Tissue biocompatibility of new biodegradable drug-eluting stent materials
Source abstract
Abstract
Drug-eluting stents are a recent innovation for endovascular and endourethral purposes. The aim of this study was to assess the biocompatibility of new biodegradable drug-eluting stent materials in vivo. Rods made of SR-PLDLA (self-reinforced poly-96L,4D: -lactic acid) covered with P(50L/50D)LA and rods made of 96L/4D SR-PLA and covered with P(50L/50D)LA including indomethacin 3.3 microg/mm(2)or dexamethasone 1.5 microg/mm(2), were inserted into the dorsal muscles of 20 rabbits serving as test animals. Rods made of silicone and organotin-positive polyvinylchloride were used as negative and positive controls. The animals were sacrificed after 1 week, 1 month, 2 months or 4 months. Histological changes attributable to the operative trauma were seen in all specimens at 1 week and 1 month. At 2 months both dexamethasone and indomethacin induced less fibrosis than the plain SR-PLDLA covered with P(50L/50D)LA without drug. At 4 months dexamethasone induced both chronic inflammatory changes and foreign body reaction, whereas the reactions in the indomethacin and drug-free plain SR-PLDLA groups were insignificant. The new biodegradable drug-eluting stent materials are highly biocompatible. Drug-eluting biodegradable stents may offer a promising new treatment modality for vascular and urethral diseases. However, further studies are needed to demonstrate their feasibility and efficacy.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Aortic aneurysm repair treatments · Infectious Aortic and Vascular Conditions · Peripheral Artery Disease Management
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (28)
Show source-provided references
1. M. R. BENNET, Coron. Dis. 89 (2003) 218
2. S. T. LAROIA and A. T. LAROIA, Cardiol. Rev. 12(1) (2004) 3710.1097/01.crd.0000090893.66550.9d ↗
3. M. C. MORICE et al., N. Engl. J. Med. 346(23) (2002) 177310.1056/NEJMoa012843 ↗
4. A. COLOMBO et al., Circulation 108 (2003) 78810.1161/01.CIR.0000086926.62288.A6 ↗
5. M. TALJA et al., J. Endourol. 11 (1997) 110.1089/end.1997.11.391 ↗
6. D. E. CUTRIGHT et al., Oral. Surg. 37 (1974) 14210.1016/0030-4220(74)90171-6 ↗
7. P. TÖRMÄLÄ, Clin. Mater. 10 (1992) 2910.1016/0267-6605(92)90081-4 ↗
8. T. Välimaa and P. Törmälä, 1998, Stenting the urinary system (Oxford: Isis Medical Media Ltd), p. 53
9. T. VÄLIMAA and S. LAAKSOVIRTA, Biomaterials 25 (2004) 122510.1016/j.biomaterials.2003.08.072 ↗
10. H. TAMAI et al., Circulation 102(4) (2000) 39910.1161/01.CIR.102.4.399 ↗
11. T. ISOTALO et al., J. Urol. 160 (1998) 203310.1016/S0022-5347(01)62236-5 ↗
12. T. ISOTALO et al., J. Endourol. 16 (2002) 75910.1089/08927790260472926 ↗
13. M. TALJA et al., J. Urol. 154 (1995) 208910.1016/S0022-5347(01)66702-8 ↗
14. A. PETAS et al., J. Urol. 157 (1997) 17310.1016/S0022-5347(01)65316-3 ↗
15. A. Petas et al., Br. J. Urol. 80 (1997) 43910.1046/j.1464-410X.1997.00308.x ↗
16. K. TSUJI et al., Int. J. Cardiovasc. Interv. 5(1) (2003) 1310.1080/14628840304609 ↗
17. Biological evaluation of medical devices. Part 6. Tests for local effects after implantation (1994) ISO 10993-6
18. Biological evaluation of medical devices. Part 5. Tests for in vitro cytotoxicity, 1999, ISO 10993-5
19. I. UURTO et al., J Endovasc Therapy. 10 (2003) 1110
20. Biological evaluation of medical devices. Part 1. Evaluation and testing, 2003, ISO 10993-1
21. T. ISOTALO et al., Urol. Res. 27 (1999) 14910.1007/s002400050101 ↗
22. T. ISOTALO et al., J. Endourol.. 13(7) 1999 52510.1089/end.1999.13.525 ↗
23. G. BROOKS et al., J. Pharm. Pharmacol. 55 (2003) 51910.1211/002235702775 ↗
24. E. P. STRECKER et al., Cardiovasc. Interv. Radiol. 21(6) (1998) 48710.1007/s002709900309 ↗
25. A. M. LINCOFF et al., J. Am. Coll. Cardiol. 29(4) (1997) 80810.1016/S0735-1097(96)00584-0 ↗
26. X. LIU et al., Catheter. Cardiovasc. Interv. 60(2) (2003) 17210.1002/ccd.10636 ↗
27. Biological evaluation of medical devices. Part 12. Sample preparation and reference material, 2002, ISO 10993-12
28. S. LAAKSOVIRTA et al., J. Urol. 167 (2002) 152710.1016/S0022-5347(05)65357-8 ↗