Nanopore formation on the surface oxide of commercially pure titanium grade 4 using a pulsed anodization method in sulfuric acid
Source abstract
Abstract
Titanium and its alloys form a thin amorphous protective surface oxide when exposed to an oxygen environment. The properties of this oxide layer are thought to be responsible for titanium and its alloys biocompatibility, chemical inertness, and corrosion resistance. Surface oxide crystallinity and pore size are regarded to be two of the more important properties in establishing successful osseointegration. Anodization is an electrochemical method of surface modification used for colorization marking and improved bioactivity on orthopedic and dental titanium implants. Research on titanium anodization using sulphuric acid has been reported in the literature as being primarily conducted in molarity levels 3 M and less using either galvanostatic or potentiostatic methods. A wide range of pore diameters ranging from a few nanometers up to 10 μm have been shown to form in sulfuric acid electrolytes using the potentiostatic and galvanostatic methods. Nano sized pores have been shown to be beneficial for bone cell attachment and proliferation. The purpose of the present research was to investigate oxide crystallinity and pore formation during titanium anodization using a pulsed DC waveform in a series of sulfuric acid electrolytes ranging from 0.5 to 12 M. Anodizing titanium in increasing sulfuric acid molarities showed a trend of increasing transformations of the amorphous natural forming oxide to the crystalline phases of anatase and rutile. The pulsed DC waveform was shown to produce pores with a size range from ≤0.01 to 1 μm(2). The pore size distributions produced may be beneficial for bone cell attachment and proliferation.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (27)
Show source-provided references
1. Textor M, Sittig C, Frauchiger V, Tosatti S, Brunette DM. Properties and biological significance of natural oxide films on titanium and its alloys. Titanium in medicine: material science, surface science, engineering, biological responses, and medical applications. New York: Springer; 2001. p. 171–230.
2. Sul Y-T, Johansson CB, Jeong Y, Albrektsson T. The electrochemical oxide growth behaviour on titanium in acid and alkaline electrolytes. Med Eng Phys. 2001;23(5):329–46.10.1016/S1350-4533(01)00050-9 ↗
3. Diamanti MV, Pedeferri MP. Effect of anodic oxidation parameters on the titanium oxides formation. Corros Sci. 2007;49(2):939–48.10.1016/j.corsci.2006.04.002 ↗
4. Park IS, Woo TG, Jeon WY, Park HH, Lee MH, Bae TS, et al. Surface characteristics of titanium anodized in the four different types of electrolyte. Electrochim Acta. 2007;53(2):863–70.10.1016/j.electacta.2007.07.067 ↗
5. Anodization: a promising nano-modification technique of titanium-based implants for orthopedic applications. In: Jackson MJ, Ahmed, W, editors. Surface engineered surgical tools and medical devices. New York: Springer; 2007.10.1007/978-0-387-27028-9_2 ↗
6. Cassaignon S, Koelsch M, Jolivet J-P. Selective synthesis of brookite, anatase and rutile nanoparticles: thermolysis of TiCl4 in aqueous nitric acid. J Mater Sci. 2007;42(16):6689–95.10.1007/s10853-007-1496-y ↗
7. Yang B, Uchida M, Kim H-M, Zhang X, Kokubo T. Preparation of bioactive titanium metal via anodic oxidation treatment. Biomaterials. 2004;25(6):1003–10.10.1016/S0142-9612(03)00626-4 ↗
8. Cui X, Kim HM, Kawashita M, Wang L, Xiong T, Kokubo T, et al. Preparation of bioactive titania films on titanium metal via anodic oxidation. Dent Mater. 2009;25(1):80–6.10.1016/j.dental.2008.04.012 ↗
9. Gopal J, George RP, Muraleedharan P, Khatak HS. Photocatalytic inhibition of microbial adhesion by anodized titanium. Biofouling. 2004;20(3):167–75.10.1080/08927010400008563 ↗
10. Kuromoto NK, Simao RA, Soares GA. Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages. Mater Charact. 2007;58(2):114–21.10.1016/j.matchar.2006.03.020 ↗
11. Xia Z, Nanjo H, Tetsuka H, Ebina T, Izumisawa M, Fujimura M, et al. Crystallization of the anodic oxide on titanium in sulphuric acids solution at a very low potential. Electrochem Commun. 2007;9(4):850–6.10.1016/j.elecom.2006.11.027 ↗
12. Yu W-Q, Jiang X-Q, Zhang F-Q, Xu L. The effect of anatase TiO2 nanotube layers on MC3T3-E1 preosteoblast adhesion, proliferation, and differentiation. J Biomed Mater Res Part A. 2009;94A(4):1012–22.
13. Jensen M, Fuierer P. Low-temperature preparation of nanocrystalline anatase films through a sol–gel route. J Sol–Gel Sci Technol. 2006;39(3):229–33.10.1007/s10971-006-7837-5 ↗
14. Sul Y-T, Johansson CB, Petronis S, Krozer A, Jeong Y, Wennerberg A, et al. Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: the oxide thickness, micropore configurations, surface roughness, crystal structure and chemical composition. Biomaterials. 2002;23(2):491–501.10.1016/S0142-9612(01)00131-4 ↗
15. Sul Y-T. The significance of the surface properties of oxidized titanium to the bone response: special emphasis on potential biochemical bonding of oxidized titanium implant. Biomaterials. 2003;24(22):3893–907.10.1016/S0142-9612(03)00261-8 ↗
16. Gaul E. Coloring titanium and related metals by electrochemical oxidation. J Chem Educ. 1993;70(3):176–8.10.1021/ed070p176 ↗
17. Li L-H, Kong Y-M, Kim H-W, Kim Y-W, Kim H-E, Heo S-J, et al. Improved biological performance of Ti implants due to surface modification by micro-arc oxidation. Biomaterials. 2004;25(14):2867–75.10.1016/j.biomaterials.2003.09.048 ↗
18. Robinson HJ, Markaki AE, Collier CA, Clyne TW. Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique. J Mech Behav Biomed Mater. 2011;4(8):2103–12.10.1016/j.jmbbm.2011.07.009 ↗
19. Mirelman LK, Curran JA, Clyne TW. The production of anatase-rich photoactive coatings by plasma electrolytic oxidation. Surf Coat Technol. 2012;207:66–71.10.1016/j.surfcoat.2012.05.076 ↗
20. Delplancke JL, Winand R. Galvanostatic anodization of titanium–II. Reactions efficiencies and electrochemical behaviour model. Electrochim Acta. 1988;33(11):1551–9.10.1016/0013-4686(88)80224-X ↗
21. Curran JA, Clyne TW. Porosity in plasma electrolytic oxide coatings. Acta Mater. 2006;54(7):1985–93.10.1016/j.actamat.2005.12.029 ↗
22. Delplancke JL, Winand R. Galvanostatic anodization of titanium-I. Structures and compositions of the anodic films. Electrochim Acta. 1988;33(11):1539–49.10.1016/0013-4686(88)80223-8 ↗
23. Webster TJ, Siegel RW, Bizios R. Osteoblast adhesion on nanophase ceramics. Biomaterials. 1999;20(13):1221–7.10.1016/S0142-9612(99)00020-4 ↗
24. Velten D, Biehl V, Aubertin F, Valeske B, Possart W, Breme J. Preparation of TiO2 layers on cp–Ti and Ti6Al4 V by thermal and anodic oxidation and by sol–gel coating techniques and their characterization. J Biomed Mater Res. 2002;59(1):18–28.10.1002/jbm.1212 ↗
25. Rosemount Analytical I. Conductance data for commonly used chemicals. Fisher-Rosemount; 1994.
26. Oh H-J, Lee J-H, Jeong Y, Kim Y-J, Chi C-S. Microstructural characterization of biomedical titanium oxide film fabricated by electrochemical method. Surf Coat Technol. 2005;198:247–52.10.1016/j.surfcoat.2004.10.029 ↗
27. Gopal J, Tata BVR, George RP, Muraleedharan P, Dayal RK. Biofouling control of titanium by microroughness reduction. Surf Eng. 2008;24(6):447–51.10.1179/174329408X326344 ↗