Nonunion in 18 Human Bones10.1001/jamasurg.2016.2775 ↗
34. Improvement of clinical fracture healing - What can be learned from mechano-biological research?10.1016/j.jbiomech.2020.110148 ↗
35. Risk factors for long bone fracture non-union: a stratification approach based on the level of the existing scientific evidence10.1016/S0020-1383(15)30049-8 ↗
36. Staged management of high-energy proximal tibia fractures (OTA types 41): the results of a prospective, standardized protocol10.1097/01.bot.0000171881.11205.80 ↗
37. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones: retrospective and prospective analyses10.2106/00004623-197658040-00004 ↗
38. Staged minimally invasive plate osteosynthesis of proximal tibial fractures with acute compartment syndrome10.1016/j.injury.2017.03.010 ↗
39. Base Deficit ≥ 6 within 24h of Injury is a risk factor for fracture nonunion in the polytraumatized patient10.1016/j.injury.2021.05.024 ↗
40. Mechanics and mechanobiology of fracture healing in normal and osteoporotic bone10.1007/s00198-004-1728-9 ↗
41. Fracture healing: the diamond concept10.1016/S0020-1383(08)70003-2 ↗
42. VEGF-loaded mineral-coated microparticles improve bone repair and are associated with increased expression of epo and RUNX-2 in murine non-unions10.1002/jor.24267 ↗
43. Liedert · 2005
44. Diaphyseal long bone nonunions - types, aetiology, economics, and treatment recommendations10.1007/s00264-017-3734-5 ↗
45. Conservative treatment options for non-unions10.1007/s00113-020-00851-1 ↗
46. Low-intensity pulsed ultrasound (LIPUS) for stimulation of bone healing - a narrative review10.1016/j.injury.2021.05.002 ↗
47. Low intensity pulsed ultrasound (LIPUS) use for the management of instrumented, infected, and fragility non-unions: a systematic review and meta-analysis of healing proportions10.1186/s12891-021-04322-5 ↗
48. Use of extracorporeal shock-wave therapy (ESWT) in the treatment of non-unions. A review of the literature10.1007/s00402-001-0365-4 ↗
49. Pulsed electromagnetic fields for the treatment of tibial delayed unions and nonunions. A prospective clinical study and review of the literature10.1186/1749-799X-7-24 ↗
50. Early application of pulsed electromagnetic field in the treatment of postoperative delayed union of long-bone fractures: a prospective randomized controlled study10.1186/1471-2474-14-35 ↗
51. Ultrasound as a stimulus for musculoskeletal disorders10.1016/j.jot.2017.03.004 ↗
52. Complex tibial fracture outcomes following treatment with low-intensity pulsed ultrasound10.1016/j.ultrasmedbio.2003.11.008 ↗
53. Low-intensity pulsed ultrasound (LIPUS) for stimulation of bone healing - a narrative review10.1016/j.injury.2021.05.002 ↗
54. Osteogenic activity of human fracture haematoma-derived progenitor cells is stimulated by low-intensity pulsed ultrasound in vitro10.1302/0301-620X.91B2.20827 ↗
55. Prolonged endochondral bone healing in senescence is shortened by low-intensity pulsed ultrasound in a manner dependent on COX-210.1016/j.ultrasmedbio.2010.04.011 ↗
56. Pulsed low intensity ultrasound enhances mineralisation in preosteoblast cells10.1016/j.ultrasmedbio.2006.12.003 ↗
57. The effects of LIPUS on soft-tissue healing: a review of literature10.1093/bmb/ldn040 ↗
58. Effects of low-intensity pulsed ultrasound on soft tissue micro-circulation in the foot10.1007/s00264-017-3574-3 ↗
59. Extracorporeal shock wave therapy: an update10.1302/2058-5241.5.190067 ↗
60. Biological mechanism of shockwave in bone10.1016/j.ijsu.2015.06.059 ↗
61. Extracorporeal shockwave therapy for avascular necrosis of femoral head10.1016/j.ijsu.2015.06.080 ↗
62. 1998
63. Osteonecrosis of the humeral head after extracorporeal shock-wave lithotripsy10.1302/0301-620X.84B5.0840744 ↗
64. Dose-related effects of shock waves on rabbit tendon Achillis10.1302/0301-620X.80B3.0800546 ↗
65. Pulsed Electromagnetic Fields in Bone Healing: molecular Pathways and Clinical Applications10.3390/ijms22147403 ↗
66. Physical Stimulations for Bone and Cartilage Regeneration10.1007/s40883-018-0064-0 ↗
67. Pulsed electromagnetic fields simultaneously induce osteogenesis and upregulate transcription of bone morphogenetic proteins 2 and 4 in rat osteoblasts in vitro10.1006/bbrc.1998.9243 ↗
68. Pulsed electromagnetic fields (PEMF) attenuate changes in vertebral bone mass, architecture and strength in ovariectomized mice10.1016/j.bone.2017.12.008 ↗
69. Electrical stimulation induces the level of TGF-beta1 mRNA in osteoblastic cells by a mechanism involving calcium/calmodulin pathway10.1006/bbrc.1997.7118 ↗
70. On the relationship between tibia torsional deformation and regional muscle contractions in habitual human exercises in vivo10.1016/j.jbiomech.2014.12.031 ↗
71. Torsion and antero-posterior bending in the in-vivo human tibia loading regimes during walking and running10.1371/journal.pone.0094525 ↗
72. Weight-bearing recommendations after operative fracture treatment-fact or fiction? Gait results with and feasibility of a dynamic, continuous pedobarography insole10.1007/s00264-017-3481-7 ↗
73. Duda · Arch. Surg. · 2003 · 388 · 29810.1007/s00423-003-0386-2 ↗
74. Partial weight bearing of the tibia10.1016/j.injury.2016.06.003 ↗
75. Influence of the fixation stability on the healing time–a numerical study of a patient-specific fracture healing process10.1016/j.clinbiomech.2010.03.003 ↗
76. Effect of controlled axial micromovement on healing of tibial fractures10.1016/S0140-6736(86)92196-3 ↗
77. Lower extremity fractures in patients with spinal cord injury characteristics, outcome and risk factors for non-unions10.1080/10790268.2017.1329915 ↗
78. Effect of loading and fracture motions on diaphyseal tibial fractures10.1002/jor.1100140114 ↗
79. Controlled mechanical stimulation in the treatment of tibial fractures10.1097/00003086-198904000-00006 ↗
80. Tibial external fixation, weight bearing, and fracture movement10.1097/00003086-199308000-00005 ↗
81. Strategies to Improve Bone Healing: innovative Surgical Implants Meet Nano-/Micro-Topography of Bone Scaffolds10.3390/biomedicines9070746 ↗
82. A comparative finite element simulation of locking compression plate materials for tibial fracture treatment10.1080/10255842.2020.1867114 ↗
83. An individualized simulation model based on continuous, independent, ground force measurements after intramedullary stabilization of a tibia fracture
84. Individualized determination of the mechanical fracture environment after tibial exchange nailing-a simulation-based feasibility study10.3389/fsurg.2021.749209 ↗
85. An optimization algorithm for individualized biomechanical analysis and simulation of tibia fractures10.1016/j.jbiomech.2015.01.015 ↗
86. Personalized orthopedic trauma surgery by applied clinial mechanics
87. Numerical simulation of callus healing for optimization of fracture fixation stiffness10.1371/journal.pone.0101370 ↗
88. Assessing hip fracture risk in type-2 diabetic patients using CT-based autonomous finite element methods: a feasibility study10.1302/0301-620X.103B9.BJJ-2020-2147.R1 ↗
89. Patient-specific computed tomography-based finite element analysis: a new tool to assess fracture risk in benign bone lesions of the femur10.1016/j.clinbiomech.2020.105155 ↗
90. Thermomechanis of volumetric growth in uniform bodies10.1016/S0749-6419(99)00081-9 ↗
91. Fung · 2001
92. A constrained mixture model for growth and remodeling of soft tissues10.1142/S0218202502001714 ↗
93. A thermodynamic-consistent model describing growth and remodeling phenomena10.1016/j.commatsci.2003.08.016 ↗
94. Patient-specific finite element analysis of the human femur–a double-blinded biomechanical validation10.1016/j.jbiomech.2011.03.024 ↗
95. Experimental validation of a finite element model of a human cadaveric tibia10.1115/1.2913335 ↗
96. Shear movement at the fracture site delays healing in a diaphyseal fracture model10.1016/S0736-0266(03)00098-6 ↗
97. Shear Does Not Necessarily Inhibit Bone Healing10.1097/01.blo.0000191272.34786.09 ↗
98. The influence of cyclic compression and distraction on the healing of experimental tibial fractures10.1016/j.orthres.2003.11.007 ↗
99. The influence of compression on the healing of experimental tibial fractures10.1016/j.injury.2010.08.018 ↗
100. The effects of external mechanical stimulation on the healing of diaphyseal osteotomies fixed by flexible external fixation10.1016/S0268-0033(98)00097-7 ↗