Biocompatibility studies of low temperature nitrided and collagen-I coated AISI 316L austenitic stainless steel
Source abstract
Abstract
The biocompatibility of austenitic stainless steels can be improved by means of surface engineering techniques. In the present research it was investigated if low temperature nitrided AISI 316L austenitic stainless steel may be a suitable substrate for bioactive protein coating consisting of collagen-I. The biocompatibility of surface modified alloy was studied using as experimental model endothelial cells (human umbilical vein endothelial cells) in culture. Low temperature nitriding produces modified surface layers consisting mainly of S phase, the supersaturated interstitial solid solution of nitrogen in the austenite lattice, which allows to enhance surface microhardness and corrosion resistance in PBS solution. The nitriding treatment seems to promote the coating with collagen-I, without chemical coupling agents, in respect of the untreated alloy. For biocompatibility studies, proliferation, lactate dehydrogenase levels and secretion of two metalloproteinases (MMP-2 and MMP-9) were determined. Experimental results suggest that the collagen protection may be favourable for endothelial cell proliferation and for the control of MMP-2 release.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Metal and Thin Film Mechanics · Orthopaedic implants and arthroplasty · Corrosion Behavior and Inhibition
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (58)
Show source-provided references
1. Wapner KL. Implications of metallic corrosion in total knee arthroplasty. Clin Orthop Relat Res. 1991;271:12–20.10.1097/00003086-199110000-00004 ↗
2. Lo KH, Shek CH, Lai JKL. Recent developments in stainless steels. Mater Sci Eng R. 2009;65:39–104.10.1016/j.mser.2009.03.001 ↗
3. Jacobs AM, Gloff LM. Podiatric metallurgy and the effects of implanted metals on living tissues. Clin Podiatry. 1985;2:121–41.10.1016/S0742-0668(23)00144-9 ↗
4. Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001;83-A:428–36.10.2106/00004623-200103000-00017 ↗
5. Hallab N, Link HD, McAfee PC. Biomaterial optimization in total disc arthroplasty. Spine. 2003;28:139–52.10.1097/01.BRS.0000092214.87225.80 ↗
6. Santin M, Mikhalovska L, Lloyd AW, Mikhalovsky S, Sigfrid L, Denyer SP, Field S, Teer D. In vitro host response assessment of biomaterials for cardiovascular stent manufacture. J Mater Sci. 2004;15:473–7.
7. Hong J, Andersson J, Ekdahl KN, Elgue G, Axen N, Larsson R, Nilsson B. Titanium is a highly thrombogenic biomaterial: possible implications for osteogenesis. Thromb Haemostasis. 1999;82:58–64.10.1055/s-0037-1614630 ↗
8. Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R. Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol. 2006;48:193–202.10.1016/j.jacc.2006.03.042 ↗
9. Yuan Y, Liu C, Yin M. Plasma polymerized n-butyl methacrylate coating with potential for re-endothelialization of intravascular stent devices. J Mater Sci Mater Med. 2008;19:2187–96.10.1007/s10856-007-3319-8 ↗
10. Yeh H-I, Lu S-K, Tian T-Y, Hong R-C, Lee W-H, Tsai C-H. Comparison of endothelial cells grown on different stent materials. J Biomed Mater Res. 2006;76A:835–41.10.1002/jbm.a.30595 ↗
11. Kushwaha M, Anderson JM, Bosworth CA, Andukuri A, Minor WP, Lancaster JR Jr, Anderson PG, Brott BC, Jun H-W. A nitric oxide releasing, self assembled peptide amphiphile matrix that mimics native endothelium for coating implantable cardiovascular devices. Biomaterials. 2010;31:1502–8.10.1016/j.biomaterials.2009.10.051 ↗
12. Waterhouse A, Yin Y, Wise SG, Bax DV, McKenzie DR, Bilek MMM, Weiss AS, MKC Ng. The immobilization of recombinant human tropoelastin on metals using a plasma-activated coating to improve the biocompatibility of coronary stents. Biomaterials. 2010;31:8332–40.10.1016/j.biomaterials.2010.07.062 ↗
13. Morra M, Cassinelli C, Cascardo G, Cahalan P, Cahalan L, Fini M, Giardino R. Surface engineering of titanium by collagen immobilization. Surface characterization and in vitro and in vivo studies. Biomaterials. 2003;24:4639–54.10.1016/S0142-9612(03)00360-0 ↗
14. Morra M. Biochemical modification of titanium surfaces: peptides and ECM proteins. Eur Cells Mater. 2006;12:1–15.10.22203/eCM.v012a01 ↗
15. Rammelt S, Schulze E, Bernhardt R, Hanisch U, Scharnweber D, Worch H, Zwipp H, Biewener A. Coating of titanium implants with type-I collagen. J Orthop Res. 2004;22:1025–34.10.1016/j.orthres.2004.02.011 ↗
16. Rammelt S, Illert T, Bierbaum S, Scharnweber D, Zwipp H, Schneiders W. Coating of titanium implants with collagen. RGD peptide and chondroitin sulphate. Biomaterials. 2006;27:5561–71.10.1016/j.biomaterials.2006.06.034 ↗
17. Stadlinger B, Pilling E, Mai R, Bierbaum S, Berhardt R, Scharnweber D, Eckelt U. Effect of biological implant surface coatings on bone formation, applying collagen, proteoglycans, glycosaminoglycans and growth factors. J Mater Sci Mater Med. 2008;19:1043–9.10.1007/s10856-007-3077-7 ↗
18. Hauser J, Koeller M, Bensch S, Halfmann H, Awakowicz P, Steinau H-U, Esenwein S. Plasma mediated collagen-I-coating of metal implant materials to improve biocompatibility. J Biomed Mater Res. 2010;94A:12–26.10.1002/jbm.a.32672 ↗
19. Chen JL, Li QL, Chen JY, Chen C, Huang N. Improving blood-compatibility of titanium by coating collagen-heparin multilayers. Appl Surf Sci. 2009;255:6894–900.10.1016/j.apsusc.2009.03.011 ↗
20. Chen J, Chen C, Chen Z, Chen J, Li Q, Huang N. Collagen/heparin coating on titanium surface improves the biocompatibility of titanium applied as a blood-contacting biomaterial. J Biomed Mater Res. 2010;95A:341–9.10.1002/jbm.a.32847 ↗
21. Lampman S. Introduction to surface hardening of steels. In: ASM handbook, vol 4. Materials Park: ASM International; 1997. pp. 259–67.
22. Bell T. Surface engineering of austenitic stainless steel. Surf Eng. 2002;18:415–22.10.1179/026708402225006268 ↗
23. Dong H. S-phase surface engineering of Fe–Cr, Co–Cr and Ni–Cr alloys. Int Mater Rev. 2010;55:65–98.10.1179/095066009X12572530170589 ↗
24. Fossati A, Galvanetto E, Bacci T, Borgioli F. Improvement of corrosion resistance of austenitic stainless steels by means of glow-discharge nitriding. Corros Rev. 2011;29:209–21.10.1515/CORRREV.2011.004 ↗
25. Stetler-Stevenson WG. Matrix metalloproteinases in angiogenesis: a moving target for therapeutic intervention. J Clin Investig. 1999;103:1237–41.10.1172/JCI6870 ↗
26. Nguyen M, Arkell J, Jackson CJ. Human endothelial gelatinases and angiogenesis. Int J Biochem Cell Biol. 2001;33:960–70.10.1016/S1357-2725(01)00007-3 ↗
27. Spinale FG. Matrix metalloproteinases: regulation and dysregulation in the failing heart. Circ Res. 2002;90:520–30.10.1161/01.RES.0000013290.12884.A3 ↗
28. Borgioli F, Fossati A, Galvanetto E, Bacci T, Pradelli G. Glow-discharge nitriding of AISI 316L austenitic stainless steel: influence of treatment pressure. Surf Coat Technol. 2006;200:5505–13.10.1016/j.surfcoat.2005.07.073 ↗
29. Lutterotti L, Matthies S, Wenk H-R. Material analysis using diffraction (MAUD): a user friendly java program for Rietveld texture analysis and more. In: Szpunar JA, editor. Proceedings of the 12th international conference on textures of materials (ICOTOM-12), vol 1. Ottawa: NRC; 1999. pp 1599–604.
30. Kalogeris TJ, Kevil CG, Laroux FS, Coe LL, Phifer TJ, Alexander JS. Differential monocyte adhesion and adhesion molecule expression in venous and arterial endothelial cells. Am J Physiol. 1999;276:L9–19.10.1152/ajpcell.1999.276.4.C856 ↗
31. Singh V, Marchev K, Cooper CV, Meletis EI. Intensified plasma-assisted nitriding of AISI 316L stainless steel. Surf Coat Technol. 2002;160:249–58.10.1016/S0257-8972(02)00403-6 ↗
32. Xu X, Yu Z, Wang L, Qiang J, Hei Z. Phase depth distribution characteristics of the plasma nitrided layer on AISI 304 stainless steel. Surf Coat Technol. 2003;162:242–7.10.1016/S0257-8972(02)00670-9 ↗
33. Shahryari A, Omanovic S, Szpunar JA. Enhancement of biocompatibility of 316LVM stainless steel by cyclic potentiodynamic polarization. J Biomed Mater Res. 2008;89A:1049–62.10.1002/jbm.a.32053 ↗
34. Abreu CM, Cristóbal MJ, Merino P, Nóvoa XR, Pena G, Pérez MC. Electrochemical behaviour of an AISI 304L stainless steel implanted with nitrogen. Electrochem Acta. 2008;53:6000–7.10.1016/j.electacta.2008.03.064 ↗
35. Valero Vidal C, Igual Muñoz A. Electrochemical characterisation of biomedical alloys for surgical implants in simulated body fluids. Corr Sci. 2008;50:1954–61.10.1016/j.corsci.2008.04.002 ↗
36. Jiang S, Ma X, Sun Y, Sun M. Corrosion behaviour of AISI 302 steel treated by elevated temperature nitrogen plasma immersion ion implantation. Scripta Mater. 2005;53:1427–32.10.1016/j.scriptamat.2005.08.015 ↗
37. Anandan C, William Grips VK, Ezhil Selvi V, Rajam KS. Electrochemical studies of stainless steel implanted with nitrogen and oxygen by plasma immersion ion implantation. Surf Coat Technol. 2007;201:7873–9.10.1016/j.surfcoat.2007.03.034 ↗
38. Navarro-Flores E, Chong Z, Omanovic S. Characterization of Ni, NiMo, NiW and NiFe electroactive coatings as electrocatalysts for hydrogen evolution in an acidic medium. J Mol Catal A. 2005;226:179–97.10.1016/j.molcata.2004.10.029 ↗
39. Martinesi M, Bruni S, Stio M, Treves C, Bacci T, Borgioli F. Biocompatibility evaluation of surface-treated AISI 316L austenitic stainless steel in human cell cultures. J Biomed Mater Res. 2007;80A:131–45.10.1002/jbm.a.30846 ↗
40. Bordji K, Jouzeau J-Y, Mainard D, Payan E, Delagoutte J-P, Netter P. Evaluation of the effect of three surface treatments on the biocompatibility of 316L stainless steel using human differentiated cells. Biomaterials. 1996;17:491–500.10.1016/0142-9612(96)82723-2 ↗
41. Arslan E, Iğdil MC, Yazici H, Tamerler C, Bermek H, Trabzon L. Mechanical properties and biocompatibility of plasma-nitrided laser-cut 316L cardiovascular stents. J Mater Sci. 2008;19:2079–86.
42. Buhagiar J, Bell T, Sammons R, Dong H. Evaluation of the biocompatibility of S-phase layers on medical grade austenitic stainless steels. J Mater Sci. 2011;22:1269–78.
43. Lin Y-H, Lan W-C, Ou K-L, Liu C-M, Peng P-W. Hemocompatibility evaluation of plasma-nitrided austenitic stainless steels at low temperature. Surf Coat Technol. 2012;206:4785–90.10.1016/j.surfcoat.2012.03.089 ↗
44. Lei MK. Phase transformations in plasma source ion nitrided austenitic stainless steel at low temperature. J Mater Sci. 1999;34:5975–82.10.1023/A:1004728711459 ↗
45. Borgioli F, Fossati A, Raugei L, Galvanetto E, Bacci T. Low temperature glow-discharge nitriding of stainless steels. In: Proceedings of the 7th European stainless steel conference—science and market, 21–23 Sept 2011, Como, Associazione Italiana di Metallurgia, Milano, 2011(CD-rom; ISBN: 978-88-85298-84-2).
46. Yau YH, Yang K, Zhang B. Pitting corrosion resistance of La added 316L stainless steel in simulated body fluid. Mater Lett. 2007;61:1154–7.10.1016/j.matlet.2006.06.071 ↗
47. Hanawa T, Hiromoto S, Yamamoto A, Kuroda D, Asami K. XPS Characterization of the surface oxide film of 316L stainless steel samples that were located in quasi-biological environments. Mater Trans. 2002;43:3088–92.10.2320/matertrans.43.3088 ↗
48. Bruni S, Martinesi M, Stio M, Treves C, Bacci T, Borgioli F. Effects of surface treatment of Ti-6Al-4V titanium alloy on biocompatibility in cultured human umbilical vein endothelial cells. Acta Biomater. 2005;1:223–34.10.1016/j.actbio.2004.11.001 ↗
49. Shahryari A, Azari F, Vali H, Omanovic S. The response of fibrinogen, platelets, endothelial and smooth muscle cells to an electrochemically modified SS316LS surface: towards the enhanced biocompatibility of coronary stents. Acta Biomater. 2010;6:695–701.10.1016/j.actbio.2009.07.007 ↗
50. Haslam G, Wyatt D, Kitos PA. Estimating the number of viable animal cells in multi-well cultures based on their lactate dehydrogenase activities. Cytotechnology. 2000;32:63–75.10.1023/A:1008121125755 ↗
51. Yan C, Boyd DD. Regulation of matrix metalloproteinase gene expression. J Cell Physiol. 2007;211:19–26.10.1002/jcp.20948 ↗
52. Chow AK, Cena J, Schulz R. Acute actions and novel targets of matrix metalloproteinases in the heart and vasculature. Br J Pharmacol. 2007;152:189–205.10.1038/sj.bjp.0707344 ↗
53. Ho FM, Liu SH, Lin WW, Liau CS. Opposite effects of high glucose on MMP-2 and TIMP-2 in human endothelial cells. J Cell Biochem. 2007;101:442–50.10.1002/jcb.21192 ↗
54. Cavdar Z, Oktay G, Egrilmez MY, Genc S, Genc K, Altun Z, Islekel H, Guner G. In vitro reoxygenation following hypoxia increases MMP-2 and TIMP-2 secretion by human umbilical vein endothelial cells. Acta Biochim Pol. 2010;57:69–73.10.18388/abp.2010_2374 ↗
55. Izidoro-Toledo TC, Guimaraes DA, Belo VA, Gerlach RF, Tanus-Santos JE. Effects of statins on matrix metalloproteinases and their endogenous inhibitors in human endothelial cells. Naunyn-Schmied Arch Pharmacol. 2011;383:547–54.10.1007/s00210-011-0623-0 ↗
56. Nagase H, Visse R, Murphy G. Structure and function of matrix metalloproteinases and TIMPs. Cardiovasc Res. 2006;69:562–73.10.1016/j.cardiores.2005.12.002 ↗
57. Goser S, Andrassy M, Buss SJ, Leuschner F, Volz CH, Otti R, Zittrich S, Blaudeck N, Hardt SE, Pfitzer G, Rose NR, Katus HA, Kaya Z. Cardiac troponin I but not cardiac troponin T induces severe autoimmune inflammation in the myocardium. Circulation. 2006;114:1693–702.10.1161/CIRCULATIONAHA.106.635664 ↗
58. Li YY, McTiernan CF, Feldman AM. Proinflammatory cytokines regulate tissue inhibitors of metalloproteinases and disintegrin metalloproteinase in cardiac cells. Cardiovasc Res. 1999;42:162–72.10.1016/S0008-6363(98)00297-1 ↗