journal article·2012-02

An experimental study of electrochemical polishing for micro-electro-discharge-machined stainless-steel stents

Derry Lappin, Abdolreza Rashidi Mohammadi, Kenichi Takahata

Publisher page

Abstract

This paper reports electrochemical polishing (EP) of 316L stainless-steel structures patterned using micro-electro-discharge machining (μEDM) for application to stents including intelligent stents based on micro-electro-mechanical-systems technologies. For the process optimization, 10 μm deep cavities μEDMed on the planar material were polished in a phosphoric acid-based electrolyte with varying current densities and polishing times. The EP condition with a current density of 1.5 A/cm(2) for an EP time of 180 s exhibited the highest surface quality with an average roughness of 28 nm improved from~400 nm produced with high-energy μEDM. The EP of μEDMed surfaces was observed to produce almost constant smoothness regardless of the initial roughness determined by varying discharge energies. Energy-dispersive X-ray spectroscopy was performed on the μEDMed surfaces before and after EP. A custom rotational apparatus was used to polish tubular test samples including stent-like structures created using μEDM, demonstrating uniform removal of surface roughness and sharp edges from the structures.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Advanced Machining and Optimization Techniques · Advanced Surface Polishing Techniques · Advanced machining processes and optimization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (33)

Show source-provided references
1. Logan AG, Bradley D. Sleep apnea and cardiovascular disease. Curr Hypertens Rep. 2010;12:182–8.10.1007/s11906-010-0107-5 ↗
2. Al-Suwaidi J, Berger PB, Holmes DR. Coronary artery stents. JAMA. 2000;284(14):1828–36.10.1001/jama.284.14.1828 ↗
3. Al-Mubarak N, Iyer SS. Carotid artery stenting for the high surgical risk patients. J Cardiovasc Surg. 2005;46(1):1–8.
4. Cullen SN, Chapman RW. Review article: Current management of primary sclerosing cholangitis. Alimentary Pharmacol Therap. 2005;21(8):933–48.10.1111/j.1365-2036.2005.02407.x ↗
5. Monkemuller KE, Kahl S, Malfertheiner P. Endoscopic therapy of chronic pancreatitis. Dig Dis. 2004;22(3):280–91.10.1159/000082800 ↗
6. Saito Y, Imamura H. Airway stenting. Surg Today. 2005;35(4):265–70.10.1007/s00595-004-2942-y ↗
7. Carrau RL. Use of stents in head and neck surgery. Curr Opin Otolaryngol Head Neck Surg. 2005;13(2):105–6.10.1097/01.moo.0000156160.82671.0a ↗
8. Bertand OF, Sipehia R, Mongrain R, Rodes J, Tardif J, Bilodeau L, Cote G, Bourassa MG. Biocompatibility aspects of new stent technology. J Am Coll Cardiol. 1998;32:562–71.10.1016/S0735-1097(98)00289-7 ↗
9. Kathuria YP. Laser microprocessing of metallic stent for medical therapy. J Mater Process Technol. 2005;170(3):545–50.10.1016/j.jmatprotec.2005.05.041 ↗
10. Momma C, Knop U, Nolte S. Laser cutting of slotted tube coronary stents—state-of-the-art and future developments. Prog Biomed Res. 1999;4(1):39–44.
11. Raval A, Choubey A, Engineer C, Kothwala D. Development and assessment of 316LVM cardiovascular stent. Mater Sci Eng A. 2004;386(1–2):331–43.10.1016/S0921-5093(04)00974-8 ↗
12. Masaki T, Kawata K, Masuzawa T. Micro electro-discharge machining and its applications. Proc. IEEE Int. Workshop on MicroElectro Mechanical Systems (MEMS ’90). Napa Valley, California; 1990. p. 21–26.10.1109/MEMSYS.1990.110240 ↗
13. Takahata K. Micro-electro-discharge machining technologies for MEMS. In Takahata K,editor. Micro electronic and mechanical systems. IN-TECH; 2009 p. 143–164.10.5772/7009 ↗
14. Takahata K, Gianchandani YB. A planar approach for manufacturing cardiac stents: design, fabrication, and mechanical evaluation. J Microelectromech Syst. 2004;13:933–9.10.1109/JMEMS.2004.838357 ↗
15. Takahata K, Gianchandani YB, Wise KD. Micromachined antenna stents and cuffs for monitoring intraluminal pressure and flow. J Microelectromech Syst. 2006;15:1289–98.10.1109/JMEMS.2006.880229 ↗
16. Green SR, Gianchandani YB. Wireless magnetoelastic monitoring of biliary stents. J Microelectromech Syst. 2009;18(1):64–78.10.1109/JMEMS.2008.2008568 ↗
17. Hocheng H, Kao PS, Chen YF. Electropolishing of 316L stainless steel for anticorrosion passivation. J Mater Eng Perform. 2001;10:414–8.10.1361/105994901770344827 ↗
18. Lee ES. Machining characteristics of the electropolishing of stainless steel (STS316L). Int J Adv Manuf Technol. 2000;16:591–9.10.1007/s001700070049 ↗
19. Kao PS, Hocheng H. Optimization of electrochemical polishing of stainless steel by grey relational analysis. J Mater Process Technol. 2003;140:255–9.10.1016/S0924-0136(03)00747-7 ↗
20. Abbott AP, Capper G, McKenzie KJ, Ryder KS. Voltammetric and impedance studies of the electropolishing of type 316 stainless steel in a choline chloride based ionic liquid. Electrochim Acta. 2006;51:4420–5.10.1016/j.electacta.2005.12.030 ↗
21. Chen SC, Tu GC, Huang CA. The electrochemical polishing behavior of porous austenitic stainless steel (AISI 316L) in phosphoric-sulfuric mixed acids. Surf Coat Technol. 2005;200:2065–71.10.1016/j.surfcoat.2005.06.008 ↗
22. Scheerder ID, Sohier J, Verbeken E, Froyen L, Humbeeck JV. Biocompatibility of coronary stent materials: effect of electrochemical polishing. Materialwissenschaft und Werkstofftechnik. 1999;32(2):142–8.10.1002/1521-4052(200102)32:2<142::AID-MAWE142>3.0.CO;2-N ↗
23. Haiıdopoulos M, Turgeon S, Sarra-Bournet C, Laroche G, Mantovani D. Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications. J Mater Sci: Mater Med. 2006;17:647–57.10.1007/s10856-006-9228-4 ↗
24. Zhao H, Humbeeck JV, Sohier J, Scheerder IV. Electrochemical polishing of 316L stainless steel slotted tube coronary stents. J Mater Sci: Mater Med. 2002;13:911–6.10.1023/A:1019831808503 ↗
25. Bhuyan A, Gregory B, Lei H, Yee SY, Gianchandani YB. Pulse and DC electropolishing of stainless steel for stents and other devices. IEEE Sensors, Irvine, California; 2005 p. 314–317.10.1109/ICSENS.2005.1597699 ↗
26. Fleischer J, Masuzawa T, Schmidt J, Knoll M. New applications for micro-EDM. J Mater Process Technol. 2004;149:246–9.10.1016/j.jmatprotec.2004.02.012 ↗
27. Kwok SCH, Wang J, Chu PK. Surface energy, wettability, and blood compatibility phosphorus doped diamond-like carbon films. Diam Relat Mater. 2005;14:78–85.10.1016/j.diamond.2004.07.019 ↗
28. Zhou J, Yun J, Zang XP, Shen J, Lin SC. Platelet adhesion and protein adsorption on silicone rubber surface by ozone-induced grafted polymerization with carboxybetaine monomer. Colloid Surface B. 2005;41:55–62.10.1016/j.colsurfb.2004.11.006 ↗
29. Wootton DM, Ku DN. Fluid mechanics of vascular systems, diseases, and thrombosis. Annu Rev Biomed Eng. 1999;1:299–329.10.1146/annurev.bioeng.1.1.299 ↗
30. Tsunoda N, Kokubo K, Sakai K, Fukuda M, Miyazaki M, Hiyoshi T. Surface roughness of cellulose hollow fiber dialysis membranes and platelet adhesion. ASAIO J. 1999;45:418–23.10.1097/00002480-199909000-00010 ↗
31. Hecker JF, Scandrett LA. Roughness and thrombogenicity of the outer surfaces of intravascular catheters. J Biomed Mater Res. 1985;19:381–95.10.1002/jbm.820190404 ↗
32. Zingg W, Neumann AW, Strong AB, Hum OS, Absolom DR. Effect of surface roughness on platelet adhesion under static and under flow conditions. Can J Surg. 1982;25:16–9.
33. Wong YS, Rahman M, Lim HS, Han H, Ravi N. Investigation of micro-EDM material removal characteristics using single RC-pulse discharges. J Mater Process Technol. 2003;140:303–7.10.1016/S0924-0136(03)00771-4 ↗