journal article·2007-08-07

Fatigue crack propagation under variable amplitude loading in PMMA and bone cement

S. L. Evans

Publisher page

Abstract

Fatigue failure of PMMA bone cement is an important factor in the failure of cemented joint replacements. Although these devices experience widely varying loads within the body, there has been little or no study of the effects of variable amplitude loading (VAL) on fatigue damage development. Fatigue crack propagation tests were undertaken using CT specimens made from pure PMMA and Palacos R bone cement. In PMMA, constant amplitude loading tests were carried out at R- ratios ranging from 0.1 to 0.9, and VAL tests at R = 0.1 with 30% overloads every 100 cycles. Palacos R specimens were tested with and without overloads every 100 cycles and with a simplified load spectrum representing daily activities. The R- ratio had a pronounced effect on crack propagation in PMMA consistent with the effects of slow crack growth under constant load. Single overloads caused pronounced crack retardation, especially at low da/dN. In Palacos R, similar overloads had little effect, whilst individual overloads at low da/dN caused pronounced acceleration and spectrum loading retarded crack growth relative to Paris Law predictions. These results demonstrate that VAL can have dramatic effects on crack growth, which should be considered when testing bone cements.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Orthopaedic implants and arthroplasty · Total Knee Arthroplasty Outcomes · Bone fractures and treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (25)

Show source-provided references
1. A. FAULKNER, L. G. KENNEDY, K. BAXTER, J. DONOVAN, M. WILKINSON and G. BEVAN, Health Technol. Assess. 2(6) (1998) 110.3310/hta2060 ↗
2. M. JASTY, W. J. MALONEY, C. R. BRAGDON, D. O. O’CONNOR, T. HAIRE and W. H. HARRIS, J. Bone Joint Surg. 73B(4) (1991) 55110.1302/0301-620X.73B4.2071634 ↗
3. P. Erani, P. Savigni, L. Cristofolini and M. Viceconti, In Proc. of the European Society of Biomechanics, ‘s-Hertogenbosch, Holland, July 2004
4. P. ASPENBERG and H. VANDERVIS, Acta Orthop. Scand. 69(1) (1998) 110.3109/17453679809002344 ↗
5. S. K. BHAMBRI and L. N. GILBERTSON, J. Biomed. Mat. Res. 29 (1995) 23310.1002/jbm.820290214 ↗
6. S. P. JAMES, M. JASTY, J. DAVIES, H. PIEHLER and W. H. HARRIS, J. Biomed. Mat. Res. 26 (1992) 65110.1002/jbm.820260507 ↗
7. N. DUNNE, J. F. ORR, M. T. MUSHIPE and R. J. EVELEIGH, Biomaterials 24 (2003) 23910.1016/S0142-9612(02)00296-X ↗
8. J. P. DAVIES and W. H. HARRIS, Clin. Orthop. Rel. Res. 254 (1990) 26110.1097/00003086-199005000-00040 ↗
9. G. LEWIS, S. JANNA and M. CARROLL, Biomaterials 24 (2003) 111110.1016/S0142-9612(02)00437-4 ↗
10. M. BALEANI, L. CRISTOFOLINI, C. MINARI and A. TONI, Proc. Instn. Mech. Engrs., Part H, J. Eng. Med. 217(1) (2003) 910.1243/095441103762597683 ↗
11. G. LEWIS, J. Biomed. Mat. Res. 66B(1) (2003) 45710.1002/jbm.b.10018 ↗
12. L. CRISTOFOLINI, A. S. TEUTONICO, L. MONTI, A. CAPPELLO and A. TONI, J. Biomech. 36(11) (2003) 160310.1016/S0021-9290(03)00191-X ↗
13. C. M. RIMNAC, T. M. WRIGHT and D. L. MCGILL, J. Bone Joint Surg. 68A (1986) 28110.2106/00004623-198668020-00014 ↗
14. N. C. NGUYEN, W. J. MALONEY and R. H. DAUSKARDT, J. Mat. Sci.: Mater. Med. 8(8) (1997) 473
15. S. ISHIHARA, A. J. MCEVILY, T. GOSHIMA, K. KANEKASU and T. NARA, J. Mat. Sci.: Mater. Med. 11(10) (2000) 661
16. J. M. MANERO, M. P. GINEBRA, F. J. GIL, J. A. PLANELL, J. A. DELGADO, L. MOREJON, A. ARTOLA, M. GURRUCHAGE and I. GONI, Proc. Instn. Mech. Engrs., Part H, J. Eng. Med. 218 (2004) 16710.1243/095441104323118888 ↗
17. S. SCHMITT, D. J. KRZYPOW and C. M. RIMNAC, Biomed. Tech. (Berl.) 49(3) (2004) 6110.1515/BMT.2004.012 ↗
18. E. Piazza, M. Baleani, L. Cristofolini and A. Toni, In Proc. 12th Conference of the European Society of Biomechanics, Dublin, 2000
19. B. K. C. YUEN and F. TAHERI, Polymer Testing 23(5) (2004) 49110.1016/j.polymertesting.2003.12.005 ↗
20. M. SKORUPA, Fatigue Fract. Engng. Mater. Struct. 22(10) (1999) 90510.1046/j.1460-2695.1999.00158.x ↗
21. C. M. STYLES, S. L. EVANS and P. J. GREGSON, Biomaterials 19 (1998) 105710.1016/S0142-9612(98)00031-3 ↗
22. G. BERGMANN, G. DEURETZBACHER, M. HELLER, F. GRAICHEN, A. ROHLMANN, J. STRAUSS and G. N. DUDA, J. Biomech. 34(7) (2001) 85910.1016/S0021-9290(01)00040-9 ↗
23. P. W. BEAUMONT and R. J. YOUNG, J. Biomed. Mat. Res. 9 (1975) 42310.1002/jbm.820090506 ↗
24. G. C. PULOS and W. G. KNAUSS, Int. J. Fract. 93(1–4) (1998) 16110.1023/A:1007525920089 ↗
25. L. D. T. TOPOLESKI, P. DUCHEYNE and J. M. CUCKLER, Biomaterials 14(15) (1993) 116510.1016/0142-9612(93)90162-U ↗