Abstract

Acrylic bone cements are widely used in total joint arthroplasties to grout the prosthesis to bone. The changes in the tensile properties and fracture toughness of polymethylmethacrylate (PMMA) bone cements obtained by the addition of control and heat treated short titanium fibers are studied. Heat treatment of titanium fibers is conducted to precipitate titania particles on the fiber surface, which may improve the biocompatibility of the metal. Control (non-heat treated) and heat treated short titanium fibers (250 microm long and 20microm diameter) were used as reinforcements at 3 volume %. X-ray diffraction indicated the presence of a rutile form of titania due to the heat treatments. Results indicate that the tensile and fracture properties of unfilled bone cement were improved by the addition of control and heat-treated fibers. The fracture properties of bone cements reinforced with control titanium fibers were at least 10% higher than those reinforced with heat treated titanium fibers. Therefore, we recommend further studies on the use of non-heat treated titanium fibers to reinforce acrylic bone cement.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Evolution and Science Education · Classical Philosophy and Thought

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (26)

Show source-provided references
1. W. KRAUSE AND R. S. MATHIS J Biomed Mat Res. 22 (A1) (1988) 37–53.
2. G. LEWIS J Biomed Mat Res. 38 (2) (1997) 155–182.10.1002/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C ↗
3. J.GRAHAM, L. PRUITT, M. RIES AND N. GUNDIAH Journal of Arthroplasty. 15 (8) (2000) 1028–1035.10.1054/arth.2000.8188 ↗
4. LEWIS G AND MLADSI S.Biomaterials. 19 (1-3) (1998) 117– 124.10.1016/S0142-9612(97)00165-8 ↗
5. K. -D. KUHN “Bone Cements: Up-to-date comparison of physical and chemical properties of commercial materials.”New York: Springer; 2000.10.1007/978-3-642-59762-6 ↗
6. B. POURDEYHIMI, H. D. WAGNER AND P. SCHWARTZ, J Mat Sci. 21 (1986) 4468–4474.10.1007/BF01106573 ↗
7. B. POURDEYHIMI AND H. D. WAGNER. J Biomed Mat Res. 23 (1989) 63–80.10.1002/jbm.820230106 ↗
8. B. POURDEYHIMI, Y. ULCAY AND H. D. WAGNER. In: Thirteenth Annual Energy Sources Technology Conference and Exhibition; 1990; New Orleans, LA, USA: ASME, NY; 1990.
9. H. Y. KIM AND H. K. YASUDA, J Biomed Mat Res. 48 (2) (1999) 135–142.10.1002/(SICI)1097-4636(1999)48:2<135::AID-JBM7>3.0.CO;2-6 ↗
10. S. SAHA AND S. PAL, J Biomed Mat Res. 17 (6) (1983) 1041–1047.10.1002/jbm.820170613 ↗
11. S. SHINZATO, M. KOBAYASHI, W. F. MOUSA, M. KAMIMURA, M. NEO AND KITAMURA, J Biomed Mat Res. 51 (2) (2000) 258–272.10.1002/(SICI)1097-4636(200008)51:2<258::AID-JBM15>3.0.CO;2-S ↗
12. YS. KIM, YH. KANG, JK. KIM AND JB. PARK, Biomed Mat Eng. 4 (1994) 37–46.
13. GILBERT J. L, NET S. S AND LAUTHENSCHLAGER E. P.Biomaterials. 16 (1995) 1043–1055.10.1016/0142-9612(95)98900-Y ↗
14. L. D. T. TOPOLESKI, P. DUCHEYNE AND J. M. CUCKLER, J Biomed Mat Res. 26 (1992) 1599–1617.10.1002/jbm.820261206 ↗
15. TOPOLESKI L. D. T, DUCHEYNE P AND CUCKLER J. M.Biomaterials. 19 (17) (1998) 1569–1577.10.1016/S0142-9612(97)00117-8 ↗
16. CI. VALLO J Biomed Mat Res. 53 (2000) 717–727.10.1002/1097-4636(2000)53:6<717::AID-JBM15>3.0.CO;2-H ↗
17. M. ABBOUD, L. CASAUBIEILH, F. MORVAN, M. FONTANILLE AND E. DUGUET, J Biomed Mat Res. 53 (6) (2000) 728–736.10.1002/1097-4636(2000)53:6<728::AID-JBM16>3.0.CO;2-A ↗
18. M. M. VILA, M. P. GINEBRA, F. J. GIL AND J. A. PLANELL, J. Biomed Mat Res: App Biomat. 48 (1999) 121–127.10.1002/(SICI)1097-4636(1999)48:2<121::AID-JBM5>3.0.CO;2-P ↗
19. S. P. KOTHA, J. J. MASON, S. R. SCHMID, C. LI, S. CHARLEBOIS AND M. HAWKINS Submitted: Composites A.
20. R. SUZUKI J. A. FRANGOS Clin Ortop Rel Res. 372 (2000) 280–289.10.1097/00003086-200003000-00031 ↗
21. S. MANDL, D. KRAUSE, G. THORWARTH, R. SADER, F. ZEILHOFER, HH. HORCH AND B. RAUSCHENBACH, Surf Coat Tech. 142 (2001) 1046–1050.10.1016/S0257-8972(01)01066-0 ↗
22. E399-90. Standard test method for plane-strain fracture toughness of metallic materials. In: Annual Book of ASTM Standards 03 (01) (2000) 431–452.
23. S. P. KOTHA, C. LI, S. R. SCHMID AND J. J. MASON Accepted: J Biomed Mat Res.
24. D. VELTEN, V. BIEHL, F. AUBERTIN, B. VALESKE, W. POSSART AND J. BREME, J Biomed Mat Res. 59 (1) (2002) 18–28.10.1002/jbm.1212 ↗
25. F. A. AKIN, H. ZREIQAT, S. JORDAN, M. B. J. WIJESUNDARA AND L. HANLEY, J Biomed Mat Res. 57 (4) (2001) 588–596.10.1002/1097-4636(20011215)57:4<588::AID-JBM1206>3.0.CO;2-Y ↗
26. S. M. KENNY AND M. BUGGY, J Mat Sci: Mat in Med. 14 (11) (2003) 923–938.